26
ENGLISH
installation
4-Wire Cable from Home Power
Supply
IMPORTANT:
Use the 4-wire cable from
home power supply in the U.S.A. where
local codes do not allow grounding through
neutral, New Branch circuit installations
(1996 NEC), mobile homes and recreational
vehicles, new construction, and in Canada.
3-Wire Cable from Home Power
Supply - U.S.A. Only
IMPORTANT:
Use the 3-wire cable from
home power supply where local codes
permit a 3-wire connection.
A
B
C
D
E
F
H
G
I
A
B
C
D
E
F
H
G
I
A
B
C
D
E
F
H
G
I
A.
Cable from home power supply
B.
Red wires
C.
Green (or bare) ground wire from
cooktop
D.
3-wire cable (from cooktop)
E.
Junction box
F.
White wire (from home power supply)
G.
UL listed wire connector
H.
Black wires
I.
UL listed or CSA approved conduit
connector with wire bushing
1.
Connect the 2 red wires (B) together
using a UL listed wire connector.
2.
Connect the green (or bare) ground wire
(C) from the cooktop cable to the green
(or bare) ground wire (in the junction box)
using a UL listed wire connector.
3.
Put a UL listed wire connector on the
end of the white wire (F).
NOTE:
Do not connect the green (or
bare) ground wire to the neutral (white)
wire in the junction box.
4.
Connect the 2 black wires (H) together
using a UL listed wire connector.
5.
Install junction box cover
.
1.
Connect the 2 red wires (B) together
using a UL listed wire connector.
2.
Connect the green (or bare) cooktop
cable wire (C) to the white (neutral) wire
(F) in the junction box using a UL listed
wire connector.
3.
Connect the 2 black wires (H) together
using a UL listed wire connector.
4.
Install junction box cover.
Summary of Contents for 7371/945
Page 59: ...59 ESPA OL...
Page 81: ......