22
Installation procedure
• Worktop must be placed absolutely horizontal.
• Suitably protect the edges of the cut aperture.
• Connect the cooking hob to the mains power supply (see instructions for the
connection of the cooking hob to mains power supply).
• Insert the hob into the cut aperture.
• Press the hob firmly towards the worktop from above.
CONNECTION TO THE POWER SUPPLY
• Connections may be carried out by a qualified technician only. The earthing
protection must comply with the standing regulations.
• Connection terminals are revealed when the connection box cover is removed.
• Prior any attempted connection check that the voltage indicated on the rating
plate is in line with your home power supply.
• The rating plate is located underneath the appliance.
• The appliance is manufactured for use with the power supply voltage
230-240 V ~.
• The electric wiring should be equipped with a circuit breaker able to isolate the
appliance from the mains in all points, with the distance between terminals of at
least 3 mm in open position. This may be done by means of fuses, safety
switches, etc.
• The connection should be selected in accordance with the declared charge
capacity of the mains and the fuse power.
• Such appliances are allowed to be mounted on one side next to a high kitchen
cabinet, the height of which may exceed that of the appliance. On the opposite
side however, only a kitchen cabinet of equal height as the appliance is allowed.
• Upon the completion of installation, live wires and isolated cables must be
adequately protected against accidental touching.
Basic adjustment of
sensors to the ambience
Upon each connection to the power supply the sensors of the appliance are
automatically adjusted to the environment to ensure their proper function. All
displays turn on and are fully illuminated for a few seconds.
During the adjustment procedure the sensors must be free of any objects,
otherwise the adjustment procedure will be interrupted until such objects are
removed from the sensor surface. During this period the regulation of the
cooktop is impossible.
ATTENTION !
Before attempting any repairs on the appliance, disconnect the power supply. In
accordance with the mains voltage the appliance should be connected in line
with the attached diagram.
The earthing wire (PE) must be connected to the terminal marked with the
earthing symbol .
The connection cable must lead through the relief safety device, protecting it
from accidental pulling out. Upon the completion of installation switch all the
hotplates on for about 3 minutes to check the proper functioning.
Installation diagram
Connection must be carried out by means of harmonized cables as H05V2V2-F
(90°C), or with equal or better features.