Fortinet FortiExtender 101F Quick Start Manual Download Page 10

18

Cautions and Warnings

Environmental specifications

Ambient operating temperature: 0°C to 40°C 

Refer to specific Product Model Data Sheet for Environmental Specifications (Operating Temperature, Storage Temperature, Humidity, and Altitude)

Référez à la Fiche Technique de ce produit pour les caractéristiques environnementales (Température de fonctionnement, température de stockage, 

humidité et l'altitude).

Safety 

Caution:  This equipment is to be used in a Network Environment 0 per IECTR 62101.  This product is connected only to PoE networks without routing to the 

outside plant.

Attention: Ce matériel doit être utilisé dans un Environnement Réseau 0 par IECTR 62101. Ce produit est uniquement connecté aux réseaux PoE sans 

installation externe de routage.

This product is intended to be supplied by a Listed Direct Plug-In Power Unit marked LPS or Class 2 and rated 12VDC, 2A or by 54 VDC from PoE source.

Le produit doit être alimenté par un bloc d'alimentation à courant continu homologué UL de 12VDC, 2A nominal marqué LPS ou Class 2 ou par une source 

d’alimentation par Ethernet de 54 VDC (PoE).

Regulatory Notices

Federal Communication Commission (FCC)—USA

This device complies with Part 15 of FCC Rules.  Operation is subject to the following two conditions:

1. 

This device may not cause harmful interference, and

2. 

This device must accept any interference received; including interference that may cause undesired operation.

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are 

designed to provide reasonable protection against harmful interference in residential installation.  This equipment generates, uses, and can radiate radio 

frequency energy, and if it is not installed and used in accordance with the instruction manual, it may cause harmful interference to radio communications.  

However, there is no guarantee that interference will not occur in a particular installation. 

If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user 

is encouraged to try to correct the interference by one or more of the following measures:

• 

Reorient or relocate the receiving antenna.

• 

Increase the separation between the equipment and receiver.

• 

Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

• 

Consult the dealer or an experienced radio/TV technician for help.

WARNING: 

 Any changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to 

operate the equipment

This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated 

with minimum distance 20cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other 

antenna or transmitter.

Industry Canada Equipment Standard for Digital Equipment (ICES)—Canada

This Class B digital apparatus complies with Canadian ICES-003.

Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.

Innovation, Science and Economic Development (ISED)—Canada

This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’s licence-exempt 

RSS(s). Operation is subject to the following two conditions:

1. 

This device may not cause interference.

2. 

This device must accept any interference, including interference that may cause undesired operation of the device.

L’émetteur/récepteur exempt de licence contenu dans le présent appareil est conforme aux CNR d’Innovation, Sciences et Développement économique 

Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes:

1. 

L’appareil ne doit pas produire de brouillage;

2. 

L’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement.

This equipment complies with ISED radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated 

with minimum distance 20cm between the radiator & your body.

Cet équipement est conforme aux limites d’exposition aux rayonnements ISED établies pour un environnement non contrôlé. Cet équipement doit être 

installé et utilisé avec un minimum de 20cm de distance entre la source de rayonnement et votre corps.

This radio transmitter operates with the antenna types listed below with the maximum permissible gain and required antenna impedance for each antenna 

type indicated. Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use 

with this device. 

Le présent émetteur radio pour fonctionner avec les types d'antenne énumérés ci-dessous et ayant un gain admissible maximal et l'impédance requise pour 

chaque type d'antenne. Les types d'antenne non inclus dans cette liste, ou dont le gain est supérieur au gain maximal indiqué, sont strictement interdits 

pour l'exploitation de l'émetteur.

This device and its antennas(s) must not be co-located or operating in conjunction with any other antenna or transmitter except in accordance with IC 

multi-transmitter product procedures.

Cet appareil et son antenne (s) ne doit pas être co-localisés ou fonctionnement en association avec une autre antenne ou transmetteur.

19

Summary of Contents for FortiExtender 101F

Page 1: ...QuickStart Guide FortiExtender 101F ...

Page 2: ...etrics contained herein were attained in internal lab tests under ideal conditions and actual performance and other results may vary Network variables different network environments and other conditions may affect performance results Nothing herein represents any binding commitment by Fortinet and Fortinet disclaims all warranties whether express or implied except to the extent Fortinet enters a b...

Page 3: ...s Internet WAN connection device featuring one 1 Gb 100 Mb WAN connection and four 1 Gb 100 Mb LAN connections Model Modem FEX 101F Quectel CAT6 EM06 A NA Quectel CAT6 EM06 E EU Notes LTE CAT6 module 300 Mbps downlink and 50 Mbps uplink Region EM06 A for North American EM06 E for EU Brazil APAC FEX 101F only supports MicroSIM 3FF SIM cards which are not included You must purchase your own SIM card...

