Forms+Surfaces HELIO BOLLARD Installation/Wiring Instructions Download Page 1

HELIO

 BOLLARD

SURFACE MOUNT WITH J-BOLTS INSTALLATION & WIRING INSTRUCTIONS

page 1 of 4  |  Rev. 05-25-21

© 2021 Forms+Surfaces®  |  All dimensions are nominal. Specifications and pricing subject to change without notice. For the most current version of this document, please refer to our website at www.forms-surfaces.com.

T 800.451.0410  |  www.forms-surfaces.com

TOOLS NEEDED

MATERIALS INCLUDED

STEP BY STEP

Pour concrete footer

• Mix and pour concrete footer according 
   to concrete manufacturer’s instructions. 
• A sufficient footer size depends on frost 
   and other conditions to be determined by 
   the installer. 
• A minimum of a 13" diameter x 20" 
   deep footer is recommended. 

Insert J-bolt anchors

• Insert 1/2"-13 x 18" galvanized steel 
   J-bolt anchors (a) into concrete.
• Use template to position J-bolt 
   anchors in proper locations. Tops of 
   J-bolt anchors must be a minimum of 
   1-1/4" above concrete surface.
• Allow concrete to set completely, in
   accordance with concrete 
   manufacturer’s instructions, before 
   moving to step 3.

FOR ALL SURFACE MOUNT HELIO BOLLARDS

a

socket wrench

3/4

"

 socket

c

b

a

template

(upon request)

a

e

d

DIAMETER

a

DEPTH

1-1/4" 
MINIMUM

Prepare the incoming power

• Before pouring concrete footer, run  
   properly sized conduit and cabling to 
   each luminary location according to local 
   code requirements. Refer to figure  
   above for dimensions for conduit entry 
   envelope size and location on luminary. 
   

Forms+Surfaces is not responsible for 

   site preparation and footings

   Note: Conduit should not protrude more 
   than 2" above mounting surface. 

Ø2.5" Conduit
Entry Location

3X Slots for 
Anchor Bolts

Summary of Contents for HELIO BOLLARD

Page 1: ... 2 13 x 18 galvanized steel J bolt anchors a into concrete Use template to position J bolt anchors in proper locations Tops of J bolt anchors must be a minimum of 1 1 4 above concrete surface Allow concrete to set completely in accordance with concrete manufacturer s instructions before moving to step 3 FOR ALL SURFACE MOUNT HELIO BOLLARDS a socket wrench 3 4 socket c b a template upon request a e...

Page 2: ...rsion of this document please refer to our website at www forms surfaces com T 800 451 0410 www forms surfaces com Tighten nuts Use 3 4 socket and socket wrench to tighten all nuts until snug STEP BY STEP FOR ALL SURFACE MOUNT HELIO BOLLARDS Slide base onto J bolt anchors Slide base base plate over J bolt anchors and lower base to concrete level Attach base Slide 1 2 washer b then thread 1 2 13 nu...

Page 3: ...e color codes from junction box to bollard Tighten wire nuts until exposed wire ends are below bottom of wire nut Inspect all wiring and connections before Caution Light fixture rated for 120 277 VAC power Locate and prepare wires Note Installation should be performed only by qualified individuals Before proceeding with wiring of luminary check to ensure that all applicable site wiring and safety ...

Page 4: ...without notice For the most current version of this document please refer to our website at www forms surfaces com T 800 451 0410 www forms surfaces com Attach bollard to base plate Thread 5 16 18x1 tamper resistant flat head screws d into each hole Use provided T40 Torx bit for tamper resistant screws to tighten all screws until snug STEP BY STEP FOR ALL SURFACE MOUNT HELIO BOLLARDS d d 10 ...

Reviews: