PV power 

4 mm²

6 mm²

10 mm²

~325 Wᵖ

≤ 18 m

≤ 27 m

≥ 27 m

~650 Wᵖ

≤ 11 m

≤ 16 m

≥ 16 m

~975 Wᵖ

≤ 9 m

≤ 13 m

≥ 13 m

Recommended cable length (there and back) for  

different nominal powers and cross-sections

Connection of an external power supply

IMPORTANT!

 Only use power supply units recom-

mended by the manufacturer. Non-compliance will 

invalidate the warranty and may damage the water 

heater.

External power supply units feature extended use of 

the photovoltaic boilers. For example, long periods 

of bad weather can be bridged by connected AC pow-

er supply units (model number: PSU-12, PSU-18). 

Furthermore, you have the option of converting sur-

plus energy from photovoltaically charged accumu-

lators into heat by the water heater. For detailed 

information, please refer to the description of the 

respective unit.

Operation

WARNING!

 This device may only be operated by 

a person (including children over the age of 8) with 

reduced physical or mental capabilities if they are 

supervised or have been instructed in the use of the 

appliance by a responsible person. Children must be 

supervised to prevent them from playing with the 

appliance under any circumstances. It is forbidden 

for children to clean or operate the water heater. 

Operation

 

Switch On:

 Press the   - button for three seconds.

 

Display:

 The present water temperature is shown 

on the display. 

•  POWER IN: Input power of the PV modules

•  VOLTAGE: Input voltage of the PV modules

•  EXT SUPPLY: Connection of an external supply

•  USED PV ENERGY: Total PV energy utilised

Menu Navigation:

 Press the 

 - button briefly. By 

pressing the button again, you jump to the next page 

in the menu. 

Settings:

 Press the   - button repeatedly. This all-

ows individual adjustments on the unit to be made. 

Please note: The adjustments are only active when 

an external energy supply is connected to the photo-

voltaic water heater. 

•  CHANGE MIN. TEMPERATURE: Select the  

desired minimum temperature by pressing the  

 - button. 

•  CHANGE SYSTEM MODE:  Select the desired 

mode by pressing the   - button. Mode 1 

(PV HOME) is set as the factory default.

Quick guide: System modes

Mode 1 (PV HOME)

For the direct connection of photovoltaic modules. 

Plus a fothermo power supply (can be purchased 

separately) if desired. 

Mode 2 to 6

For the connection of external energy sources such 

as a battery. A  fothermo battery cable is needed 

and can be purchased separately. More detailed 

information can be found in the respective product 

description.

Switch off:

 Press the   - button for three seconds. 

Further important notes

 

Leakage of water

The pressure relief valve can drip during the opera-

tion of the water heater due to the expansion of the 

water while heating. Ensure that the leaking water 

is directed to a collection container or a drain. The 

dripping of water does not indicate a defect. The 

side valve opening must not be closed under any 

circumstances. 

The installation of a drainpipe facilitates future 

maintenance and servicing operations, as the water 

can be drained from the water heater easily.

Summary of Contents for PVB-10

Page 1: ...hnical description Installation operation and maintenance instructions Warranty conditions EN DE Photovoltaischer Boiler PVB 10 30 80 Technische Beschreibung Montage Betriebs und Wartungsanleitung Gewährleistungsbedingungen use the power of sun ...

Page 2: ...2 ...

Page 3: ...nection to the water suppy 09 Electrical connection 10 Operation 12 Maintenance 13 Malfunction 13 Environmental protection 13 Warranty 14 DE Spezifikationen 16 System Modi 17 Montage 18 Anschluss 19 Weiterführende Informationen 20 Allgemeine Warnhinweise 20 Sicherheitshinweise 20 Weitere wichtige Hinweise 20 Technische Daten 21 Montage 21 Anschluss an die Wasserleitung 21 Elektrischer Anschluss 23...

Page 4: ...ted MPP tracker integrated reverse polarity protection digital display prepared for external reheating and battery connection boiler made of steel with enamel coating CE certification dimensions length width height cm 28 x 28 x 44 40 x 40 x 60 47 x 48 x 90 water connection G M G M G M combined check and pressure relief valve photvoltaic input recommended photovoltaic power Wᵖ 100 300 300 600 600 1...

Page 5: ...inimum temperature But only as long as the battery voltage does not drop below 12 4 V 12 V battery Approved LiFePO4 lead acid 4 This mode should be selected if there is an external energy management system e g solar charge controller with deep dischar ge protection that releases the power for the boiler External energy management 5 As soon as the connected battery reaches a voltage of 27 0 V the e...