Page 4: ...ed Green Flashing 1 Gb network activity Amber Steady 100 Mb network connected Amber Flashing 100 Mb network activity Off No network connection LAN Port LEDs Green Steady 1 Gb network connected Green Flashing 1 Gb network activity Amber Steady 100 Mb network connected Amber Flashing 100 Mb network activity Off No network connection SIM Card Bay Reset Default Button Button Operating Instructions Res...

Page 5: ...Flashing Rapidly System is in error state OFF Modem is powered off or no LTE connection Management Blue Steady System is managed by FortiGate or FortiExtender Cloud Blue Flashing System is connecting to a management device OFF System is not connected to any FortiGate device FortiSASE LAN Extension Blue Steady System is connected to FortiSASE LAN Extension Blue Flashing at one second intervals Syst...

Page 6: ...when connected to LAN Port 4 of FortiExtender 3 Optionally if you are not using PoE connect the device to a power outlet using a power adapter LAN PoE Internet Warning You must provide adequate grounding to the PoE injector of the FortiExtender unit if required in compliance with your local electrical code or regulations This device complies with IEEE 802 3af at PoE specification Do not use a PoE ...

Page 7: ...s to obtain an IP address from a DHCP server If you do not use DHCP you can configure a static IP address To configure a static IP address 1 Use an Ethernet cable to connect one of the LAN ports to the Ethernet port of your computer 2 Set the computer Ethernet port to DHCP mode and connect it to port1 port2 or port3 3 Open your web browser and point to the default FortiExtender web GUI address htt...

Page 8: ... the best LTE signal strength Refer to the diagram below for proper placement and mounting Place on top of a desk or flat surface 1 Attach the rubber feet to the four corners on the bottom of the unit 2 Place the unit on the desk or flat surface 3 Secure the unit in place with a Kensington lock 4 Attach the antennas ...

Page 9: ...p Use bear claw screws The screw heads of bear claw screws have a built in gap that fits well with the hanging holes You can purchase bear claw screws from a local or online hardware store Fasten onto a wall 1 Peel off the drill template sticker and stick it onto the wall in a desired location 2 Use the template to mark and drill the pilot holes 3 Insert the anchors into the holes 4 Snap off the p...

Page 10: ...ipment This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment This equipment should be installed and operated with minimum distance 20cm between the radiator and your body This transmitter must not be co located or operating in conjunction with any other antenna or transmitter Industry Canada Equipment Standard for Digital Equipment ICES Canada This Cl...

Page 11: ...me alla Direttiva 2014 53 EU Latviski Questo prodotto è conforme alla Direttiva 2014 53 EU Lietuvių 20 Šis gaminys atitinka direktyvą 2014 53 ES Malti Dan il prodott huwa konformi mad Direttiva 2014 53 UE Magyar Ez a termék megfelel a 2014 53 EU irányelvnek Nederlands Dit product is in overeenstemming met Richtlijn 2014 53 EU Norsk Dette produktet er i samsvar med direktiv 2014 53 EU Polski Ten pr...

Page 12: ...cumentation including license term restrictions and solely on the Fortinet appliance or in the case of blades CPUs or databases on the single blade CPU or database on which Fortinet installed the Software or for stand alone Software solely on a single computer running a validly licensed copy of the operating system for which the Software was designed unless and except set forth in the published do...

Page 13: ...iginal shipment unless otherwise agreed in writing by Fortinet 8 Governing Law Any disputes arising out of this Agreement or Fortinet s limited warranty shall be governed by the laws of the state of California without regard to the conflict of laws principles In the event of any disputes arising out of this Agreement or Fortinet s limited warranty the parties submit to the jurisdiction of 24 the f...

Page 14: ...ust be on the terms of this License whose permissions for other licensees extend to the entire whole and thus to each and every part regardless of who wrote it Thus it is not the intent of this section to claim rights or contest your rights to work written entirely by you rather the intent is to exercise the right to control the distribution of derivative or collective works based on the Program I...

Page 15: ... not bring the other work under the scope of this License 3 You may opt to apply the terms of the ordinary GNU General Public License instead of this License to a given copy of the Library To do this you must alter all the notices that refer to this License so that they refer to the ordinary GNU General Public License version 2 instead of to this License If a newer version than version 2 of the or...

Page 16: ...o make thoroughly clear what is believed to be a consequence of the rest of this License 12 If the distribution and or use of the Library is restricted in certain countries either by patents or by copyrighted interfaces the original copyright holder who places the Library under this License may add an explicit geographical distribution limitation excluding those countries so that distribution is p...

Page 17: ...net products https docs fortinet com Training Services Course descriptions availability schedules and location of training programs in your area https training fortinet com Technical Discussion Forums Communicate with other customers and Fortinet partners about Fortinet products services and configuration issues https forum fortinet com FortiGuard Threat Research and Response Up to date informatio...

Reviews: