2.3.7 Remove the 6 off screws to remove the burner gauze, then 4 off screws
to remove the ceramic support and finally 4 off burner mounting screws
as shown below in figure 8, then lift the burner unit clear of the firebox.
Fig. 8
Burner gauze -
held in position by
6 off screws
Creramic support -
held in position by
4 off securing
screws
Burner unit -
held in position
by 4 off securing
screws
2.3.8 With the burner removed from the firebox, plan the routing of the gas
supply pipe into the firebox. See overpage, section 2.3.9 for suggested
pipework routing.
15