Page 6: ... 10 litre boiler must be installed vertically on a wall that is at a 90 angle to the floor 1 2 3 4 5 photovoltaic water heater PVB 30 PVB 80 The 30 and 80 litre boiler must be installed vertically on a wall that is at a 90 angle to the floor on the back 2 3 1 ...

Page 7: ...ature water withdrawal and may differ from reality The greater the connec ted photovoltaic power the more the water can be heated on days with low solar radiation The water is heated with a maximum power of 550 W even if more photovoltaic power is available 8 3 1 2 5 6 4 7 1 hot water tank 2 water inlet 3 water outlet 4 shut off valve 5 combined check and pressure relief valve 6 pressure reducing ...

Page 8: ... with water before connecting it to the electrical supply Failuretocomplywiththeelectricalconnectioncon ditions affects the safety of the appliance whereby the water heater must not be operated IMPORTANT Observe the maximum permissible pressure see chapter Technical data Further important notes The appliance is under pressure During heating expansion water may drip from the pressure relief valve O...

Page 9: ...g A drilling hole template is enclosed with the product PVB 30 and PVB 80 The fixing elements e g 12mm stud bolts must be secured against being pulled out of the wall The securing elements must be designed for THREE TIMES the weight of the water heater filled with water Shims are to be placed under the screw heads of stud bolts A drilling hole template is printed on the product packaging Connectio...

Page 10: ...ROHIBITED The pressure relief valve can also be used to drain the water from the tank if desired In such case pro ceed as follows Disconnect the water heater from any live electrical wiring Disconnect the cold water inlet Open the hot water tap of the mixing tap or disconnect the hot water pipe return pipe of the water heater Lift the small lever of the pressure relief valve Table 1 No 5 and wait ...

Page 11: ...tly using the factory supplied MC4 plugs You may connect up to five modules in parallel Depending on the module this corresponds to an MPP output of approximately 1500 Wp Dimensioning of the required photovoltaic power The higher the number of hours of sunshine per day the smaller the required PV power The warmer the water taken from the pipeline the lower the required PV power Dimension the requi...

Page 12: ... voltage of the PV modules EXT SUPPLY Connection of an external supply USED PV ENERGY Total PV energy utilised Menu Navigation Press the button briefly By pressingthebuttonagain youjumptothenextpage in the menu Settings Press the button repeatedly This all ows individual adjustments on the unit to be made Please note The adjustments are only active when anexternalenergysupplyisconnectedtothephoto ...

Page 13: ...f just wiped off with a dry cotton cloth The regular cleaning and removal of the limescale is essential to ensure the safe operation of the appliance Whilst cleaning the anode of the enamelled water tank should also be checked These services are not part of the warranty scope and must be carried out by qualified persons The regulations for the inspection oftheanodeprotectionandrenewaloftheanode as...

Page 14: ...attempts to repair the appliance In the aforementioned cases the damage will be repaired against payment The guarantee does not apply to parts and components of the device that are worn out during its normal operation nor to partsthataredismantled tolightsandsignallamps etc to discoloration of external surfaces to chan ges in the shape dimensions and arrangement of parts and components that have b...

Page 15: ...15 EN ...

Page 16: ...r Integrierter Verpolungsschutz Digitales Display Vorbereitet für externe Nachheizung und Akku anschluss Boiler aus Stahl mit Emaillebeschichtung CE zertifiziert Maße Länge Breite Höhe cm 28 x 28 x 44 40 x 40 x 60 47 x 48 x 90 Wasseranschluss G M G M G M Kombiniertes Rückschlag und Überdruckventil Photovoltaikanschluss Empfohlene Photovoltaikleistung Wᵖ 100 300 300 600 600 1200 Max anschließbare P...

Page 17: ...t temperatur unterschritten wird Jedoch nur solange die Batteriespannung 12 4 V nicht unterschreitet 12 V Akku Zugelassen LiFePO4 Bleiakku 4 Dieser Modus sollte gewählt werden wenn ein externes Energiemanagement z B Solarladeregler mit Tiefentladeschutz existiert welches den Strom für den Boiler freigit Externes Energie Management 5 Sobald der angeschlossene Akku eine Spannung von 27 0 V erreicht ...

Page 18: ...lers muss vertikal an einer Wand erfolgen die sich in einem 90 Winkel zum Boden befindet 1 2 3 4 5 Photovoltaischer Boiler PVB 30 PVB 80 auf der Rückseite 2 3 1 Die Installation des 30 und 80 liter Boilers muss vertikal an einer Wand erfolgen die sich in einem 90 Winkel zum Boden befindet ...

