2
For
A. D. A.
compliance, top of lower double stud should be
30.5“ (78 cm) from the floor.
Recommended Blocking:
Wood double stud blocking is necessary. Contact an architect and
building official to make sure the blocking is adequate and complies
with building codes (
Fig. b)
.
1. Slide changer into blocking area and mark mounting hole location
on blocking studs.
HINT:
This may require 2 additional people to help hold changer
in position while you are marking the locations.
2. Shim changer for a snug fit.
3. Align holes in changer with marked holes and secure using the
appropriate fasteners
(Fig. c)
.
NOTE:
It is installers responsibility to provide correct fastereners
for other substrates.
4. Ensure all six (6) fasteners are tight.
INSTALLATION - RECESSED
INSTALLATION - SURFACE-MOUNT
Recommended Blocking:
If the walls do not have studs on center, then additional blocking is necessary
(Fig. d)
.
Contact an architect or building contractor to make sure the blocking is adequate
and complies with building codes.
For
A. D. A.
compliance, measure up 62 3/4” (159 cm) from the floor and mark the
wall. This locates the position for the top left attachment hole.
NOTE:
- Changer MUST be mounted to studs
(Fig. e)
.
- This unit incorporates a finishing collar that seats behind the changer’s
outside flange. Center the collar as the unit is being tightened against
the wall
(Fig. f)
.
Fig. c
Recess
Mounting
Holes
Recess
Mounting
Holes
Recess
Mounting
Holes
22-1/2" (571 mm)
Rough-in
Double Stud
Double Stud
D
ou
bl
e
S
tu
d
D
ou
bl
e
S
tu
d
34-1/8"
(867 mm)
Rough-in
3-7/8"
(98.6 mm)
1"
(25.4 mm)
22-1/2"
(571 mm)
For A. D. A.
Compliance
30.5”
(78 cm)
TOP
VIEW
FRONT
VIEW
A. F. F
30-1/2”
(775 mm)
Fig. b
Fig. e
Surface-Mount
Holes
26"
(660 mm)
on center
16"
(406 mm)
on center
Top
For A. D. A.
Compliance
62 3/4”
(159 cm)
A. F. F
Fig. d
Fig. f
Collar
Unit
Wall