background image

7

Technical Specifications

IPv6 Transitioning

–  RFC 2893 Transition Mechanisms for IPv6 Hosts
 and 

Routers

–  RFC 3056 Connection of IPv6 Domains via IPv4 Clouds

NETWORK MANAGEMENT

–  IronView Network Manager (INM) Web-based graphical
 user 

interface

–  Integrated Standard-based Command Line Interface (CLI)
–  RFC 3176 sFlow 
–  RFC 854 Telnet
–  RFC 2068 HTTP
–  RFC 2578 and 3410 SNMPv2 and v3
–  RFC 1757 RMON Group partial 1, full 2, 3, and 9 
–  HP OpenView for Sun Solaris, HP-UX, IBM’s AIX, 
 

Linux and Windows NT 

–  SNMP MIB II

ELEMENT SECURITY OPTIONS

– AAA
– RADIUS
–  Secure Shell (SSH v2)
–  Secure Copy (SCP)
– TACACS/
–  Username/Password (Challenge and Response)
–  Bi-level Access Mode (Standard and EXEC Level)
–  Protection for Denial of Service attacks, such as TCP SYN 
 

or Smurf Attacks

ENVIRONMENTAL

 

–  Operating Temperature: 0 °C to 40 °C (32 °F to 104 °F)
–  Relative Humidity: 5 to 90%,@40 °C (104 °F),
 non-condensing
–  Operating Altitude: 10,000 ft (3,000 m)
–  Storage Temperature: -25 ºC to 70 ºC (-13 ºF to 158 °F)
–  Storage Humidity: 95% maximum relative humidity,
 non-condensing
–  Storage Altitude: 15,000 ft (4,500 m) maximum

SAFETY AGENCY APPROVALS

–  CAN/CSA-C22.2 No.60950-00/UL 60950—Third 
 

Edition, Safety of Information Technology Equipment

–  EN 60825-1 Safety of Laser Products—Part 1: Equipment
 

Classification, Requirements and User’s Guide

–  EN 60825-2 Safety of Laser Products—Part 2: Safety of
 

Optical Fibre Communication Systems

–  EN 60950 Safety of Information Technology Equipment 

ELECTROMAGNETIC EMISSION 

CERTIFICATION 

–  CSA 950 Electromagnetic Emission Certification
–  FCC Class A
–  EN 55022/CISPR-22 Class A/ VCCI Class A
–  ICES-003 Electromagnetic Emission

IMMUNITY

–  EN 61000-3-2 Power Line Harmonics
–  EN 61000-4-2 ESD
–  EN 61000-4-3 Radiated Immunity
–  EN 61000-4-4 EFT
–  EN 61000-4-5 Surge
–  EN 61000-4-6 Low Frequency Common Immunity
–  EN 61000-4-11 Voltage Dips and Sags Generic: EN50082-1
–  ESD: IEC 61000-4-2; 4 kV CD, 8 kV AD
–  Radiated: IEC 61000-4-3;3 V/m
–  EFT/Burst: IEC 61000-4-4;1.0 kV (power line), 0.5 kV
 (signal 

line)

–  Conducted: IEC 61000-4-6; 3 V

ENVIRONMENTAL REGULATORY 

COMPLIANCE

–  EU 2002/95/EC RoHS (with lead exemption)
–  EU 2002/91/EC WEEE

WARRANTY

– 1-year 

hardware

– 90-day 

software 

MOUNTING OPTIONS

–  19" Universal EIA 310 (Telco) Rack or Tabletop

IEEE COMPLIANCE

–  802.3ae 10-Gigabit Ethernet
–  802.3ab Gigabit Ethernet over Copper
–  802.3x Flow Control
–  802.3ad Link Aggregation
–  802.1Q VLAN Tagging
– 802.1D 

Bridging

–  802.1w Rapid STP
–  802.1s Multiple Spanning Tree Protocol
–  802.1X User authentication
–  802.3 Ethernet Like MIB

