Fortin E400 RF751W Quick Installation Manual Download Page 7

FUNCTION

MODE 1 

 

 DEFAULT

MODE 2

MODE 3  

MODE 4 

MODE 5 

   

MODE 6  

   

17

Domelight Delay

Disable

Enable Ignore door 

trigger (dome light) 

when arming or 

Remote-starting

18

Diesel Mode

Disable

Enable (20 seconds)

Delay between Ignition 

power up and Starter 

(crank).

Enable (10 seconds)

Delay between Ignition 

power up and Starter 

(crank).

Enable

No delay between 

Ignition power up and 

Starter (crank).

19

Turbo timer

Disable

Run 2 minutes.

Run 4 minutes.

20

Engine supervision:  

-Tachless - analog 

tach- Tach Data-

Link-

Tachless on crank and 

supervision Tach Data-

Link or analogic after

Tachless only. 

(   vehicles 

with automatic 

transmission only)

Analog Tach 

learning (see p.8 for 

programming)

Start (crank) 8 sec 

on tachless. (  

vehicles with automatic 

transmission only)

Start (crank) 8 sec + 

Supervision by 

Data-Link Tach (Data 

interface required)

Tach Data-Link only 

(Data interface 

required)

21

Start Attempts

2

1

3

22

— 

23

Master RESET

RESET all 

programming options 

by default. (Retains 

already programmed 

remote.)

24

Special

application

Disable

Application 1

Application 2

Application 3

25

Auxiliary 1 Output 

TRUNK

 --> LOCK

0.5 seconds & disarm 

alarm

0.5 seconds

10 sec latch or 

until a button is pressed.

20 sec latch or 

until a button is 

pressed.

30 sec latch or 

until a button is 

pressed.

Latch until shutdown

26

Hybrid mode

Gas / Diesel vehicle

Hybrid vehicle

27

Auxiliary 2 

Output

TRUNK

--> 

UNLOCK

0.5 seconds & disarm 

alarm

0.5 seconds

10 sec latch or until a 

button is pressed.

20 sec latch or until a 

button is pressed.

30 sec latch or until a 

button is pressed.

28

Manual transmission 
Neutral safety switch 

Special Application

No application

Enable (see p.4)

For manual transmission vehicles equipped with neutral safety switch. DO NOT CUT THE LOOP. 
Connect the auxiliary IN (Purple/White) to the neutral safety switch of the vehicle.

29

Alarm Duration

30 seconds

60 seconds

120 seconds

30

Valet code

Ignition ON

Valet button x3 times.

Ignition ON

Valet button x3 times

and x1 times 

3 seconds.

Ignition ON

Valet button x4 times

 and x1 times 3 seconds.

Ignition ON

Valet button x5 times

and x1 times 3 seconds.

Ignition ON

Valet button x6 times 

and x1 times 

3  seconds.

Ignition ON

Valet button x7 times 

and x1 times 3 sec.

Summary of Contents for E400 RF751W

Page 1: ...e Lt Green Lt Green Black 24 8 Ignition Starter Ignition Switch Aux 1 Aux 2 INPUT OUTPUT Arm Cut loop for automatic transmission mode External LED 2 pin Yellow 14 Orange 14 Pink 14 Black 18 Starter Ac...

Page 2: ...will flash rapidly On each Transmitter press and release the button then press and release the button FMH 2 W The LED will stop flashing for a second confirming programming Turn the Ignition OFF to e...

Page 3: ...n neutral position Open the hood Disengage the parking brake Note If the parking lights flash 3 times when Remote Starting Ready Mode is not enabled TO ENABLE COLD START MODE TO DISABLE COLD START MOD...

Page 4: ...llation of the product including either damage to the vehicle itself or to the remote starter module This module must be installed by a certified technician including all of the supplied safety device...

Page 5: ...ed remote to select the mode X The parklights will flash 1 6 times to confirm Turn the Igni tion off to exit programming The parklights will flash 4 times Within 5 sec Return to step 3 to programmed t...

Page 6: ...onds by default if MODE 2 or 3 is activated Passive arm 60 seconds if MODE 2 or 3 is activated Passive arm 120 seconds if MODE 2 or 3 is activated 10 Starter Kill Output Starter kill anti grind Anti g...

Page 7: ...plication Disable Application 1 Application 2 Application 3 25 Auxiliary 1 Output TRUNK LOCK 0 5 seconds disarm alarm 0 5 seconds 10 sec latch or until a button is pressed 20 sec latch or until a butt...

Page 8: ...ed by locking the doors Cancel ready mode when trunk open 34 Trunk output Pulse 0 5 seconds Pulse 2 5 seconds Unlock before trunk pulse 0 5 sec Trunk Output at ignition only 35 Door unlock Special app...

Reviews: