forlong DRT-370D User Manual Download Page 3

DRT-370D user manual

Shanghai Fengyilong Electronic Co. Ltd.

www.china-meters.com

-3-

Email:[email protected]

m

021-60975591/ 60975592

¾

Never break the seals and open the front cover as this might influence the functionality
of the meter, and will void any warranty.

¾

Do not drop, or allow physical impact to the meter as there are high precision

components inside that may break or render the meter measures inaccurate.

Exclusion of liability

We have checked the contents of this publication and every effort has been made to

ensure that the descriptions are as accurate as possible.

However, deviations from the description cannot be completely ruled out, so that no
liability can be accepted for any errors or omissions contained in the information
given. The data in this manual are checked regularly and the necessary corrections

are included in subsequent editions. We are grateful for any improvements that you

care to suggest.

Subject to technical modifications without notice.

Copyright

Copyright Forlong January 2011 All rights Reserved.

It is prohibited to pass on or copy this document or to use or disclose its contents

without our express permission. Any duplication is a violation of the law and subject
to criminal and civil penalties. All rights reserved, particularly in the event of a

patent award or utility model registration.

1.2 Foreword

Thank you for purchasing the Forlong DRT-370D DIN rail three phase four wire

energy meter. The Forlong DRT-370D energy meter is the most advanced type
electronic kWh meter available at the market. With the Forlong product range we

have introduced a large scale of energy meters on the market suitable for 110V AC
to 400V AC (50 or 60Hz). Besides the normal energy meters we also developed our

own pre-paid meters with chip card, chip card re-loaders and a complete PC
management control system. For more information on other product please contact

our sales department at [email protected] or [email protected].

Although we produce the Forlong DRT-370D meter according to IEC 62053-21 and
our quality inspection is very accurate there might always be a possibility that your

product shows a fault or failure for which we do apologize. Under normal conditions
your product should give you years of benefit and pleasure. In case there is problem

with the energy meter you should contact your dealer immediately. All energy
meters are sealed with a special seal. Once this seal is broken there is no possibility

to claim for warranty. Therefore NEVER open an energy meter or break the seal of
the energy meter. The warranty time is 6 months, after production, and only valid

for construction faults.

Summary of Contents for DRT-370D

Page 1: ... meters com 021 60975591 60975592 DRT 370D DIN rail three phase four wire energy meter User manual 1 1 Safety instruction 1 2 Foreword 1 3 Performance criteria 1 4 Specifications 1 5 Basic errors 1 6 Description 1 7 Dimensions 1 8 Installation 1 9 Operating 1 10 Troubleshooting 1 11 Technical support ...

Page 2: ...ion start up ground and label devices systems and circuits according to safety and Regulatory standards Use for the intended purpose The equipment device module may only be used for the application cases specified in the catalog and the user manual and only in connection with devices and components recommended and approved by DMMetering Proper handling The prerequisites for perfect reliable operat...

Page 3: ...and civil penalties All rights reserved particularly in the event of a patent award or utility model registration 1 2 Foreword Thank you for purchasing the Forlong DRT 370D DIN rail three phase four wire energy meter The Forlong DRT 370D energy meter is the most advanced type electronic kWh meter available at the market With the Forlong product range we have introduced a large scale of energy mete...

Page 4: ... 300 520V AC 3 Insulation capabilities AC voltage withstand 4KV for 1 minute Impulse voltage withstand 6KV 1 2µS waveform Starting current Ist 0 04A Transitional current Itr 1 0A Minimum current 0 5A Reference current Iref 10A Maximum current Imax 100A The current measuring range 0 5 10 100 A Peak current withstand 3000A for 0 01s Operational frequency range 50Hz 10 Internal power consumption 2W 1...

Page 5: ... meters com 021 60975591 60975592 1 6 Description A Front panel B Cover C Base D Protection Cover E Security hasp Material Front panel PC inflammable retarding Protection cover ABS PC alloy inflammable retarding Cover ABS PC alloy inflammable retarding Base ABS PC alloy inflammable retarding A B E D C ...

Page 6: ...ent device used in the circuit An external switch or a circuit breaker should be installed on the inlet wire which will be used as a disconnection device for the meter And there it is recommended that the switch or circuit breaker be near the meter so that it is convenient for the operator The switch or circuit breaker should comply with the specifications of the building electrical design and all...

Page 7: ...e the green LED represent L2 phase the red LED represent L3 phase When any phases work normally the LED representation will burn When any phases have failure or no power the LED will turn off Consumption indication There is a PULSE LED which is used as indicating power consumption in the front panel of DRT 370D When consumption happens the LED will flash The more quickly LED flash the more consump...

Page 8: ... impulse output connect 5 27V DC to connector 20 anode and the signal wire S to connector 21 cathode The meter pulses 800 per kWh 1 25Wh imp 1 10 Troubleshooting CAUTION During repairing and maintenance do not touch the meter connecting clamps directly with your bare hands with metal blank wire or other material as you will have the chance of an electricity shock and a possible chance for health d...

Page 9: ...ws on the L1 L2 L3 and N Make sure all screws are fixed Than there should be a 230V 50Hz AC voltage between the terminal screws on the N and L1 or L2 or L3 when power supply is input Please contact technical support to replace this meter No light for the consumption indicator PULSE SOLED Is the load running Is the operating power too low Only when load is running this LED will flash If the operati...

Page 10: ...r can t run Please contact technical support to replace this meter No pulse output Is DC power supply connected to the meter Is the connection correct Maybe there is a fault in the Check the external voltage source Ui is 5 27V DC Check correct connection connect 5 27V DC to connector 20 anode and the signal wire S to connector 21 cathode Please contact technical support to replace this meter Pulse...