RFC COMPLIANCE

BGPv4

–  RFC 4271 BGPv4
–  RFC 1745 OSPF interactions
–  RFC 1997 Communities & Attributes
–  RFC 2439 route flap dampening
–  RFC 2796 route reflection
–  RFC 3065 BGP4 confederations
–  RFC 3392 Capability Advertisement
–  RFC 2918 Route Refresh Capability
–  RFC 1269 Managed Objects for BGP
–  RFC 1657 Managed Objects for BGP-4 
 using 

SMIv2

–  RFC 3682 Generalized TTL Security Mechanism 
 

for eBGP Session Protection

–  RFC 2385 BGP Session Protection via TCP MD5
–  draft-ietf-idr-restart Graceful Restart for BGP
– draft-ieft-idr-route-filter

OSPF

–  RFC 2178 OSPF
–  RFC 1583 OSPF v2
–  RFC 3101 OSPF NSSA
–  RFC 1745 OSPF Interactions
–  RFC 1765 OSPF Database Overflow
–  RFC 1850 OSPF v2 MIB and Traps
–  RFC 2328 OSPF v2
–  RFC 2370 OSPF Opaque LSA Option
–  RFC 3623 Graceful OSPF Restart

IS-IS

–  RFC 1195 Routing in TCP/IP and
 Dual 

Environments

–  RFC 2763 Dynamic Host Name Exchange
–  RFC 2966 Domain-wide Prefix Distribution
–  RFC 3567 IS-IS Cryptographic Authentication
 (MDS) 

RIP

–  RFC 1058 RIP v1
–  RFC 1723 RIP v2
–  RFC 1812 RIP Requirements

IP Multicast

–  RFC 1122 Host Extensions
–  RFC 1256 ICMP Router Discovery Protocol
–  RFC 1112 IGMP
–  RFC 2236 IGMP v2
–  RFC 2362 PIM-SM
–  RFC 3973 PIM-DM
– PIM-DM 

v1

– DVMRP 

v3-07

–  RFC 1075 DVMRP v2
–  RFC 2336 IGMP v2
–  RFC 3618 MSDP
–  RFC 2283 MBGP
–  RFC 2858 BGP-MP
–  RFC 3376 IGMP v3
–  RFC 3446 Anycast RP
–  RFC 4541 Considerations for IGMP 
 

and MLD Snooping

General Protocols

–  RFC 791 IP
–  RFC 792 ICMP
–  RFC 793 TCP
–  RFC 783 TFTP
–  RFC 826 ARP
–  RFC 768 UDP
–  RFC 894 IP over Ethernet
–  RFC 903 RARP
–  RFC 906 TFTP Bootstrap
–  RFC 1027 Proxy ARP
–  RFC 950 Subnets
–  RFC 951 BootP
–  RFC 1122 Host Requirements
–  RFC 1256 IRDP
–  RFC 1519 CIDR
–  RFC 1542 BootP Extensions
–  RFC 1812 General Routing
–  RFC 1541 and 1542 DHCP
–  RFC 2131 BootP/DHCP Helper
–  RFC 3768 VRRP
–  RFC 854 TELNET
–  RFC 1591 DNS (client)
–  RFC 2784 GRE
–  RFC 1191 Path MTU Discovery
–  RFC 896 Congestion Control
–  RFC 3635 Pause Control
–  RFC 1858 IP Fragment Filtering
–  RFC 1340 Assigned Numbers

Others

–  RFC 2578 SMIv2
–  RFC 2579 Textual Conventions for SMIv2
–  RFC 2665 Ethernet Interface MIB
–  RFC 1354 IP Forwarding MIB
–  RFC 1757 RMON Groups Partial 1, full for 2, 3, 9
–  RFC 2068 HTTP
–  RFC 1305 NTPv3 Specification, Implementation 
 and 

