Foster Display Case Parameter Settings Service Service Manual Download Page 7

 

 

Foster Display Case Parameter Settings 

Model 

 

 

NRC100 

Default 

C1.0-15/08

 

FPREM 
125HG 

FPREM 
195HG

 

FPRO 
90HG

 

FPRO 
130HG

 

FPRO 
195HG

 

MINI 

FM90 

130HG 

MINI 

FM120 
130HG

 

MINI 

FM90 

150HG 

MINI 

FM120 
150HG

 

Slim 

FS70 

HW

 

Slim 

FS90 

HW

 

Slim 

FS120 

HW

 

User Menu 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Temperature Set Point 1 

 

(ST1) 

 

 

 

 

 

 

 

 

 

 

 

 

 

Set Point Value 

ºC 

St1 

-1 

-1 

-1 

-1 

-1 

-1 

-1 

-1 

-1 

-1 

+2 

+1 

+1 

Differential 

ºC 

diF1 

Defrost Interval 

Dlt1 

Maximum Defrost Duration 

min 

dEt1 

35 

35 

35 

35 

35 

35 

35 

35 

35 

35 

35 

35 

35 

Defrost End Temperature 

ºC 

dSt1 

11 

11 

11 

11 

11 

11 

11 

11 

11 

11 

11 

11 

11 

Drain Down Time 

min 

Dt1 

Temperature Set Point 2 (if in use) 

 

(ST2) 

 

 

 

 

 

 

 

 

 

 

 

 

 

Set Point Value 2 

ºC 

St2 

-20 

 

 

 

 

 

 

 

 

 

 

 

 

Differential 2  

ºC 

diF2 

 

 

 

 

 

 

 

 

 

 

 

 

Defrost Interval 2 

dit2 

 

 

 

 

 

 

 

 

 

 

 

 

Maximum Defrost Duration 2 

min 

dEt2 

45 

 

 

 

 

 

 

 

 

 

 

 

 

Defrost End Temperature 2 

ºC 

dSt2 

11 

 

 

 

 

 

 

 

 

 

 

 

 

Drain Down Time 2 

min 

dt2 

 

 

 

 

 

 

 

 

 

 

 

 

Service Menu 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Settings Folder 

 

(SEt)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Parameter List 

 

SetC 

Keyboard Lock 

 

UlocC 

Setpoint Value 

ºC 

St1 

-1 

-1 

-1 

-1 

-1 

-1 

-1 

-1 

-1 

-1 

+1 

+1 

+1 

Lower Set Limit 

ºC 

SL1 

-2 

-2 

-2 

-2 

-2 

-2 

-2 

-2 

-2 

-2 

-2 

-2 

-2 

Upper Set Limit 

ºC 

SH1 

10 

10 

10 

10 

10 

10 

10 

10 

10 

10 

10 

10 

10 

Compressor Mode 

 

C1 

Setpoint Value 2 

ºC 

St2 

-20 

-20 

-20 

-20 

-20 

-20 

-20 

-20 

-20 

-20 

-20 

-20 

-20 

Lower Set Limit 2 

ºC 

SL2 

-30 

-30 

-30 

-30 

-30 

-30 

-30 

-30 

-30 

-30 

-30 

-30 

-30 

Upper Set Limit 2 

ºC 

SH2 

10 

10 

10 

10 

10 

10 

10 

10 

10 

10 

10 

10 

10 

Compressor Mode 2 

 

C2 

Defrost synchronization 

 

dSnC 

Probe Folder 

 

(SEn) 

 

 

 

 

 

 

 

 

 

 

 

 

 

Amount of Probes 

pcs 

SC 

Local Display 

 

dlSP 

Resolution 

 

dECP 

Filter Factor 

 

FC 

Display Temperature Offset 

 

oFFS 

Condenser Overheat Probe 1 

 

C1Pd 

Condenser Overheat Probe 2 

 

C2PD 

Compressor Folder 

 

(CP) 

 

 

 

 

 

 

 

 

 

 

 

 

 

Defrost Mode 

 

Min. Working Time 

min 

L on 

Max. Working Time 

min 

H on 

60 

60 

60 

45 

45 

45 

60 

60 

60 

60 

60 

60 

60 

Compressor off-time 

min 

oFFt 

Min. Down Time 

min 

CoFF 

Summary of Contents for Display Case Parameter Settings Service

Page 1: ...Display Case Service Manual Service Manual ISO 14001 ISO 9001...

Page 2: ...store and dispose of it in such a way as to prevent its escape into the environment harm to human health and to ensure the compliance with the environmental law Guidance is available from the Environm...

Page 3: ...ised Service Company Safety switch probe failure Call your Foster Authorised Service Company Safety switch is ON and cabinet lights are OFF alarm signal Indicates the condenser may need cleaning Switc...

Page 4: ...ours the second compressor has been running Press FNC to return to the main display User Menu Press and hold FNC for 5 seconds to enter the user menu use the UP or DOWN keys to scroll through and pres...

Page 5: ...nd control settings SH2 Upper Set Limit Maximum temperature set point for the second control settings C2 Compressor Mode 1 One compressor 1 Two compressors 3 Compressor Cycling If more than one compre...

Page 6: ...ailure 2dlF Compressor Difference Not used Condenser Overheat Folder OH AL Alarm Temperature Temperature at which the condenser alarm will be activated Alt Alarm Temperature Delay Time in minutes that...

Page 7: ...0 0 Setpoint Value C St1 1 1 1 1 1 1 1 1 1 1 1 1 1 Lower Set Limit C SL1 2 2 2 2 2 2 2 2 2 2 2 2 2 Upper Set Limit C SH1 10 10 10 10 10 10 10 10 10 10 10 10 10 Compressor Mode C1 1 2 2 1 1 2 1 1 1 1...

Page 8: ...195 18 18 2934 14 8 1800 20A 16A 63 2 59 PRO 90 18 1688 8 3 900 20A 13A 35 8 59 PRO 130 21 2058 9 9 910 20A 13A 43 9 59 PRO 195 14 14 2954 14 8 1360 20A 16A 63 7 59 SLIM 70 10 1248 6 4 460 20A 13A 25...