Fostex PD204 Owner'S Manual Supplement Download Page 3

3

Model PD204 Owner’s manual <Version1.01 supplement>

Key operation for the disk copy function

With the new version, the key operation for executing disk copy is changed. For details about the
disk copy function, see page 107 of the operation manual.

Key operation with the earlier version (see page 109 of the operation manual.)

After the display shows the confirmation message as below, press the [ENTER/YES] key.

Key operation with the new version

After the display shows the confirmation message as below, press the [ENTER/YES] key while
pulling the [REC] key to the right
.

Threshold level setting

Ratio setting

You can select "-6dBFS" or "-12dBFS". (The default is "-6dBFS".)

Limiter level detection mode setting

You can select "1:3" or "1:5". (The default is "1:5".)

You can select "Peak" or "RMS" (The default is "Peak".)

Peak

RMS

<Note>: 

The RMS mode is available when the FS is 48 kHz or less. When the FS is higher

than 48 kHz, the limiter works in the peak mode.

The level detector detects the peak level of a signal.
The limiter is activated when the peak level of the signal exceeds the threshold level.
If you select "Peak" while you set the threshold level to "-12dBFS", you may feel the limiter
works too sensitively compared to a conventional analog limiter. Therefore when you select
"Peak", it is recommended that you set the threshold level to "-6dBFS".

The level detector detects the RMS level of a signal.
The limiter is activated when the RMS level of the signal exceeds the threshold level. In this
mode, the limiter works similar to a conventional analog limiter.