Stationary pump installation
1.
The pump must be placed on an even surface in the bottom of a well or a tank.
2.
To enable appropriate operation and maintenance of the pump in safe conditions,
observe minimum required spacing between walls and other elements when
placing the pump.
3.
It is recommended to use pipes and connectors of the same size in the whole
water system.
4.
It is recommended to use non-return valve behind connector pipe of the pump.
5.
Dimensions of well for the pump should be minimum 65 x 65 x 50 cm so the float
switch can move there freely.
Connecting to electrical power supply
Submersible pump is equipped with breakdown resistant plug. In accordance with valid
regulations, the pump allows connecting to safe socket of power network with parameters:
230 V AC, 50 Hz. Connect the pug of the power cable only to mains socket with protective
prong that is connected to electrical circuit with residual current protection I∆N<30mA or I∆N
= 30mA).
WARNING!
In case the power cable or its plug are damaged, it is forbidden to repair those
parts by one’s own means. Entrust repair of power cord and the plug only to a qualified
person. Only original parts should be used.
Operation / settings
Switching on / switching off
Before connecting the pump to a power supply network, always check that mains voltage
matches the voltage shown on the rating plate that is fixed to the pump, and that switch is in
the off position.
Checking settings of the pump switching on/off
Float switch controls switching the pump on and off. Before starting the pump, check the
following:
1. Float switch should be installed so it can easily access triggering levels (of and off)
with little force. To check, place the pump in a vessel filled with water. Lift the float
switch (2) manually, next lower it. Doing so, note position when the pump switched
on and o
ff (fig. А and В).