VII. TROUBLESHOOTING
A.
Machine does not operate:
1. Make sure the parts cleaner is connected to electric power or air supply.
2. Check for incoming power. Check serial plate for power requirements.
3. On electric units: check reset button on GFCI cord to make sure it is not tripped. On air units: an
increase in air supply may be required.
B.
Cleaning fluid not to temperature:
1. Check to make sure heater switch is turned
“ON”.
2. Check fluid level in tank.
3. Check to see if high temperature reset is tripped.
C.
Little or no fluid flow thru the flow-thru brush:
1. Turn pump switch
“ON” or increase air pressure.
2. Check the fluid level in the tank.
3. Check pump intake for obstructions.
MACHINE NOT
FUNCTIONING
PROPERLY
WHAT DOES
NOT WORK?
IS THE
SWITCH ON?
PUMP
IS THE FLUID LEVEL
HIGH ENOUGH TO
SUBMERGE THE
PUMP?
YES
TURN ON THE
SWITCH
NO
ADD FLUID
NO
IS THE FILTER
SCREEN ON THE
PUMP CLOGGED?
YES
CLEAR THE
SCREEN
YES
ARE THE
SWITCHES
ON?
PUMP
&
HEATE
R
TURN ON THE
SWITCHES
NO
IS THE MACHINE
PLUGGED IN TO A
GROUNDED
OUTLET?
YES
PLUG IN THE
MACHINE
NO
IS THERE
POWER TO THE
RECEPTACLE?
YES
APPLY POWER AND
RESET GFCI CORD
NO
IS THE RESET ON
THE GFCI CORD
TRIPPED?
YES
PRESS THE RESET
BUTTON ON THE GFCI
CORD
YES
REPLACE THE
GFCI CORD
IS THE FLUID
TEMPERATURE
ABOVE 120 OR
BELOW 100?
HEATE
R
REPLACE THE
THERMOSTAT
ABOVE
IS THE HEATER
SWITCH ON?
BELOW
TURN ON THE
SWITCH
NO
NO
IS THE HIGH
TEMPERATURE
RESET TRIPPED?
YES
WAS THE FLUID
OVER 120 DEGREES
AT ONE TIME
YES
YES
PRESS THE HIGH
TEMPERATURE
RESET BUTTON
NO
ARE ALL THE
WIRES IN THE
CONTROL BOX
HOOKED UP?
NO
PLUG IN THE
WIRES
NO
REPLACE THE
HEATER
YES
ARE THE VALVES
FOR THE BRUSH
AND SPIGOT OPEN?
NO
OPEN THE
VALVES
NO
CHANGE THE
PUMP
YES