background image

English

INSTALLATION INSTRUCTIONS

In case of pressures over 5 BAR (~75 PSI), we 

recommend to use a pressure reducer. 

Before proceeding with the assembly, purge the 

hot  and  cold  water  pipes  so  as  to  avoid  the 

accumulation  of  dirt  and  impurities  that  could 

affect the function of the faucet.

FIG. 01

Remove  the  protection  covers  (1.A)  using  a 

screwdriver. Use the plug (1.B) if necessary.

  

FIG. 02

Fit  the  faucet  body  (2.A)  to  the  wall  with  the 

two  upper  outlets  pointing  towards  the  flow 

elements. Connect the hot water supply to the 

left inlet and the cold water supply to the right 

one.

FIG. 03 

The  depth  of  the  wall  niche  must  correspond 

(

wall  coating  included

)  to  the  tolerance  given 

by  the  MIN/MAX  references  given  on  the 

plastic cover (3.A).

Once  all  connections  have  been  carried  out, 

activate  the  faucet  at  the  working  pressure 

(we  recommend  maintaining  the  water  flow 

for  a  few  minutes  so  as  to  purge  the  system 

from any debris and/or dirt inside the piping). 

Temporarily  remove  the  protection  cover  (3.A) 

to check if there are leakages and if the system 

works  regularly,  reinstall  the  protection  cover 

(3.A) and finish the external wall surface. 

FIG. 04

Remove  the  protection  cover  (3.A)  as  shown 

in FIG. 03. With a screwdriver fasten the stop 

cocks (4.G) in clockwise direction, loosen the 

fitting screw (4.F) using the proper wrench and 

pull  out  the  test  plug  (4.D).  Insert  the  o-ring 

(4.C) and the sleeve (4.B) on the thermostatic 

body and protection cylinder (4.E). Use a small 

quantity of the special grease included to lightly 

lubricate the o-rings of the thermostatic cartridge 

(4.A). Insert the cartridge in the faucet housing 

carefully aligning the positioning hole with the 

housing  of  the  fitting  screw  (4.F),  then  tighten 

the latter.

Warning!

,  Do  not  force  the  screw  (4.F). 

Excessive  tightening  can  affect  the  correct 

function  of  the  system  or  damage  it.  The 

thermostatic cartridge is equipped with a safety 

anti-scalding retainer set at 100°F (38°C). For 

higher  temperatures  push  the  button  on  the 

adjustment handle. In case of hot or cold water 

pressure failure, the flow will automatically stop. 

With a screwdriver loosen the stop cocks (4.G) 

in anti-clockwise direction.

FIG. 05

Remove  the  protection  tape  of  the  adhesive 

sponge (5.D) and apply it on the back of the 

plate (5.C).

Fit the sliding flat washers (5.B) and (5.A) on 

the plate (5.C) and install it on the thermostatic 

body till it is flush to the wall.

FIG. 06

Control handles installation.

For the upper portion with the cartridge, follow 

the instructions given below:

Fit the insert (6.M) on the bar of the cartridge 

so as to obtain the correct alignment once the 

handle (6.G) has been installed and lock using 

the  screw  included  (6.L).  Fit  the  handle  (6.G) 

and tighten the grub screw (6.I). Complete by 

positioning the finishing cap (6.H).

For  the  lower  portion  with  the  thermostatic 

cartridge, follow the instructions given below:

fasten the peg (6.E) on the bar of the thermostatic 

cartridge  and  fit  the  spacer  (6.F).  Install  the 

handle (6.A) putting the ring (6.D) in between 

without moving the bar so as to not compromise 

the cartridge calibration. Tighten the grub screw 

(6.B) and place the finishing cap (6.C).

FIG. 07

To  replace  only  the  handle  (7.A)  follow  the 

instructions given below:

Remove the cap (7.C), loosen the grub screw 

(7.B) and pull out the handle (7.A).

Water Supply

Recommended

Maximum

Minimum

Hot Water Temperature

65 C° (~150F) 

80 C° (~175F)

15 C° (~60F)

Working Pressure

3 BAR (~45PSI)

5 BAR (~75PSI)

0.5 BAR (~7PSI)

P U R O   D E S I G N   I T A L I A N O

FIG. 01

FIG. 02

FIG. 06

FIG. 08

FIG. 05

FIG. 07

FIG. 03

FIG. 04

Istruz. art. 8969100.indd   4-6

26/04/11   11:10

Summary of Contents for San Marco 8969100

Page 1: ...pplication policy GARANTÍA LIMITADA DE POR VIDA PARA PRODUCTOS DE USO RESIDENCIAL FORTIS ofrece al comprador original las siguientes garantías para sus productos utilizados para instalaciones residenciales GARANTÍA PARTES MECÁNICAS FORTIS ofrece para todos los componentes mecánicos una Garantía Limitada de por vida que cubre los defectos de fabricación en los materiales y elaboración en condicione...

Page 2: ...ting screw 4 F then tighten the latter Warning Do not force the screw 4 F Excessive tightening can affect the correct function of the system or damage it The thermostatic cartridge is equipped with a safety anti scalding retainer set at 100 F 38 C For higher temperatures push the button on the adjustment handle In case of hot or cold water pressure failure the flow will automatically stop With a s...

Page 3: ...sen the grub screw 7 I and slide off the handle 7 M Remove the ring 7 N the lock nut 7 O the peg 7 P and the spacer 7 Q from the thermostatic cartridge 7 R Install the new thermostatic cartridge 7 R into the faucet housing carefully aligning the positioning hole with the grub screw housing Based on its policy of steady development Fortis reserves the right to change the characteristics of the prod...

Page 4: ...prueba 4 D tirándolo hacia el exterior Introducir el o ring 4 C en el cuerpo termostático el manguito 4 B luego atornillar el capuchón 4 E Luego utilizar la grasa especial en dotación para lubricar ligeramente los o rings del cartucho termostático 4 A Introducirla en el específico alojamiento del grifo prestando atención para hacer coincidir el orificio de posicionamiento con el alojamiento del to...

Page 5: ...sionero de fijación 7 B y extraer la maneta 7 A Después de haber extraído la placa 7 H atornillar en sentido horario las llaves de interrupción 7 T con la ayuda de un destornillador En caso de sustitución del cartucho termostático que incluye la maneta 7 X proceder de esta manera destornillar el tornillo prisionero de fijación 7 S y extraer del cuerpo el cartucho termostático que incluye la maneta...

Page 6: ...ras más elevadas es necesario presionar el botón que se encuentra en la maneta de regulación En caso de que cese la presión del agua caliente o fría el flujo se interrumpe automáticamente Mantenimiento de las superficies Durante la limpieza la superficie del grifo debe estar fría el calor acelera el desgaste de la superficie misma Asegurarse de que los productos para la limpieza no contengan ácido...