2
Keypad Security Settings
This function avoids unauthorised controller access.
Press & release ‘
i
’ then use to select ‘LOC’. Press and hold ‘
i
’ to change from ‘YES’ to ‘NO’. Leave for 10
seconds or briefly press
to resume.
Set Point
To amend the set point press and hold the ‘
i
’ button for half a second. Then while keeping the ‘
i
’ button pressed use
the and buttons to set the desired value.
When the ‘
i
’ button is released the new value will be stored automatically.
Defrost
Models are fitted with a fully automatic defrost system to ensure that the evaporator coil or cooling plate remains
free from ice in normal use. ‘Melt water’ is automatically evaporated using the heat from the refrigeration system.
Cleaning and Maintenance
Important: Before cleaning, the unit should be put into standby and then the power supply should be
turned off at the mains. Please do not plug or unplug the unit with wet hands. Only when cleaning has
been completed and the unit is dry should the cabinet be turned back on at the mains.
Suitable P.P.E (Personnel Protective Equipment) should be worn at all times.
Regular Maintenance:
>
As and when required remove all product from the unit. Clean exterior and interior surfaces with mild
liquid detergent, following the directions on the pack at all times. Rinse surfaces with a damp cloth
containing clean water. Never use wire wool, scouring pads/powders or high alkaline cleaning agents i.e
bleaches, acids and chlorines as these may cause damage.
>
Condenser Cleaning:
This should take place on a regular basis or as and when required (4 to 6 weeks) by a competent/trained
personnel.
Use a soft brush or vacuum cleaner to remove dirt/dust. If there are any stubborn grease deposits left on
or through the condenser, call your supplier to carry out a full service (this is normally chargeable). Failure
to maintain the condenser may invalidate the warranty of the condensing unit and cause premature
failure of the motor/compressor.
Do not use a wire brush to clean the condenser. Vacuum or brush the air filter (where fitted).
>
All gaskets should be inspected on a regular basis and replaced if damaged. To clean, wipe with a
warm damp soapy cloth followed by a clean damp cloth. Finally thoroughly dry.
GB
Troubleshooting
During normal operation the display will show either the temperature or one of the following alarm or warning
indicators:
Defrost In Progress
Room High Temperature Alarm
Controller In Standby
Room Low Temperature Alarm
Keypad Locked
Probe T1 Failure
Generic Alarm
(Some icons or switches are only visible during adjustment, when activated by parameters or through operation/
manual selection).