15
WWW.FORNEYIND.COM
TIP:
Start in the top-left corner at F1 and continue down and over through F7 to setup weld parameters.
Once parameter is selected, use the dial to fine-tune settings. Pressing F7 steps through parameters;
Holding F7 for 3 seconds saves changes made to parameters for User Defined Programs only.
TIG DC SETUP
TIG AC SETUP
STICK SETUP
AC
DC
F1
F2
F3
F4
F5
F6
F7
TIG
PEDAL
PANEL
REMOTE
LOCAL
TIG-HF
CONSTANT
STICK-HS
HOT START
RAMP UP
(LOCAL)
CRATER FILL
(LOCAL)
RAMP DOWN
(LOCAL)
PULSE
(BASE CURRENT)
MAIN CURRENT
HS
(STICK)
AF
(STICK)
STICK-AF
ARC FORCE
PREFLOW
POSTFLOW
TIG-HF
START ONLY
FREQUENCY
HZ
BALANCE
% EN
BASIC FUNCTIONS
TIG FUNCTIONS
STICK
SELECT
CONTROL
PULSE
PULSE
MENU
PROGRAM
HOLD
STORE
PROGRAM
ON
OFF
SELECT
ADJUST
SELECT
POWER
TEMP
FAULT
PROGRAM - CURRENT - VALUE
INPUT OK
SELECT
V
in
SELECT
MENU
TO
MODIFY
CAT# 325
PULSE
PPS
% ON
AC
DC
F1
F2
F3
F4
F5
F6
F7
TIG
PEDAL
PANEL
REMOTE
LOCAL
TIG-HF
CONSTANT
STICK-HS
HOT START
RAMP UP
(LOCAL)
CRATER FILL
(LOCAL)
RAMP DOWN
(LOCAL)
PULSE
(BASE CURRENT)
MAIN CURRENT
HS
(STICK)
AF
(STICK)
STICK-AF
ARC FORCE
PREFLOW
POSTFLOW
TIG-HF
START ONLY
FREQUENCY
HZ
BALANCE
% EN
BASIC FUNCTIONS
TIG FUNCTIONS
STICK
SELECT
CONTROL
PULSE
PULSE
MENU
PROGRAM
HOLD
STORE
PROGRAM
ON
OFF
SELECT
ADJUST
SELECT
POWER
TEMP
FAULT
PROGRAM - CURRENT - VALUE
INPUT OK
SELECT
V
in
SELECT
MENU
TO
MODIFY
CAT# 325
PULSE
PPS
% ON
NO ACTION REQUIRED - DEFAULT SETTING IS DC
AC
DC
F1
F2
F3
F4
F5
F6
F7
TIG
PEDAL
PANEL
REMOTE
LOCAL
TIG-HF
CONSTANT
STICK-HS
HOT START
RAMP UP
(LOCAL)
CRATER FILL
(LOCAL)
RAMP DOWN
(LOCAL)
PULSE
(BASE CURRENT)
MAIN CURRENT
HS
(STICK)
AF
(STICK)
STICK-AF
ARC FORCE
PREFLOW
POSTFLOW
TIG-HF
START ONLY
FREQUENCY
HZ
BALANCE
% EN
BASIC FUNCTIONS
TIG FUNCTIONS
STICK
SELECT
CONTROL
PULSE
PULSE
MENU
PROGRAM
HOLD
STORE
PROGRAM
ON
OFF
SELECT
ADJUST
SELECT
POWER
TEMP
FAULT
PROGRAM - CURRENT - VALUE
INPUT OK
SELECT
V
in
SELECT
MENU
TO
MODIFY
CAT# 325
PULSE
PPS
% ON
TIG-HF CONSTANT
TIG-HF START ONLY
TIG-HF OFF
TIG-HF CONSTANT
TIG-HF START ONLY
TIG-HF OFF
HOT START
HOT START
ARC FORCE
FOOT PEDAL
PANEL
FOOT PEDAL
PANEL
NO ACTION REQUIRED - DEFAULT SETTING IS PANEL
USE MENU (F7) TO STEP THROUGH PULSE OPTIONS
USE MENU (F7) TO STEP THROUGH PULSE OPTIONS
NO LED (AC FUNCTIONS NOT AVAILABLE IN DC TIG)
USE DIAL TO ADJUST FREQUENCY
USE DIAL TO ADJUST BALANCE
STEP THROUGH PARAMETERS TO MAKE ADJUSTMENTS
SAVES PARAMETER CHANGES TO USER PROGRAMS ONLY
STEP THROUGH PARAMETERS TO MAKE ADJUSTMENTS
SAVES PARAMETER CHANGES TO USER PROGRAMS ONLY
Parameter Setup