2

Keypad Security Settings

This function avoids unauthorised controller access. 
Press & release ‘

i

’ then use       to select ‘LOC’. Press and hold ‘

i

’ to change from ‘YES’ to ‘NO’. Leave for 10 

seconds or briefly press

       to resume.

Set Point

To amend the set point press and hold the ‘

i

’ button for half a second. Then while keeping the ‘

i

’ button pressed use 

the      and      buttons to set the desired value.
When the ‘

i

’ button is released the new value will be stored automatically.

Defrost

Models are fitted with a fully automatic defrost system to ensure that the evaporator coil or cooling plate remains 

free from ice in normal use. ‘Melt water’ is automatically evaporated using the heat from the refrigeration system.

Cleaning and Maintenance

Important: Before cleaning, the unit should be put into standby and then the power supply should be 

turned off at the mains. Please do not plug or unplug the unit with wet hands. Only when cleaning has 

been completed and the unit is dry should the cabinet be turned back on at the mains. 

Suitable P.P.E (Personnel Protective Equipment) should be worn at all times.

Regular Maintenance:

As and when required remove all product from the unit. Clean exterior and interior surfaces with mild 

liquid detergent, following the directions on the pack at all times. Rinse surfaces with a damp cloth 

containing clean water. Never use wire wool, scouring pads/powders or high alkaline cleaning agents i.e 

bleaches, acids and chlorines as these may cause damage. 

>

 

Condenser Cleaning:

This should take place on a regular basis or as and when required (4 to 6 weeks) by a competent/trained 

personnel.

Use a soft brush or vacuum cleaner to remove dirt/dust. If there are any stubborn grease deposits left on 

or through the condenser, call your supplier to carry out a full service (this is normally chargeable). Failure 

to maintain the condenser may invalidate the warranty of the condensing unit and cause premature 

failure of the motor/compressor. 

Do not use a wire brush to clean the condenser. Vacuum or brush the air filter (where fitted).

All gaskets should be inspected on a regular basis and replaced if damaged. To clean, wipe with a 

warm damp soapy cloth followed by a clean damp cloth. Finally thoroughly dry. 

GB

Troubleshooting

During normal operation the display will show either the temperature or one of the following alarm or warning 

indicators:

Defrost In Progress

Room High Temperature Alarm

Controller In Standby

Room Low Temperature Alarm

Keypad Locked

Probe T1 Failure

Generic Alarm

(Some icons or switches are only visible during adjustment, when activated by parameters or through operation/

manual selection).

Summary of Contents for HR80MF

Page 1: ... 216 8800 Fax 44 0 843 216 4700 Email support foster uk com www fosterrefrigerator co uk A Division of ITW Ltd Foster Refrigerator Oldmedow Road King s Lynn Norfolk PE30 4JU United Kingdom ISO 9001 ISO 14001 Original Operation Instructions Milk Fridge HR80MF Model BIT25 Controller LCD5S Display 00 570130 November 2014 Issue 1 English ...

Page 2: ...d on a firm level surface away from both hot and cold air sources as this will affect its performance Please ensure when installing this model into kitchen units cut outs are added to the rear and base Also when installed a minimum clearance of 25mm to the front and sides of the model inside the unit is available These are all required for effective ventilation and operation Connect the unit to a ...

Page 3: ...detergent following the directions on the pack at all times Rinse surfaces with a damp cloth containing clean water Never use wire wool scouring pads powders or high alkaline cleaning agents i e bleaches acids and chlorines as these may cause damage Condenser Cleaning This should take place on a regular basis or as and when required 4 to 6 weeks by a competent trained personnel Use a soft brush or...

Page 4: ...ctly cold or warm air sources are not affecting the performance e The condenser is not blocked or dirty f The products are placed in the unit correctly g Defrost is not in progress or required If the reason for the malfunction cannot be identified disconnect the electrical supply to the unit and contact your supplier When requesting a service call please quote the model and serial number which can...

Page 5: ...4 Page Left Blank Intentionally GB ...

Page 6: ...5 Page Left Blank Intentionally GB ...

Page 7: ...6 Page Left Blank Intentionally GB ...

Page 8: ...nas eu PL Spelnia wymogi następujących Dyrektyw Europejskich S ä normriktig och utformad enligt fölande Europeiska direktiv GB and have been designed realised and controlled according to the following regulations D das Gerät ist folgenden Normen gemäß entworfen angfertigt und geprüft worden DK er blevet projekteret realiseret og kontrolleret i følge neden for beskrevne normer E y estuvo proyectado...

Reviews: