ISSUE DATE 10-09-03 REV. DATE 5-24-05 REV. LEVEL: 03 ECN OIPM P/N 3420265 PG 14 OF 16
MAINTENANCE
LIMITED WARRANTY
FOSTORIA INDUSTRIES, INC. - Fostoria, Ohio 44830-0986 - (419) 435-9201
The warranty herein set forth is in lieu of all other warranties expressed or implied.
Fostoria Industries, Inc. of Fostoria, Ohio 44830, warrants its products to the owner against defects in material and workmanship for a twelve (12) month period
under normal use and service following date of manufacture or installation when proof of such is provided to seller.
This Warranty requires that the owner, or his agent, install the equipment in accordance with the National Electrical Code, any other applicable heating or
electrical codes and the manufacturer’s installation instructions. It further requires that he perform reasonable and necessary maintenance on the unit. The
company is not liable for abuse or misuse of product as may be finally determined by the company.
The obligation of Fostoria Industries, Inc. under the terms of this warranty, shall be to supply a new part, repair of defective part, or a refund, at the company’s
option with no cost to owner for the new or repaired part. Such parts are to be returned to the factory, or such other location as the company may designate.
This warranty does not obligate Fostoria Industries, Inc. to bear the cost of labor in replacing any assembly, unit or component part thereof, nor does the
company assume any liability for secondary charges, expenses for installing or removal, or any other consequential losses. The company’s maximum liability
shall not in any case exceed the list price for the product claimed to be defective.
The warranty shall not apply to any product or parts of products that have been repaired or altered outside of Seller’s factory in any manner. Warranty is void on
products that have been determined to have been subjected to misuse, negligence or accident or which have been used in a manner contrary to Seller’s
instructions.
Pre-Season Maintenance and Annual Inspection
To ensure your safety and for years of trouble-free operation of the heating system, annual service and
inspections must be done by a qualified contractor.
To obtain maximum performance from your heater(s) each year, we recommend the following be
performed at the start of the heating season:
1. Clean reflector surface with a damp cloth.
2. Make sure heater is secure on all hanging points.
3.
Maintain the Clearance to Combustibles.
Immediately remove objects in violation of the
clearance to combustibles.
If additional service to the heater is required, contact the factory or your local representative
.
1. Add more heaters.
2. Decrease mounting height or distance.
1. Heater too small for application.
2. Heater mounted too high or too far.
SYMPTOM
POSSIBLE CAUSE(S)
CORRECTIVE ACTION
Element does not
energize.
1. Defective element.
2. Improper connection.
3. Pigtail loose from socket connection.
1. Replace element.
2. Check connection to power source.
3. Rewind or re-insert pigtail into socket.
Not enough heat.
Too much heat.
1. Heater too large for application.
2. Heater mounted too low or too close.
1. Replace with smaller heater.
2. Increase mounting height or distance.