background image

# LED

State

Description

1 Power

Green

The unit is on.

Off

The unit is off.

2 Status

Green

The unit is running normally.

Flashing Green

The unit is booting.

Amber

The unit has a fault.

3 WiFi

Green

Wireless radio is active.

Off

Wireless interface is down.

4 WAN 1 & 2

Green

Port is connected at 1Gbps.

Amber

Port is connected at 
10/100Mbps.

Flashing Green

Link activity at 1Gbps.

Flashing Amber

Link activity at 10/100Mbps.

Off

No link established.

5

Ethernet 
Ports 1 - 8

Green

Port is connected at 1Gbps.

Amber

Port is connected at 
10/100Mbps.

Flashing Green

Link activity at 1Gbps.

Flashing Amber

Link activity at 10/100Mbps.

Off

No link established.

LED Specifications

Page 10

FortiAP 28C

2

1

1

7

3

6

4

MGMT

5

8

2

1 2

4

3

5

Cautions and Warnings

Please review the following cautions and warnings.

Environmental and mounting specifications

Operating temperature: 0 - 40°C (32 - 104°F)
Storage temperature: -25 - 70°C (-13 - 158°F)
Humidity: 20 to 90% non-condensing
Altitude: <2250m (7400ft)

Elevated Operating Ambient:

 If installed in a closed or multi-unit rack assembly, the operating 

ambient temperature of the rack environment may be greater than room ambient. Therefore, 
consideration should be given to installing the equipment in an environment compatible with 
the maximum ambient temperature (T

ma

) specified by the manufacturer.

Circuit Overloading:

 Consideration should be given to the connection of the equipment to 

the supply circuit and the effect that overloading of the circuits might have on overcurrent 
protection and supply wiring. Appropriate consideration of equipment nameplate ratings 
should be used when addressing this concern. 

Federal Communication Commission (FCC) – USA

This device complies with Part 15 of FCC Rules.  Operation is subject to the following two 
conditions: (1) this device may not cause harmful interference, and (2) this device must accept 
any interference received; including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital 
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable 
protection against harmful interference in residential installation.  This equipment generates, 
uses, and can radiate radio frequency energy, and if it is not installed and used in accordance 
with the instruction manual, it may cause harmful interference to radio communications.  
However, there is no guarantee that interference will not occur in a particular installation. 
If this equipment does cause harmful interference to radio or television reception, which can be 
determined by turning the equipment off and on, the user is encouraged to try to correct the 
interference by one or more of the following measures:

Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver 
is connected.
Consult the dealer or an experienced radio/TV technician for help.

WARNING

: Any changes or modifications to this unit not expressly approved by the party 

responsible for compliance could void the user’s authority to operate the equipment

Radiation Exposure Statement:

This equipment complies with FCC radiation exposure limits set forth for an uncontrolled 
environment. This equipment should be installed and operated with minimum distance 21cm 
between the radiator and your body. This transmitter must not be co-located or operating in 
conjunction with any other antenna or transmitter.

Caution

: Operations in the 5.15-5.25GHz band are restricted to indoor usage only.

Page 11

Summary of Contents for FortiAP 28C

Page 1: ...FortiAP 28C QuickStart Guide...

Page 2: ...ortinet s General Counsel with a purchaser that expressly warrants that the identified product will perform according to certain expressly identified performance metrics and in such event only the spe...

Page 3: ...WiFi client access that creates a fortified WLAN network that is centrally managed by a FortiGate or FortiWiFi platform Your box contains the following FortiAP 28C Product Documentation with Mounting...

Page 4: ...curity slot to attach a cable lock cable lock is not included to protect your FortiAP device from unauthorized removal You can now proceed with connecting your FortiAP unit P3 5x32 Screw Anchor Page 2...

Page 5: ...FortiExplorer Easy Configuration Utility opens when the USB cable is connected Select Install the hardware automatically and select Next 4 After a moment FortiExplorer will launch FortiAP 28C 2 1 1 7...

Page 6: ...n be configured to use a static IP address To enable the FortiAP using Zero Configuration 1 After connecting the FortiAP unit as described in the previous chapter the unit goes through its boot proced...

Page 7: ...e with a question mark in the Status column 10 Select the access point and click Edit 11 In the State field select Authorize 12 In the Edit FortiAP dialog box select Enable Wireless Radio Leave the re...

Page 8: ...es Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause u...

Page 9: ...ed to take adequate measures Grounding Ensure your Fortinet product is connected and properly grounded to a lightning and surge protector WAN or LAN connections that enter the premises from outside th...

Page 10: ...yees and contractors from attempting to a modify translate reverse engineer decompile disassemble create derivative works based on sublicense or distribute the Software b rent or lease any rights in t...

Page 11: ...hom the waiver is asserted If any part of this Agreement is found unenforceable that part will be enforced to the maximum extent permitted and the remainder shall continue in full force and effect You...

Page 12: ...Library but is designed to work with the Library by being compiled or linked with it is called a work that uses the Library Such a work in isolation is not a derivative work of the Library and theref...

Page 13: ...FortiAP 28C Mounting Template...

Page 14: ......

Reviews: