Connecting to the FortiController-5913C GUI

Basic Configuration

FortiController-5913C Session-Aware Load Balancing Cluster (SLBC) System Guide

22

10-500-259409-20160210

http://docs.fortinet.com/

 

Licenses (Support, FortiGuard, FortiCloud, FortiClient, FortiToken Mobile, 
VDOMs)

Register and apply licenses to each worker before adding the worker to the SLBC cluster. 
This includes FortiCloud activation, FortiClient, and FortiToken licensing, and entering a 
license key if you purchased more than 10 Virtual Domains (VDOMS).

Certificates

You can also install any third-party certificates on the primary worker before forming the 
SLBC cluster. Once the cluster is formed third-party certificates are synchronized to all 
workers.

Connecting to the FortiController-5913C GUI

You can connect to the FortiController-5913C GUI by browsing to the 
FortiController-5913C mgmt interface IP address. From the FortiController-5913C GUI 
you can add workers to the cluster and configure load balancing settings. 

By default, you can connect to the FortiController-5913C GUI by browsing to 
https://192.168.1.99.

Connecting to the FortiController-5913C CLI

You can connect to the FortiController-5913C CLI using the serial connector that came 
packaged with your FortiController-5913C board or an Ethernet connection to the mgmt 
interface.

To connect to the CLI over an Ethernet network use SSH to connect to the mgmt port 
(default IP address 192.168.1.99).

To connect to the CLI using a serial console connection

1

Connect the FortiController-5913C unit’s Console port to the serial communications 
(COM) port on your management computer using a serial cable (or using an RS-232 to 
USB convertor).

2

Start the terminal emulation application and configure the following settings.

• Bits per second: 9600

• Data bits: 8

• Parity: None

• Stop bits: 1

• Flow control: None

3

Press Enter to connect to the CLI.

4

Type a valid administrator account name (such as admin) and press Enter.

5

Type the password for that administrator account and press Enter. (In its default state, 
there is no password for the admin account.)

The CLI displays the following text:

Welcome!

Type ? to list available commands.

Summary of Contents for FortiController-5913C

Page 1: ...ortiGate 5000 series documents are available from the FortiGate 5000 page of the Fortinet Technical Documentation web site http docs fortinet com Access to Fortinet customer services such as firmware...

Page 2: ...t is grounded This includes supply connections e g power strips not only direct connections to the branch circuit Mise la terre Assurez vous que tout l quipement est mis la terre Ceci comprend les con...

Page 3: ...own and Removing a FortiController 5913C board 17 Resetting a FortiController 5913C board 19 Troubleshooting 20 FortiController 5913C does not startup 20 FortiController 5913C status LED is flashing d...

Page 4: ...n 28 Customer service and support 28 Fortinet products End User License Agreement 28 Regulatory Notices 30 Federal Communication Commission FCC USA 30 Industry Canada Equipment Standard for Digital Eq...

Page 5: ...FortiGate 5001D workers can handle up to 40 Gbps of traffic FortiGate 5001B and FortiGate 5101C workers can handle up to 10 Gbps The FortiController 5913C can also provide 40 gigabit fabric and 1 gig...

Page 6: ...istribute sessions to workers installed in chassis slots 3 to 14 The speed of these interfaces cannot be changed You may need to use attenuators on these single or split interfaces if their optical po...

Page 7: ...shing Amber Network activity Off No link is established B1 and B2 Green The correct cable is connected to the interface and the connected equipment has power Flashing Green Network activity at the int...

Page 8: ...he same chassis can be added for redundancy or to increase the number of network interfaces You can also add a second chassis for chassis redundancy Table 2 FortiController 5913C connectors Connector...

Page 9: ...ons One FortiController 5913C and up to 12 workers The FortiController 5913C receives all sessions and load balances them to the workers If the FortiController 5913C fails the cluster fails Two FortiC...

Page 10: ...ler 5913C and up to 12 workers in each chassis The FortiController 5913C in one chassis receives all sessions and load balances them to the workers in that chassis If that FortiController 5913C fails...

Page 11: ...m a two chassis SLBC where each chassis would include a FortiController 5913C in slot 1 and optionally a second FortiController 5913C in slot 2 You then install the workers in slots 3 and up in each c...

Page 12: ...Controller 5913C session aware load balancing SALB FortiController 5913C system FortiController 5913C Session Aware Load Balancing Cluster SLBC System Guide 12 10 500 259409 20160210 http docs fortine...

Page 13: ...nstall SR SFP transceivers for normal operation of FortiController 5913C B1 and B2 front panel interfaces The FortiController 5913C ships with two SR SFP transceivers You can also configure the B1 and...

Page 14: ...right bottom of the FortiController 5913C front panel The mounting components on the left top of the front panel are the same but reversed The FortiController 5913C mounting components align the boar...

Page 15: ...ard power on and start up correctly FortiController 5913C boards are hot swappable The procedure for inserting a FortiController 5913C board into a chassis slot is the same whether or not the chassis...

Page 16: ...sides of the chassis slot Closing the handles draws the FortiController 5913C board into place in the chassis slot and into full contact with the chassis backplane The FortiController 5913C front pane...

Page 17: ...ontroller 5913C mounting components described in FortiController 5913C mounting components on page 14 to remove a FortiController 5913C board from an ATCA chassis slot FortiController 5913C boards are...

Page 18: ...s flashing and becomes solid blue 7 Open the handles to their fully open positions Opening the handles turns off the microswitch turns off all LEDs and ejects the board from the chassis slot You need...

Page 19: ...the FortiController 5913C board to use this procedure To complete this procedure you need An ATCA chassis with a FortiController 5913C board installed An electrostatic discharge ESD preventive wrist...

Page 20: ...ortiController 5913C board is receiving power and the handles are fully closed and you have restarted the chassis and the FortiController 5913C still does not start up the problem could be with FortiO...

Page 21: ...hould indicate that the boards are functioning normally This chapter includes the following topics SLBC licensing Connecting to the FortiController 5913C GUI Connecting to the FortiController 5913C CL...

Page 22: ...alancing settings By default you can connect to the FortiController 5913C GUI by browsing to https 192 168 1 99 Connecting to the FortiController 5913C CLI You can connect to the FortiController 5913C...

Page 23: ...ler 5913C board in chassis slot 1 3 Install the workers in chassis slots 3 4 and 5 4 Power on the chassis 5 Check the chassis and board LEDs to verify that all components are operating normally 6 Chec...

Page 24: ...as the FortiController 5913C management IP address 12 Connect FortiController 5913C front panel interface F1 to the Internet and front panel interface F2 to the internal network The workers see these...

Page 25: ...nto the FortiController 5913C GUI going to Load Balance Status and selecting the Config Master icon beside the primary worker which is always the top entry in the Worker Blade list Using the external...

Page 26: ...e workers in the cluster in a single operation from the worker web based manager The firmware running on all of the workers in the cluster is updated simultaneously 1 Log into the worker web based man...

Page 27: ...ssage Running Slot 6 Status Working Function Active Link Base Up Fabric Up Heartbeat Managment Good Data Good Status Message Running Slot 8 Status Working Function Active Link Base Up Fabric Up Heartb...

Page 28: ...ubleshooting how to articles examples FAQs technical notes and more Visit the Fortinet Knowledge Base at http kb fortinet com Comments on Fortinet technical documentation Send information about any er...

Page 29: ...press or implied except to the extent Fortinet enters a binding written contract signed by Fortinet s General Counsel with a purchaser that expressly warrants that the identified product will perform...

Page 30: ...this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense WARNING Any changes or modifications...

Reviews: