background image

Product Specifications

Cable and Wiring Information

Product Cleaning Instructions

Cabinet Dimensions

Amplifier Power

Amplifier Distortion

Amplifier Signal to Noise Ratio

Net Weight

6.5 Kg

16 Kg

14.3 Pounds

35.2 Pounds

Gross Weight Per pair (includes all packing material)

Frequency Response

20Hz - 30kHz Not Weighted

Low Frequency : 35 Watts

High Frequency : 35 Watts

Amplifier Slew Rate

15V/  sec

>84dB

<0.001

%

THD @ 25Watts / 8Ohm 20Hz-20kHz

Product improvement may warrant a change of specifications, newer materials or cosmetics, Changes in

specifications and features may be made without notice or obligations.

Use high-quality, shielded cables to connect your mixing console, workstation or other source to your

monitors.  Foil-shielded cables, such as Belden 8451, 8761, or 9501 should do quite well. Other high

quality cables are available and those that incor porate better shielding will yield an overall higher noise

rejection, lowering your systems susceptibility to external interference.  Another important tip to keep in

mind when wiring your system is to route all line level cables away from the AC and other power

sources, this will reduce the probability of having AC hum emanating from your studio monitors.

181mm (W) × 280mm (H) ×260mm (D) includes heatsink

230mm (D) cabinet only - no heatsink

7 1/8" (W) × 11" (H) × 10 1/4" (D) includes heatsink

9" (D) cabinet only - no heatsink

Free-Field Frequency Response : ±2dB 50Hz to 20KHz

Low Frequency Cutoff : 40Hz (-10dB)

High Frequency Cutoff : 22kHz (-10dB)

HOT (+)

XLR

PIN 2
PIN 3
PIN 1

TIP

TIP

RING

COLD (-)

SHIELD (

GROUND

)

Prior to cleaning the PM0.5 MK

monitor the power must be disconnected from the PM0.5 MK

monitor.

Once the power has been terminated, cleaning can be accomplished using a damp (not wet) cleaning

rag. A light common household cleaner can also be used, but care must be taken not to use harsh

cleaning fluids. Regular dusting or cleaning with a damp rag will keep your product looking new for years.

Power Requirements

Power consumption

US : 120VAC~60Hz

EUR/UK : 230VAC~50/60Hz

US : 35 Watts

EUR/UK : 40 Watts

p-6

RCA

TRS

SHIELD

SHIELD

Summary of Contents for PM-0.5 MKII

Page 1: ...ntroduction Unpacking Setup Instructions continued Product Cleaning Instructions Setup Instructions Back Panel Overview Safety Instructions Cable and Wiring Information Product Specifications Declaration of EC Directive p 3 p 5 p 6 p 4 p 5 p 2 p 6 p 6 p 7 p 1 PM 0 5 MK ...

Page 2: ...8 19 20 21 22 23 NO USER SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL SHOCK DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE manufacturer 10 11 Power Sources The appliance should be connected to a power supply only of the type described in the operating instructions or as marked on the appliance Grounding or Polarization The precautions that should be taken so that the g...

Page 3: ... this manual so that you may take full advantage of all the benefits of the Fostex PM0 5 MKⅡ Professional Studio Monitor manufacturing techniques Prior to unpacking your Fostex PM0 5 MKⅡ Studio Monitor carefully inspect the packing material for excessive damage Once it has been determined that the packing material has not been compromised carefully unpack the PM0 5 MKⅡ Studio Monitor and inspect i...

Page 4: ...the listening possible it may be necessary to tilt aim the monitor at the listeners ears Monitoring Height the acoustic center aimed at seated ear height Monitoring Angle 60 Degrees easiest way to determine this is to place the speakers in such a way that the position should equal 60 degrees The distance between the left and right monitor is equal to the monitoring distance listening position see ...

Page 5: ...ial and make any final adjustments as far as placement or level to get the optimum performance in your monitoring environment PM0 5 MKⅡ studio monitors to the mixing console or digital workstation Connection to the PM0 5 MKⅡ can be POWER AC IN MADE IN CHINA CAN CSA STD E60065 CERTIFIED TO UL STD 6500 CONFORMS TO 3024002 C US CM LISTED CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN AVIS WARNING RISQUD ...

Page 6: ...wering your systems susceptibility to external interference Another important tip to keep in mind when wiring your system is to route all line level cables away from the AC and other power sources this will reduce the probability of having AC humemanating from your studio monitors 181mm W 280mm H 260mm D includes heatsink 230mm D cabinet only no heatsink 7 1 8 W 11 H 10 1 4 D includes heatsink 9 D...

Page 7: ...87 0300 FAX 33 1 4987 0324 FRANCE Cedex France NAME Noretron Oy Audio ADD P O Box 22 FIN 02631 Espoo Finland TEL 358 9 5259330 FAX 358 9 52593352 FINLAND NAME Mega Audio GmbH ADD Stromberger Str 32 D 55411 Bingen Germany TEL 49 6721 94330 FAX 49 6721 32046 GERMANY NAME Bon Studio S A ADD 6 Zaimi Street Exarchia 106 83 Athens Greece TEL 30 210 3809 605 606 607 608 FAX 30 210 3845 755 210 3827 868 G...

Reviews: