Environmental specifications

Ambient operating temperature: 0°C to 40°C 

Rack Mount Instructions - The following or similar rack-mount instructions are included with the installation instructions: 
Instructions de montage en rack - Les instructions de montage en rack suivantes ou similaires sont incluses avec les instructions d’installation: 

Elevated Operating Ambient

 - If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack environment may 

be greater than room ambient. Therefore, consideration should be given to installing the equipment in an environment compatible with the maximum 
ambient temperature (Tma) specified by the manufacturer.

Température ambiante élevée

 – S’il est installé dans un rack fermé ou à unités multiples, la température ambiante de fonctionnement de l’environne-

ment du rack peut être supérieure à la température ambiante de la pièce. Par conséquent, il est important d’installer le matériel dans un environnement 
respectant la température ambiante maximale (Tma) stipulée par le fabricant.

Reduced Air Flow

 - Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is 

not compromised.

Ventilation réduite

 – Installation de l’équipement dans un rack doit être telle que la quantité de flux d’air nécessaire au bon fonctionnement de 

l’équipement n’est pas compromise.

Mechanical Loading 

- Mounting of the equipment in the rack should be such that a hazardous condition is not achieved due to uneven mechanical 

loading.

Chargement Mécanique

 – Montage de l’équipement dans le rack doit être telle qu’une situation dangereuse n’est pas lié à un chargement mé-

canique inégal.

Circuit Overloading 

- Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of the 

circuits might have on overcurrent protection and supply wiring. Appropriate consideration of equipment nameplate ratings should be used when 
addressing this concern.

Surtension

 – Il convient de prendre l’ensemble des précautions nécessaires lors du branchement de l’équipement au circuit d’alimentation et être 

particulièrement attentif aux effets de la suralimentation sur le dispositif assurant une protection contre les courts-circuits et le câblage. Ainsi, il est 
recommandé de tenir compte des valeurs indiquées sur la plaque d’identification.

Reliable Earthing

 - Reliable earthing of rack-mounted equipment should be maintained. Particular attention should be given to supply connections 

other than direct connections to the branch circuit (e.g. use of power strips).

Fiabilité de la mise à la terre

 – Fiabilité de la mise à la terre de l’équipement monté en rack doit être maintenue. Une attention particulière devrait 

être accordée aux connexions d’alimentation autres que les connexions directes au circuit de dérivation (par exemple de l’utilisation de bandes de 
puissance).

Refer to specific Product Model Data Sheet for Environmental Specifications (Operating Temperature, Storage Temperature, Humidity, and Altitude)
Référez à la Fiche Technique de ce produit pour les caractéristiques environnementales (Température de fonctionnement, température de stockage, 
humidité et l’altitude).

Safety 

Battery

  – Risk of explosion if the battery is replaced by an incorrect type. Do not dispose of batteries in a fire. They may explode. Dispose of used 

batteries according to your local regulations. IMPORTANT: Switzerland: Annex 4.10 of SR814.013 applies to batteries.

Batterie 

 – Risque d’explosion si la batterie est remplacée par un type incorrect. Ne jetez pas les batteries au feu. Ils peuvent exploser. Jetez les piles 

usagées conformément aux réglementations locales. IMPORTANT: Suisse: l’annexe 4.10 de SR814.013 s’appliquent aux batteries.

警告
本電池如果更換不正確會有爆炸的危險
請依製造商說明書處理用過之電池

CAUTION:

There is a danger of explosion if a battery is incorrect replaced. Replace only with the same or equivalent type. 
Dispose batteries of according to the manufacturer’s instructions.
Disposing a battery into fire, a hot oven, mechanically crushing, or cutting it can result in an explosion.
Leaving a battery in an extremely hot environment can result in leakage of flammable liquid, gas, or an explosion.
If a battery is subjected to extremely low air pressure, it may result in leakage of flammable liquid, gas, or an explosion.

WARNUNG:

Lithium-Batterie Achtung: Explosionsgefahr bei fehlerhafter Batteriewechsel. Ersetzen Sie nur den gleichen oder gleichwertigen Typ. Batterien gemäß 
den Anweisungen des Herstellers entsorgen.

Beseitigung einer BATTERIE in Feuer oder einen heißen Ofen oder mechanisches Zerkleinern oder Schneiden einer BATTERIE, die zu einer EXPLO-
SION führen kann

Verlassen einer BATTERIE in einer extrem hohen Umgebungstemperatur, die zu einer EXPLOSION oder zum Austreten von brennbarer Flüssigkeit oder 
Gas führen kann

Eine BATTERIE, die einem extrem niedrigen Luftdruck ausgesetzt ist, der zu einer EXPLOSION oder zum Austreten von brennbarer Flüssigkeit oder 
Gas führen kann.

CAUTION: 

Shock Hazard. Disconnect all power sources.

ATTENTION: 

Risque d’électrocution. Débranchez toutes les sources d’alimentation.

Regulatory Notices 

 

Federal Communication Commission (FCC) – USA

This device complies with Part 15 of FCC Rules.  Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received; including interference that may cause undesired operation.

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules.  These limits are 
designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.  This equipment 
generates, uses, and can radiate radio frequency energy, and if it is not installed and used in accordance with the instruction manual, it may cause 
harmful interference to radio communications.  Operation of this equipment in a residential area is likely to cause harmful interference, in which case the 
user will be required to correct the interference at his own expense.

