The cabinet has fixed positions for the shelving incorporated in the side air ducts.  

 

Door Open Alarm  

The  door  alarm  will  sound  if  the  door  is  left  open  for  more  than  5  minutes  when  the 

programme is running.  
The display will continue to display the alarm message until cancelled by shutting the door.  

If  the  alarm  cannot  be  cancelled  by  doing  this  call  your  Foster  Authorised  Service 
Company. 

 

High Temperature Alarm 

If  the  cabinet  temperature  remains  above  10°c  for  more  than  90  minutes  whilst  in  the 

storage mode the alarm will  
 

Air Probe Alarm 

 

In the event of the probe failing the alarm will sound and the display will show probe fault.  
Contact your Foster Authorised Service Company.  

 
Power Failure 

 

If  the  power  fails  for  up  to  five  minutes  the  unit  will  re-start  on  the  resumption  of  the 

power supply without affecting the selected cycle.  
If the power is off for longer than five minutes the controller will enter the hold mode.  

It  is  at  the  user’s  discretion  whether  the  stock  is  kept  or  disposed  of  depending  on  the 
length of the time the cabinet had no power

 

Important: Before cleaning the power supply should be turned off at the mains.  

Cared for correctly, stainless steel has the ability to resist corrosion and pitting for many 

years.  
The following weekly cleaning regime is recommended: 

a.

 

Exterior: use a proprietary stainless steel cleaner following the manufacturer’s 

instructions. 

b.

 

Interior: Wash with soapy water, rinse with clean water and dry thoroughly. 

 
WARNING: 

High alkaline cleaning agent or those containing bleaches, acids and chlorines are very 

harmful to stainless steel. Corrosion and pitting may result from their accidental or 
deliberate application. If any of these liquids should come into contact with the unit during 

general cleaning, wipe down the affected area with clean water and rub dry. 
Never use wire wool or scouring powders on stainless steel or aluminium surfaces. 

After cleaning allow the unit to reach its normal operating temperature before reloading 

with product. During usage all spills should be wiped clean immediately. 

 

Door Gaskets 

These should be inspected on a regular basis and replaced if damaged. To clean, wipe with 

a warm damp soapy cloth followed by a clean damp cloth and finally thoroughly dry before 

shutting the door. 

 

 
 

 
 

 

Summary of Contents for CT75

Page 1: ...216 8800 Fax 44 0 843 216 4700 Email support foster uk com www fosterrefrigerator co uk A Division of ITW Ltd Foster Refrigerator Oldmedow Road King s Lynn Norfolk PE30 4JU United Kingdom ISO 9001 ISO 14001 Original Operation Instructions Controlled Thaw CT75 Surf navigation Click Wheel Controller 00 570084 August 2014 Issue 2 English ...

Page 2: ...astors tilt the unit forwards remove the pallet and fit the castors in the mounting holes Ensure that all are tightened firmly into position Ensure during installation the unit is level if not the door may not close correctly Adjust castors by inserting spacers supplied separately under the appropriate castor and the base of the unit until level When mains electrical power is first applied to the ...

Page 3: ...RAM 2 PROGRAM3 5 30 PROGRAM 1 PHASE 1 PHASE 2 HOLD 59 59 PROGRAM 1 PHASE 2 HOLD 2 ºC PROGRAM 1 HOLD 5 30 PROGRAM 1 PHASE 1 PHASE 2 HOLD 10 C 2 Secs TURN TO SELECT PRESS TO START STORAGE PROGRAM 1 PROGRAM 2 PROGRAM 3 7 00 PROGRAM 2 PHASE 1 PHASE 2 HOLD 59 59 PROGRAM 2 PHASE 2 HOLD 2 ºC PROGRAM 2 HOLD 7 00 PROGRAM 2 PHASE 1 PHASE 2 HOLD 10 C 2 Secs TURN TO SELECT PRESS TO START STORAGE PROGRAM 1 PRO...

Page 4: ... the time the cabinet had no power Important Before cleaning the power supply should be turned off at the mains Cared for correctly stainless steel has the ability to resist corrosion and pitting for many years The following weekly cleaning regime is recommended a Exterior use a proprietary stainless steel cleaner following the manufacturer s instructions b Interior Wash with soapy water rinse wit...

Page 5: ...are any stubborn grease deposits etc left on or through the condenser call your Foster Authorised Service Company to carry out a full service Once the condenser has been cleaned switch the unit on Failure to carry out this action may invalidate the warranty of the condensing unit Airflow Do not obstruct the airflow throughout the cabinet interior Air inlet and outlet duct should not be obstructed ...

Page 6: ...GB 5 Page Left Blank Intentionally ...

Page 7: ...GB 6 Page Left Blank Intentionally ...

Page 8: ...inas eu PL Spelnia wymogi następujących Dyrektyw Europejskich S ä normriktig och utformad enligt fölande Europeiska direktiv GB and have been designed realised and controlled according to the following regulations D das Gerät ist folgenden Normen gemäß entworfen angfertigt und geprüft worden DK er blevet projekteret realiseret og kontrolleret i følge neden for beskrevne normer E y estuvo proyectad...

Reviews: