Formula Sound GUARDIAN CX4 MK II User Manual Download Page 5

Internal options

 

N.B. Internal settings should be undertaken by skilled personnel only

.

 

  DISCONNECT THE UNIT FROM THE MAINS SUPPLY   

 

Remove the top case cover by removing 6 screws located at the sides of the unit and 2 screws located on the top of 
the unit. (Re-assemble in the reverse order) 

Refer to drawing 860PCB (towards the back of the manual) for positions of internal options. 

Mains Voltage 

The CX4 MkIII has been designed to operate on 220-240Vac or 110-120Vac.    A slide switch located on the PCB 
behind the mains input connector selects the operating voltage.    The voltage selected is displayed on the switch 
230 (220-240V) 115 (110-120). 

DAMAGE MAY RESULT IF THE UNIT IS CONNECTED TO THE WRONG SUPPLY VOLTAGE 

THIS UNIT MUST BE EARTHED 

Fuses 

Mains fuse sizes are 250mA anti surge for 220-240V operation and 500mA anti surge for 110-120Voperation.   

It is 

important for safety reasons that the correct fuse sizes are always used.

 

Phantom Power 

If phantom power is required for the priority microphone it may be selected on a jumper located rear left edge of the CX4 
looking from the front panel. Legend on the PCB indicates setting.   

Priority input selector 

The priority input selector is located behind the priority in/out sockets - two jumpers select mic or line input. A label 
showing the jumper positions is provided.    (Be sure to move both jumpers)   

The factory setting is for a Microphone input. 

Earth lift   

A jumper is provided to lift the audio common (0VE) from mains earth.    This may be necessary in some 
installations.    A skilled audio system specialist should determine if this is necessary, otherwise this should be left in 
the factory supplied or normal position. 

Limiter time constant 

As described in the noise limiter section a jumper is provided to allow some adjustment to the limiter speed. This 
jumper is located towards the left center of the PCB viewed from the front and is clearly labelled. 

Page 4 

Lime Technologies

 

http://limetechnologies.co.uk

Tel: 08712 233127

Summary of Contents for GUARDIAN CX4 MK II

Page 1: ...GUARDIAN CX4MKIII PRIORITY INTERFACE AND SOUND LEVEL CONTROL USERS MANUAL Lime Technologies http limetechnologies co uk Tel 08712 233127...

Page 2: ...l is available at the priority output socket This is so that a microphone which is in normal use i e DJ MC or comp re may also be used as the priority input Phantom power may be selected for the prior...

Page 3: ...ced back to the threshold level This limiter is controlled by the average programme content and is fairly slow acting so as not to reduce the dynamics of the music An internal jumper is provided to al...

Page 4: ...control 1 On the front panel PCB set PEAK and THRESHOLD presets for channel 1 2 fully clockwise and check the security loop is unbroken 2 Put music through the CX4 with Amplifiers at full volume and...

Page 5: ...at the correct fuse sizes are always used Phantom Power If phantom power is required for the priority microphone it may be selected on a jumper located rear left edge of the CX4 looking from the front...

Page 6: ...ion push button adjacent jumper position determines the type of reset auto or manual 12 Test momentary action push button For set up and testing Priority input Internally selectable Mic Line 18V Phant...

Page 7: ...C Mains Voltage selector switch slide switch D Peak level response CH 1 2 CX4 MKIII INTERNAL ADJUSTMENTS www formula sound co uk G Priority control protocol selection volts or contacts C E Peak level...

Page 8: ...EEC and 93 68 EEC BS EN 50082 1 BS EN 50081 1 PRODUCT TYPE GUARDIAN CX4 MKIII The CE mark was first applied in 1995 Signed B J Penaligon General Manager Attention The attention of the specifier purch...