the MDAC board inside the MADA-2 that will allow you to change the level calibration for the DA
section.
Digital inputs
There are two digital inputs on the MADA-2. One is configured as an AES-3 or AES/EBU input, and
the other is an SPDIF input. The AES-3 input is a 110 ohm, transformer isolated, and balanced XLR
input. Pin #1 of this input is connected to chassis ground through a 0.1 mfd capacitor . The SPDIF
input is a 75 ohm single-ended RCA input.
Analog Outputs
The analog output of the MADA-2 are balanced and floating with an output impedance of less than 5
ohms. Either balanced or single-ended loads may be connected to the output of the MADA-2 without
problem. When a single-ended load (unbalanced) is used, be sure to take the signal between pin #2 (hot)
and pin #3 (cold) of the input XLR. Pin #1 can be connected to either of these pins if desired.
Connecting pin #1 to pin #2 will produce an output signal that is out of phase, so normally pin #1 is
connected to pin #3 for single-ended loads. Pin #1 can be left floating too.
MADA-2 Specifications:
ADC specifications:
Sample Rates available : 44.1k, 48k, 88.2k, 96k, 176.4k and 192k
Level Calibration : 0 dBu Input = -18 dBFs
(Other calibration levels available on request.)
Analog Input Impedance = greater than 10k ohm balanced
Maximum analog input level is a function level calibration (no analog clipping).
AES3 (XLR) digital output impedance = 110 ohm balanced floating
SPDIF (RCA) digital output impedance = 75 ohm balanced floating
WC output = +5V (TTL) unterminated. Requires 75 ohm load termination at load.
ADC Latency (Input to Output group delay):
Fs
Time
44.1k
1.6 ms
48k
1.48 ms
88.2k
967 us
96k
895 us
176k
660 us
192k
605 us