background image

22

Other functions:

-  After  30  hours  of  appliance  operation,  the  pushbutton  panel  indicates  saturation  of  the 

grease filters by the buttons flashing. To reset, press the timer button.

-   After  4  hours  of  continuous  operation  from  the  last  setting,  the  appliance  turns  off  and 

closes automatically.

-  When the front panel is removed for cleaning and maintenance operations, all the electronic 

aspiration and movement functions are locked.

-  Anti pinching safety device: if anything is obstructing the closure operation of the down-

draft, the operation will stop and the downdraft will move up again.

Summary of Contents for 2451 000

Page 1: ...escello RE Italy tel 39 0522 687425 tel Servizio Assistenza 39 0522 684450 fax 39 0522 686019 fax Servizio Ricambi 39 0522 962166 e mail service fosterspa com www fosterspa com USER S MANUAL FOR SCUTI...

Page 2: ...tial negative consequences for the environment and hu man health which could otherwise be caused by inappropriate waste handling of this product For more detailed information about recycling of this p...

Page 3: ...cription of the applianc 17 2 INSTALLING THE HOOD Mounting the hood 18 Removal of the filter cartridge 19 Mounting the filter cartridge 19 Electrical hook up of the hood 20 3 HOW THE HOOD WORKS 21 4 C...

Page 4: ...rom non electrical sources so that the hood does not ventilate these combustion fumes It is prohibited to cook food over open flames or operate gas hobs without pots or pans on them under the hood its...

Page 5: ...17 1 TO THE ATTENTION OF THE USER EN DESCRIPTION OF THE APPLIANCE...

Page 6: ...stallation and connecting the appliance to the mains electricity lift the down draft and remove the door block Fig 5 6 7 Then open the door Fig 8 9 remove the PVC grease filter shield Fig 10 then plac...

Page 7: ...stallation must conform to the regulations in force regarding the ventilation of en closed environments In particular discharged air must not be channelled into a conduit used for exhaust discharge or...

Page 8: ...ct ground connection The fuse used must be 10 or 16 A If the power cable is damaged call the after sales service to avoid any risk Attention If the hood presents some form of anomaly unplug the applia...

Page 9: ...on panel 10 minutes after it has been enabled Model SDD3 TOUCH CONTROL VERSION Fig 15 OFF switch Fig 15 It is used to close the aspiration panel completely or to position it at inter mediate heights a...

Page 10: ...s of continuous operation from the last setting the appliance turns off and closes automatically When the front panel is removed for cleaning and maintenance operations all the electronic aspiration a...

Page 11: ...ry with a soft cloth Grease filter After 30 hours operation the button pad will sig nal that the grease filter is saturated by flashing the 4 speed LEDs Press the timer button to reset The grease filt...

Page 12: ...carbon filter is not worn hood n recirculation mode The hood stops in the middle of ope ration Check that there is not a power outage the omnipolar device has not tripped Any maintenance on your equip...

Page 13: ...65 1 2 3 4 6 5...

Page 14: ...66 7 8 9 10 11 Pusch...

Page 15: ...67 12 13 14 14 bis 15...

Page 16: ...68 16 17 18 19 20 21...

Page 17: ...69 22 A B C D E F...

Reviews: