# LED
State
Description
1 Power
Green
The unit is on.
Off
The unit is off.
2 Status
Green
The unit is running normally.
Flashing Green
The unit is booting.
Amber
The unit has a fault.
3 WiFi
Green
Wireless radio is active.
Off
Wireless interface is down.
4 WAN 1 & 2
Green
Port is connected at 1Gbps.
Amber
Port is connected at
10/100Mbps.
Flashing Green
Link activity at 1Gbps.
Flashing Amber
Link activity at 10/100Mbps.
Off
No link established.
5
Ethernet
Ports 1 - 8
Green
Port is connected at 1Gbps.
Amber
Port is connected at
10/100Mbps.
Flashing Green
Link activity at 1Gbps.
Flashing Amber
Link activity at 10/100Mbps.
Off
No link established.
LED Specifications
Page 10
FortiAP 28C
2
1
1
7
3
6
4
MGMT
5
8
2
1 2
4
3
5
Cautions and Warnings
Please review the following cautions and warnings.
Environmental and mounting specifications
Operating temperature: 0 - 40°C (32 - 104°F)
Storage temperature: -25 - 70°C (-13 - 158°F)
Humidity: 20 to 90% non-condensing
Altitude: <2250m (7400ft)
Elevated Operating Ambient:
If installed in a closed or multi-unit rack assembly, the operating
ambient temperature of the rack environment may be greater than room ambient. Therefore,
consideration should be given to installing the equipment in an environment compatible with
the maximum ambient temperature (T
ma
) specified by the manufacturer.
Circuit Overloading:
Consideration should be given to the connection of the equipment to
the supply circuit and the effect that overloading of the circuits might have on overcurrent
protection and supply wiring. Appropriate consideration of equipment nameplate ratings
should be used when addressing this concern.
Federal Communication Commission (FCC) – USA
This device complies with Part 15 of FCC Rules. Operation is subject to the following two
conditions: (1) this device may not cause harmful interference, and (2) this device must accept
any interference received; including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in residential installation. This equipment generates,
uses, and can radiate radio frequency energy, and if it is not installed and used in accordance
with the instruction manual, it may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver
is connected.
Consult the dealer or an experienced radio/TV technician for help.
WARNING
: Any changes or modifications to this unit not expressly approved by the party
responsible for compliance could void the user’s authority to operate the equipment
Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled
environment. This equipment should be installed and operated with minimum distance 21cm
between the radiator and your body. This transmitter must not be co-located or operating in
conjunction with any other antenna or transmitter.
Caution
: Operations in the 5.15-5.25GHz band are restricted to indoor usage only.