WARNING

: Any changes or modifications to this product not expressly approved by the party responsible for compliance could void the user’s 

authority to operate the equipment

Industry Canada Equipment Standard for Digital Equipment (ICES) – Canada

CAN ICES-3 (A) / NMB-3 (A)

This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations 
of the Canadian Department of Communications.

Cet appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la classe A prescrites 
dans le Règlement sur le brouillage radioélectrique édicte par le ministère des Communications du Canada.

Innovation, Science and Economic Development (ISED) – Canada

This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’s licence-ex-
empt RSS(s). Operation is subject to the following two conditions:

1.This device may not cause interference.
2.This device must accept any interference, including interference that may cause undesired operation of the device.

L’émetteur/récepteur exempt de licence contenu dans le présent appareil est conforme aux CNR d’Innovation, Sciences et Développement 
économique Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes:

1.L’appareil ne doit pas produire de brouillage;
2.L’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement.

This equipment complies with ISED radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operat-
ed with minimum distance 20cm between the radiator & your body.

Cet équipement est conforme aux limites d’exposition aux rayonnements ISED établies pour un environnement non contrôlé. Cet équipement doit être 
installé et utilisé avec un minimum de 20cm de distance entre la source de rayonnement et votre corps

European Conformity (CE) - EU

This is a Class A product. In a domestic environment, this product may cause radio interference, in which case the user may be required to take 
adequate measures.

 
The product transmits within the frequency ranges and less than or equal to the power listed below:

2402-2480MHz less than 20dBm

This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.  

Simplified EU Declaration of Conformity 

This declaration is only valid for Fortinet products (including combinations of software, firmware and hardware) provided by Fortinet or Fortinet’s au-
thorized partners to the end-customer directly for use within the EU or countries that have implemented the EU Directives and/or spectrum regulation. 
Any Fortinet products not obtained directly from Fortinet or Fortinet’s authorized partners may not comply with EU Directives and Fortinet makes no 
assurances for such products.

Български
Този продукт е в съответствие с Директива 2014/53/ЕС.

Česky 

Tento produkt je v souladu se směrnicí 2014/53/EU.

Dansk
Dette produkt er i overensstemmelse med direktiv 2014/53/EU.

Deutsch
Dieses Produkt entspricht der Richtlinie 2014/53/EU.

Eesti
See toode vastab direktiivile 2014/53/EL.

English
This product is in compliance with Directive 2014/53/EU.

Español
Este producto cumple con la Directiva 2014/53/UE.

Ελληνική

Το προϊόν αυτό συμμορφώνεται με την Οδηγία 2014/53/ΕΕ.

 

Summary of Contents for FortiGate 200F Series

Page 1: ...QuickStart Guide FortiGate 200F Series QuickStart Guide...

Page 2: ...neral Counsel with a purchaser that expressly warrants that the identified product will perform according to certain expressly identified performance metrics and in such event only the specific perfor...

Page 3: ...ormation refer to the Admin Guide on https docs fortinet com For contracts licensing product registration and account management contact FortiCare Support at https www fortinet com support contact Acc...

Page 4: ...ement Computer Note For a detailed CLI guide visit docs fortinet com USB Console Cable available for purchase CLI 1 1 2 2 3 3 Speed default 9600 Data bits 8 Stop bits 1 Parity None Flow Control None 6...

Page 5: ...Desktop Mount Rack Mount 1 5in 1 5in 1 5in 1 5in 1 2 3 Note The recommended clearance is 1 5 inches above and below the device Caution To avoid personal injury or damage to the device it is recommende...

Page 6: ...STATUS ALARM HA POWER Green Operating normally BLE is off Flashing Green Booting up BLE is on Red Major alarm Green Operating in an HA cluster Red HA failover Off HA disabled FortiGate MGMT RJ45 1GE M...

Page 7: ...Guide de d marrage rapide S rie FortiGate 200F 13 12 This page is intentionally left blank Cette page a t laiss e blanche intentionnellement Fran ais...

Page 8: ...signed by Fortinet s General Counsel with a purchaser that expressly warrants that the identified product will perform according to certain expressly identified performance metrics and in such event...

Page 9: ...on sur https docs fortinet com Pour obtenir de l aide avec les contrats les licences l enregistrement de produit et la gestion de compte communiquez avec le service FortiCare au https www fortinet com...

Page 10: ...tion N B Pour obtenir un guide d taill pour l interface de ligne de commande rendez vous sur docs fortinet com C ble de console USB vendu s par ment CLI 1 1 2 2 3 3 Vitesse par d faut 9600 Bits de don...

Page 11: ...bureau Montage sur b ti 1 5 po 4 cm 1 5 po 4 cm 1 2 3 N B On recommande de laisser un espace de 4 cm 1 5 po au dessus et en dessous de l appareil Attention Pour viter les blessures et les dommages l a...

Page 12: ...Fonctionnement normal BLE d sactiv Vert clignotant D marrage BLE activ Rouge Alarme majeure Vert Fonctionnement en grappe haute disponibilit Rouge Basculement vers la haute disponibilit teint Pas de...

Page 13: ...iner EXPLO SION f hren kann Verlassen einer BATTERIE in einer extrem hohen Umgebungstemperatur die zu einer EXPLOSION oder zum Austreten von brennbarer Fl ssigkeit oder Gas f hren kann Eine BATTERIE d...

Page 14: ...com a Diretiva 2014 53 UE Rumunski Acest produs este n conformitate cu Directiva 2014 53 UE Slovensky Tento produkt je v s lade so smernicou 2014 53 E Slovensko Ta izdelek je v skladu z Direktivo 2014...

Page 15: ...Fortinet com...

Reviews: