P a g e
|
36
7. Remove battery. Clean with a moist anti-static cloth to avoid electrostatic
discharge and explosion risk. Charge and check electrolyte level if
appropriate.
8. Clean out battery tray. Apply a thin film of petroleum jelly to terminals to
prevent corrosion.
9. Replacement is the reversal of removal. Ensure to replace/fit any vent pipes.
Leave at least one vent open otherwise there is an explosion risk. This also
applies to old batteries removed for disposal/recycling. Swap new battery
positive terminal protective cover to the old battery positive terminal to help
prevent short circuits and sparks.
Figure 18
Charging
1. Remove battery from machine, disconnect negative terminal first.
2. Ensure good ventilation.
3. Use suitable direct current mains chargers only.
4. Connect battery positive terminal to charger output positive. Connect the
negative terminal accordingly.
5. After connection, switch on charger. When charging is complete, switch off
charger then disconnect battery.
6. Charging current recommendation is 10% of the battery Ah power rating.
7. Use a charger with a constant charging voltage of 14.4V.
8. If the acid temperature rises above 38°C, stop charging.
9. The battery is fully charged when the charging voltage or acid specific gravity
has stopped rising for two hours.
1 TAKE-OFF BATTERY
TERMINALS FASTENED
WITH M6 SCREW
2 BATTERY
3 BATTERY CLAMP M8
SCREW
Summary of Contents for XR8P
Page 39: ...P a g e 38 Parts lists Hopper tray touch sensor ...
Page 41: ...P a g e 40 Chipping chamber assembly ...
Page 42: ...P a g e 41 Chipping chamber assembly Bottom feed ...
Page 43: ...P a g e 42 Chipping chamber assembly Bottom feed anvil ...
Page 48: ...P a g e 47 Top feed roller assembly ...
Page 52: ...P a g e 51 Traxion Track Base ...
Page 53: ...P a g e 52 Traxion Track Base Cradle ...
Page 55: ...P a g e 54 Electrical circuit diagram Mechanical touch sensor hopper ...