Analysis

–  RFC 2030 SNTP
–  RFC 2138 RADIUS
–  RFC 3176 sFlow
– Draft-ietf-tcpm-tcpsecure-00

IPv6 Core

–  RFC 2373 IPv6 Addressing architecture
–  RFC 1886 DNS Extensions to support IPv6
–  RFC 1887 IPV6 Unicast address allocation architecture
–  RFC 2374 IPv6 aggregatable global Unicast address format
–  RFC 2450 Proposed TLA and NLA Assignment Rules
–  RFC 2471 IPv6 testing address allocation 
–  RFC 2526 Reserved IPv6 subnet anycast address
–  RFC 2928 Initial IPv6 sub TLA ID assignments
–  RFC 2460 IPv6 Specification
–  RFC 2461 IPv6 Neighbor Discovery
–  RFC 2462 IPv6 Stateless Address Auto-configuration
–  RFC 4443 ICMPv6
–  RFC 3513 IPv6 Addressing Architecture
–  RFC 1981 IPv6 Path MTU Discovery
–  RFC 3587 IPv6 Global Unicast Address Format
–  RFC 2375 IPv6 Multicast Address Assignments
–  RFC 2464 Transmission of IPv6 over Ethernet Networks
–  RFC 2711 IPv6 Router Alert Option
–  RFC 3363 DNS support

IPv6 Routing

–  RFC 2080 RIPng for IPv6
–  RFC 2740 OSPFv3 for IPv6
–  IETF Draft_ietf_isis_IPv6 IS-IS for IPv6
–  RFC 2545 Use of MP-BGP-4 for IPv6

IPv6 Multicast

–  RFC 2362 PIM-SM
–  RFC 2710 Multicast Listener Discovery (MLD) for IPv6
–  RFC 3306 Unicast-Prefix-based IPv6 Multicast Addresses
–  RFC 3810 MLDv2
–  RFC 4602 PIM-SM (Partial Address)
–  draft-holbrook-idmr-igmpv3-ssm—IGMPv3 & MDLV2 
 for 

SSM

–  draft-ietf-ssm-arch SSM for IP

Summary of Contents for BIGIRON RX-32

Page 1: ...computing environments and Internet Exchanges and Internet Service Providers IXPs and ISPs where non blocking high density Ethernet switches are needed All four BigIron RX systems are designed for non...

Page 2: ...switch trunking t High availability design features redundant and hot pluggable hardware hitless Layer 2 software upgrades and graceful BGP and OSPF restart t Advanced non blocking Clos fabric featur...

Page 3: ...warding engine on each line module This memory can be pre populated with as many as 512 000 IPv4 and 64 000 IPv6 routes for wire speed routing performance t Policy based Routing PBR Support customizab...

Page 4: ...Manager is a web based graphical interface tool that empowers network operators to seamlessly control software and configuration updates t Command Line Interface CLI Industry standard configuration in...

Page 5: ...e common architecture that meets the demands of today s and tomorrow s Enterprise network needs with high performance resiliency security and scalability with low TCO Applications FOUNDRY ENTERPRISE I...

Page 6: ...ing as the technology of choice Ultra low latency and high density Ethernet switching are required for successful deployment The BigIron RX Series chassis are ideal for this environment They offer low...

Page 7: ...BGP Session Protection RFC 2385 BGP Session Protection via TCP MD5 draft ietf idr restart Graceful Restart for BGP draft ieft idr route filter OSPF RFC 2178 OSPF RFC 1583 OSPF v2 RFC 3101 OSPF NSSA RF...

Page 8: ...45 w x 57 71 h x 24 1 d 44 32w x 146 58h x 61 21d cm approx 478 lbs approx 217 kg BigIron RX 16 17 45 w x 24 47 h x 25 5 d 44 32w x 62 15h x 64 77d cm 236 lbs 107 kg BigIron RX 8 17 45 w x 12 21 h x...