PROTECTION AGAINST SOLIDS AND 

WATER  

Only for IP-rated fixtures 

 

The protection level of a housing is set by applied standards. For classification there is used the IP-Code. 

It contains the declaration „IP“and two following numbers. The first number characterizes the protection 

against harmful effects of solids, the second is rating the water protection. It is important to distinguish 

whether encapsulation and harmful effect! There can be housing that is not capsuled completely but still 

avoids harmful effect of solids or water.  

PROTECTION EXAMPLES: 

 

IP20:

  Protection against intruding objects >12,5mm „Finger protected “; No waterproofing. 

TYPICAL 

PROTECTION FOR INDOOR USE FIXTURES 

 

IP33

: Protection against intruding objects >2,5mm; Falling water within an angle of 60° has no harmful 

effect 

TYPICAL PROTECTION OF LED-LIGHTS USING RECESSED POWERCON AND DMX SOCKET

. This 

protection is linked to the mounting position of the fixture and always refers to typical mounting situation 

like a Floor spot used standing on the ground.  

IP54

: complete protection against solids and low-pressure water from any side 

THIS TYPE OF FIXTURES 

CAN BE USED UNDER NORMAL OUTDOOR CONDITIONS

.  

IP65

: shielded against dust and pressurized water from any side. 

TYPICAL PROTECTION FOR OUTDOOR 

RATED EVENTFIXTURES USING WATERPROOFED POWER AND SIGNAL LINK. 

 

IP67

: shielded against dust and protected for accidental briefly submerge. 

PROTECTION AGAINST 

ACCIDENTIAL SUBMERGING ON TEMPORARY FLOODED AREA. 

 

 

 

TEMPORARY USE  

  

Event equipment is designed for temporary use. This are typical purpose as concerts, festivals, theatre, 

clubs and disco use and referable venues. Long-term use, specially under outdoor conditions and fixed 

outdoor installation can bring damage in aging materials and affect the coated surface. Sealings as well 

as cables are made from rubber material and will age by long-term UV-emission as sunlight and should 

be checked frequently.  

  

Summary of Contents for FOS BAR Pente

Page 1: ...1 FOS BAR Pente...

Page 2: ...acket 86 mm the bar only Height 148 mm with the bracket Weight 5 Kg SAFETY WARNING This product must be installed by a qualified professional All maintenance must be carried out by a qualified electri...

Page 3: ...CKET This protection is linked to the mounting position of the fixture and always refers to typical mounting situation like a Floor spot used standing on the ground IP54 complete protection against so...

Page 4: ...cture using a standard mounting clamp Please note that when hanging the unit a safety cable should also be used UPRIGHT The fixture can be mounted in an upright or sitting position using the supportin...

Page 5: ...itivity 0 99 R000 Red dimming from 0 to 255 G000 Green dimming from 0 to 255 B000 Blue dimming from 0 to 255 W000 White dimming from 0 to 255 Y000 Amber dimming from 0 to 255 ID00 Fixtures ID Useful w...

Page 6: ...46 55 Pattern 2 56 65 Color Selection 66 75 Color Jump 76 85 Gradient 86 245 Auto Patterns in combination with channel 4 5 246 255 Sound Mode 4 Pattern Selection 5 Pattern Choice Speed 6 Red 7 Green 8...

Page 7: ...9 LED 2 White 10 LED 2 Amber 11 LED 3 Red 12 LED 3 Green 13 LED 3 Blue 14 LED 3 White 15 LED 3 Amber 16 LED 4 Red 17 LED 4 Green 18 LED 4 86 LED 18 Red 87 LED 18 Green 88 LED 18 Blue 89 LED 18 White 9...

Page 8: ...ce Speed 6 Red 7 Green 8 Blue 9 White 10 Amber 19 LED 1 Red 20 LED 1 Green 21 LED 1 Blue 22 LED 1 White 23 LED 1 Amber 24 LED 2 Red 25 LED 2 Green 26 LED 2 Blue 27 LED 2 White 28 LED 2 Amber 29 LED 3...

Page 9: ...moist cloth Never use liquids or force water After cleaning let the fixture dry before use The product is for indoor use only Always turn off unplug power and allow fixture to cool before servicing En...

Reviews: