![Formax FD 3300 Operation Manual Download Page 30](http://html1.mh-extra.com/html/formax/fd-3300/fd-3300_operation-manual_2320110030.webp)
24
Chapter 1 Before Operation
5-11. Function Setting screen
[1/3 FUNC Setting] screen
[6]
[8]
[7]
[1]
[2]
[3]
[5]
[4]
No.
Name
Function
[1]
Interval
Sets whether to use the interval (division) function or not.
[2]
D-Feed Detect
(Double Feed Detect)
Sets whether to perform double-feed detection or not.
[3]
Detection
Sets whether to perform paper stacked/standard size detection or not.
[4]
Feed Interval
Sets a feed interval.
[5]
Belt Convey Vol
Sets the amount of conveyance.
[6]
(Cancel) key
When touched, the display returns to the [Basic Settings] screen.
Press and hold to return to the [Ready] screen.
[7]
(Page forward) key
Moves to the next page.
[8]
(Page backward) key
Moves to the previous page.