background image

1

Operating Instructions: Photoelectric Blocking - PBL

Description

Fortress’ PBL prevents unexpected start-up in areas safeguarded 

by light curtains, an individual takes the safety key when entering 

the area and while they have that key on their person the light 

curtain remains blocked and therefore the protective stop function is 

maintained, this ensures the hazard cannot be reset or restarted until 

the key is returned to the unit. PBL provides the same peace of mind 

for an operator entering past a light curtain as a safety key or interlock 

blocking device does with physical guards. Additional padlock points 

on the dustcover allow any subsequent individuals entering the area 

to apply their own means of control to the device.

As a purely mechanical component complete with an integrated 

mounting plate it is easily retrofitted or added to an existing system, 

with a compatible light curtain, without the need for wiring or 

programming. 

Options & Ordering Information

Description

Part No.

PBL Device for left-hand blocking, with 100mm Blocker Plate and 

right-angled mounting bracket. 

PBL2A-1-1-CLSL-MP1 

PBL Device for right-hand blocking, with 100mm Blocker Plate and 

right-angled mounting bracket

PBL4A-1-1-CLSL-MP1

NOTICE! 

PBL is not an interlock and must only be used in addition to a light curtain as part of a safety related part of a control system 

that meets required reliability.

Important:

The PBL Photoelectric Blocking Device is designed for use according to the installation and operating instructions enclosed. 

It must be installed by competent and qualified personnel who have read and understood the whole of this document prior to 

commencing installation.

If the Device or guarded machinery equipment is used in a manner not specified by the manufacturer, the protection provided 

by the equipment may be impaired.

Any modification to or deviation from these instructions invalidates all warranties.

Fortress Interlocks Ltd accepts no liability whatsoever for any situation arising from misuse or misapplication of the Device.

The PBL device alone does not provide any protection from unexpected restart, it must only be used in addition to 

a compatible light curtain as part of a complete machine guarding system. The light curtain must meet all relevant 

safety requirements and applicable safety standards.

BEWARE OF INTENTIONAL MISUSE CAUSED BY OPERATORS WANTING TO BYPASS SAFETY SYSTEMS. THE 

INSTALLER SHOULD ASSESS THE RISKS AND MITIGATE AGAINST THEM.

In order to maintain device safety rating, overall machine guarding system must be validated to EN ISO 13849-2 and/or 

evaluated in accordance with IEC 62061.

IF YOU HAVE ANY QUESTIONS OR QUERIES OF ANY NATURE WHATSOEVER PLEASE CONTACT THE SUPPLIER 

WHO WILL BE PLEASED TO ADVISE AND ASSIST.

Summary of Contents for Osbourn PBL2A-1-1-CLSL-MP1

Page 1: ...ition to a light curtain as part of a safety related part of a control system that meets required reliability Important The PBL Photoelectric Blocking Device is designed for use according to the installation and operating instructions enclosed It must be installed by competent and qualified personnel who have read and understood the whole of this document prior to commencing installation If the De...

Page 2: ...o an Engaged position The Engaged position of the Blocker Plate is designed to block and interrupt the beam or signal of an associated Light Curtain or similar Photoelectric sensing device Once the Blocker Plate is in the Engaged position the Personnel Safety Key can be removed The removal of the Personnel Safety Key traps the Blocker Plate in its Engaged position until the Personnel Safety Key is...

Page 3: ...CKABLE DUSTCOVER PERSONNEL SAFETY KEY ROTATED CLOCKWISE BLOCKER PLATE IN RETRACTED POSITION DEVICE SIDE OF PBL MOUNTED TO THIS OR SIMILAR LIGHT CURTAIN MOUNTING PLATE PERSONNEL SAFETY KEY ROTATED ANTI CLOCKWISE BLOCKER PLATE IN ENGAGED POSITION BLOCKER PLATE PERSONNEL SAFETY KEY FORTRESS A company Halma www fortressinterlocks com THE COPYRIGHT OF THIS DRAWING BELONGS TO FORTRESS INTERLOCKS Ltd THE...

Page 4: ...RACTED PERSONNEL SAFETY KEY REMOVED BLOCKER PLATE ENGAGED BLOCKER PLATE IN RETRACTED POSITION BLOCKER PLATE IN ENGAGED POSITION Figure 4 Dimensional Drawing for PBL4A right hand blocking device FORTRESS A company Halma www fortressinterlocks com THE COPYRIGHT OF THIS DRAWING BELONGS TO FORTRESS INTERLOCKS Ltd THE CONTENT OF THIS DRAWING IS CONFIDENTIAL AND MUST NOT BE DISCLOSED TO ANY 3rd PARTY WI...

Page 5: ...nical Function test section for more details Mount the complete device only in the correctly assembled condition All mounting surfaces should be flat stable and suitable of providing a minimum of 10mm thread engagement or sufficient support to either an M8 Nut T Nut or M5 Nut T Nut The PBL device must be located so that all scheduled inspection and maintenance procedures are all easily possible Th...

Page 6: ...inst the ingress of foreign bodies such as swarf sand blasting shot etc The device is to be mounted away from the machine or by the use of anti vibration mountings in order to avoid the effects of vibration shock and bump Use in Dusty Environments Careful product selection is required which is best performed under the guidance of a Fortress Representative in order to assess the dust type and produ...