ReACT Operation and
User Manual
Tel.: +44 (0)1524 383320 | Web: www.forsbergpnt.com
Forsberg Services Ltd., North Quay Offices, Heysham Port, Heysham, LA3 2XF, United Kingdom.
Registered in Scotland (SC104949)
Template: FSL-19-200 v3.00 | Revision Date: 14.08.19
Page 11
A0072-09-0016 v2.00
©
Forsberg Services Ltd. 2020
5
ReACT Installation and setup
5.1
Power
The ReACT GNSS system requires an input supply voltage b9 VDC and +36 VDC.
5.2
ReACT NS
5.2.1
Mechanical Dimensions
Dimensions
116 mm x 116 mm x 85 mm
Weight
600 g
5.2.2
Connectivity Overview
GNSS COM 1
RS232 or RS422
GNSS COM3
RS232 or USB
VARF
EVENT2
GNSS COM2
RS232
PPS
Pwr
CAN NMEA2000
CONFIG
Figure 1 ReACT NS Connectivity Overview
5.2.3
Configuring the com ports: COM1 and USB/COM3
The configuration port allows for the ReACT GNSS COM1 and USB/COM3 to be configured. The
following commands can be sent to the ReACT through the configuration port to configure the
ReACT GNSS COM1 and USB/GNSS COM3.
1
1
The OEMStar receiver only allows for GNSS COM1 RS232/RS422 and USB to be enabled. COM3 is not
available on this receiver model.