Page 19: ... Wasser an Tagen mit geringer Sonneneinstrahlung erwärmt werden Das Wasser wird mit einer maximalen Leis tung von 550 W erwärmt auch wenn mehr photo voltaische Leistung zur Verfügung steht 8 3 1 2 5 6 4 7 1 Warmwasserspeicher 2 Wasserzufluss 3 Wasserabfluss 4 Sperrhahn 5 Kombiniertes Rück sclag und Überdruck ventil 6 Druckminderventil 7 Kaltwasser 8 Warmwasser nicht im Lieferumfang enthalten Ansch...

Page 20: ...e Personen dürfen den WarmwasserspeicherentsprechenddenVorgabenin diesem Handbuch und der einschlägigen örtlichen Vorschriften installieren und an die Wasserleitung anschließen Die vom Hersteller bereitgestellten oder empfohlenen Schutzeinrichtungen sowie alle anderen Baugruppen sind UNBEDINGT einzubauen WICHTIG VorAnschlussandieelektrischeEnergie versorgung ist der Warmwasserspeicher unbedingt mi...

Page 21: ... der Schutzgrad gegen Wasserspritzer DerAufstellungsortmussmitdenAnforderungender elektrischen Installation übereinstimmen Bei der Montage ist ausreichend Abstand zu benachbarten Wänden und genügend Abstand unter dem Gerät für Wasser und Photovoltaikanschlüsse vorzusehen PVB 10 Die Aufhängeleiste siehe Abbildung 1 wird mit Hilfe von zwei mitgelieferten Dübeln und Schrauben an die Wand sicher befes...

Page 22: ...sser etwa 30 Sekunden laufen lassen Warmwasserhahn der Mischbatterie schließen Den kleinen Hebel des Überdruckventils Tabel le 1 Nr 5 heben 30 60 Sekunden abwarten bis aus der seitlichen Öffnung des Ventils ein starker Wasserstrahl fließt Ventilheben lösen WARNUNG Fließt kein Wasser aus der Ventilöff nung oder fließt nur ein dünner Strahl dann deutet dies auf eine Fehlfunktion hin Möglicherweise l...

Page 23: ...romversorgungsanlagevollständiggetrennt wenn alle Versorgungsstecker getrennt sind Anschluss von Photovoltaikmodulen WICHTIG Die Montage und die elektrische Par allelschaltung von PV Modulen darf nur von einer fachkundigen Person durchgeführt werden und muss eine Gefährdung Dritter ausschließen Bei der Montage der Photovoltaikmodule sind die vor Ort geltenden Regeln und Gesetze einzuhalten WICHTIG...

Page 24: ...ter Externe Energieversorgungsgeräte dienen zur er weiterten Nutzung der photovoltaischen Boiler Beispielsweise können lange Schlechtwetterphasen durch angeschlossene AC Netzgeräte überbrückt werden Modellnummer PSU 12 PSU 18 Des Weiteren besteht die Möglichkeit überschüssige Energie aus photovoltaisch geladenen Akkumula toren in Wärme im Boiler umwandeln Detaillierte InformationenentnehmenSiebitt...

Page 25: ...asser speicher kann die Gefahr von Legionellenbildung im System nahezu ausgeschlossen werden Um dennoch Vorsichtsmaßnahmen zu treffen werden folgende Maßnahmen empfohlen Zufuhr von Frischwasser bzw regelmäßige Wasserentnahme Erhitzung des Wassers in regelmäßigen Abstän den auf mindestens 60 C Nach Nichtbenutzung des Gerätes von mehr als einem Monat wird ein Wassertausch empfohlen Wartung und Insta...

Page 26: ...mweltschutz Dieses Gerät ist entsprechend der Richtlinie für die Elektro und Elektronik Altgeräte WEEE gekenn zeichnet Indem Sie dafür sorgen dass das Gerät am Ende seiner Lebensdauer bei einem geeigneten Entsorgungszentrum abgegeben wird tragen Sie zum Umweltschutz und zur Vermeidung von ne gativen Einwirkungen auf die Umwelt und auf die menschliche Gesundheit bei Das Symbol auf dem Warmwasserspe...

Page 27: ... der Zeit seiner Reparatur und Wartung werden von der Gewährleistung des Geräts nicht gedeckt DIEEINHALTUNGDERANGEGEBENENANFORDERUN GENIMHANDBUCHSINDVORAUSSETZUNGFÜRDEN SICHEREN BETRIEB DES GEKAUFTEN PRODUKTS UNDZÄHLTZUDENGEWÄHRLEISTUNGSBEDINGUN GEN JEGLICHE VOM BENUTZER ODER VON DEN VON IHM BEVOLLMÄCHTIGTEN PERSONEN VORGE NOMMENE ÄNDERUNGEN UND UMBAUTEN AN DER KONSTRUKTION DES PRODUKTS SIND STREN...

Page 28: ......

Reviews: