FM8(P) & FM10(D/T/TW/P)
18
Periodically check oil level to ensure it is between the 2 grooves
around the Dipstick. When the oil level reaches the lower groove, oil
refilling is required. We recommend using ISO 46 grade hydraulic
fluid, sometimes labelled as #46 grade oil.
Maintenance
REPLACING THE HYDRAULIC OIL
Replace the Hydraulic oil in the log splitter
after every 150 hours of use as follows.
•
Make sure all moving parts stops and
the log splitter is unplugged.
•
Unscrew Oil Drain Bolt with Dipstick to
remove it.
•
Tip the log splitter onto the Support Leg
end over a 4 litres capacity container to
drain the hydraulic oil off.
•
Tip the log splitter onto the motor end.
•
Refill with fresh hydraulic oil to the
volume given for a particular model in
technical specifications table.
•
Clean the surface of Dipstick attached
to the Oil Drain Bolt and put it back into
the oil tank while keep the log splitter
vertical.
•
Make sure the level of the refilled oil
is no more than 10mm above the 1st
groove on the dipstick.
•
Clean the Oil Drain Bolt threads before
re-inserting. Make sure it is tightened
to avoid leakage before placing the log
splitter horizontal.