Form NEFFES NFS-1000-U User Manual Download Page 10

10   

NEFFES Antiviral Air Purifier

 User Manual

DEVICE FUNCTIONS

1. On/Off

Connect the device to a power supply and press “ON/OFF” button on the control panel. The 

device will start running with the fan in the 1st stage.

When the device starts to run, the UV-C lamp will be in closed position.

Press the “UV-C” button in the keypad to turn on the lamp. When the lamp is on, the led 

near the “UV-C” lamp will turn on.

2. Speed Selection

The device has 5 different speed settings.

Each time you press the “FAN SPEED” button on the keypad on the device, the fan speed 

will up to the next level and the LEDs will light up one by one. For example, when the device 

is in the 3rd speed stage, all the 3 LEDs will light up.

When the fan is in the last stage, if the button is pressed once, the fan speed will switch to 

the 1st stage.

When the device works again after a power outage, it will resume the previous mode.

3. Alarms

The device has 3 alarms.

“PRE-FILTER” alarm;

 This is a time-adjusted alarm and gives a filter replacement alarm 

after 1000 working hours under average pollution conditions.

Press and hold the “FAN SPEED” button for 5 seconds to reset this warning after you clean 

or replace the filter. Then, the warning light will off.

“HEPA” alarm;

 It is on when the hepa filter gets dirty so as to affect the device performance. 

When you change the hepa filter, the filter differential pressure sensor will detect it and the 

warning light will off.

“LAMP” alarm;

 This is a time-adjusted alarm and gives alarm after the lifetime of UV-C 

lamp (8000 hours) is expired. Press and hold the “UV-C” button for 5 seconds to reset this 

warning after you replace the UV-C lamp. Then, the warning light will off.

Summary of Contents for NEFFES NFS-1000-U

Page 1: ...USER MANUAL ...

Page 2: ......

Page 3: ...ccumulate inside the device and generate a pungent and hazardous substance under certain circumstances l l Don t sit or stand on the device or shake it Otherwise the device may breakdown l l Don t use the device to remove toxic substance such as carbon dioxide and silicon gas l l Don t use the device at heavily smoky or dusty place e g kitchen or where flammable gases or metal dusts may be present...

Page 4: ...y cause electric shock or damage l l Avoid bending stretching or placing objects on the power cable which may damage it l l Do not use damaged power cords or deformed plugs Using damaged power cords or plugs may cause short circuit electric shock or fire l l If the power cord is damaged it must be replaced to avoid dangerous situations l l Disconnect the device from power supply if you are not to ...

Page 5: ... controlled EC motor fans The EC motors incre ase the energy efficiency of the device providing energy savings The fan can be operated at 5 different speeds via the control panel The Neffes Air Purifier has a 4 stage filtration system The antimic coated cassette type pre filter has a high dust holding capacity It can be easily replaced thanks to its washable and sliding system HEPA filters can tra...

Page 6: ...Panel 2 Reflective Sheet 3 Pre Filter 4 Hepa Filter 5 UV C Lamp 6 Activated Carbon Filter 7 Blowing Nozzles 8 Fan 9 Casing 10 Air Intake Grill Package Content Ready to use Neffes air purifier Use and Maintenance Manual Power cable DESCRIPTION OF COMPONENTS ...

Page 7: ...n their boxes They should be stacked vertically side by side If the devices are to be handled in a verti cally stacked position the maximum number of devices to stacked on top of each other should be maximum 3 for NFS 400 U model and 2 for NFS 1000 U During storage the devices should be protected from external weather conditions and should not be placed on a damp and wet ground LAYOUT AND INSTALLA...

Page 8: ...he filters must be completely attached to the device after a cleaning or replacement operation The filters must be replaced by the service Always disconnect the device from power supply before a filter cleaning or replacement operation Always use a protective gloves and mask when replacing the filters Do not dispose them with domestic wastes The waste filters must be disposed safely Ask for help f...

Page 9: ...h bag and tightly sealed The date and time of this process should be written on the bag with a non erasable pen After 72 hours the bag containing the filter can be disposed with domestic wastes However if the filters are not subjected to this process they should be regarded as medical waste and disposed accor dingly Make sure that the new hepa filter is properly fit in the filter frame Otherwise t...

Page 10: ... if the button is pressed once the fan speed will switch to the 1st stage When the device works again after a power outage it will resume the previous mode 3 Alarms The device has 3 alarms PRE FILTER alarm This is a time adjusted alarm and gives a filter replacement alarm after 1000 working hours under average pollution conditions Press and hold the FAN SPEED button for 5 seconds to reset this war...

Page 11: ...r case After a while after the device works the smell will gradually decrease and then disappear The filters have not been cleaned replaced for a long time Clean replace them The UV C lamp does not work Was the UV C lamp activated by pressing the UV C button Press the UV C button to activate the lamp The UV C lamp was inserted to holder properly Make sure that the UV C lamp was properly inserted t...

Page 12: ...B Ayazaga Ticaret Merkezi Kat 12 34398 Maslak Istanbul Turkey T 90 212 286 08 73 E mitsubishiform formgroup com Pancar Organize Sanayi Bolgesi 7 Cadde No 13 Ayrancilar Torbali Izmir Turkey T 90 232 864 21 00 E formfabrika formgroup com 2020 09 11 000 İSTANBUL Eski Büyükdere Caddesi Sümer Sokak No 1B Ayazağa Ticaret Merkezi Kat 16 Maslak 34398 İstanbul Turkey T 90 212 286 18 38 F 90 212 286 66 48 E...