1. Power the unit On
• Once powered the device will automatically turn on.
• If the device hasn’t turned on, long press the setting button
to turn the unit On/Off
2. Register RF433 Accessories
• Press the connection button to enter connection mode, the
green and blue LED will be illuminated.
• Trigger the desired accessory once within the next 30
seconds. You will see the green LED flash 3 times; this
indicates the registration has been successful. If the blue
LED flashes 3 times, this indicates the accessory has already
been registered.
3. Clear all registered devices
• Press and hold the connection button until the green and
blue LEDs flash (for 5 seconds). All accessories registered
have been deleted from the repeater.
1. TX LED
• OFF: No RF signal is transmitting
• Blue continuous: In connection mode
• Blue flashing: Transmitting an RF signal
2. RX LED
• OFF: No RF signal is being received
• Green continuous: In connection mode
• Green flashing: Receiving an RF signal
3. Status LED
• OFF: Power off
• Red continuous: Operating mode, only transmitting
registered accessorie(s) signals
• Red flashing: Test mode, will transmit all
received signals.
Guidance
>Smart alarm accessories are specified at a maximum of 80 meters Line of Sight (LoS) in open air.
For every obstacle the signal strength is reduced.
> Battery life depends on working and environmental factors.
For more product information please visit the ESP website
For pairing instructions, please refer to the main Hub Manual.
LED Indicators;
Telephone : 01527 51 51 50
Fax: 01527 51 51 43
Email : [email protected]
Web : www.espuk.com
E&OE - Errors and omissions excepted.G21
Elite Security Products
Redditch B98 8YN