Fordia ELEPUMP KF-50M Series Use And Maintenance Manual Download Page 10

ENGLISH

25

Dimensions (in mm)
Belt section as per 

DIN symbol

DIN 7753 part 1 and B.S. 3790 

symbol B.S./ISO

Belt section as per 

DIN symbol

DIN 2215 and B.S. 3790 

symbol B.S./ISO

XPB/SPB

SPB

17

B

XPC/SPC

SPC

22

C

Pitch width

b

w

14.0

19.0

Increased grooving width b

1

 ≈

α = 34°

18.9

26.3

α = 38°

19.5

27.3

c

8.0

12.0

Distance between grooving

e

23 ± 0.4

31 ± 0.5

f

14.5 ± 0.8

20.0 ± 1.0

Increased grooving depth

t

min

22.5

31.5

α

34°

by primitive diameter

d

w

from 140 to 190 from 224 to 315

38°

narrow-section V-belts 

DIN 7753 part 1

> 190

> 315

α

34°

by primitive diameter

d

w

from 112 to 190 from 180 to 315

38°

classic section V-belts 

DIN 2215

> 190

> 315

Tolerance for α = 34°-38°

± 1°

± 30’

Pulleys for b2 by grooving number z

b2 = (z-1) e + 2 f

1

29

40

2

52

71

3

75

102

4

98

133

5

121

164

6

144

195

7

167

226

8

190

257

9

213

288

10

236

319

11

259

350

12

282

381

Minimum pulley diameter must be respected.

Do not use laminated V-belts.

Fig. 9

b)  Use high performance belts – for example 

XPB 

instead of 

SPB 

– as a lower quantity of belts for the same transmitted 

power may be necessary and a consequent shorter 

resulting distance compared to the shaft shoulder (P.T.O) 

“a“ of Fig. 10.

Shaft shoulder

(P.T.O.)

Fig. 10

c)  Pull the belts according to manufacturer instructions. 

Excessive pulling can cause reduced bearing life and wear 

out the pulley prematurely. Pulling depends on different 

variables as indicated in point. 9.11.

d)  Belt length has a natural tolerance ≥ ± 0.75%. For this 

reason, the 4 belts must be purchased as a pair.

e)  Follow the direction of the belt pull as shown in Fig. 9 for 

other needs, contact our 

Technical

 or 

Customer Service 

Departments

.

f)  Take care of the alignment of the driving pulley and driven 

pulley grooves.

Summary of Contents for ELEPUMP KF-50M Series

Page 1: ...Manuale uso e manutenzione Use and Maintenance Manual Manuel d utilisation et d entretien Betriebs und Wartungsanleitung Manual de Uso y mantenimiento Manual de uso e manuten o Serie KF 50M...

Page 2: ...ended 20 8 PORTS AND CONNECTIONS 21 9 PUMP INSTALLATION 22 9 1 Installation 22 9 2 Rotation direction 22 9 3 Version change 22 9 4 Hydraulic connections 22 9 5 Pump supply 22 9 6 Suction line 23 9 7 O...

Page 3: ...ates must be clearly marked and prohibited to unauthorised personnel and wherever possible restricted or fenced Personnel authorised to access this area should first be instructed how to operate withi...

Page 4: ...carried out by authorised personnel using appropriate equipment in order to prevent damage to components in particular to connections 4 Always only use original spare parts to ensure total reliabilit...

Page 5: ...1 instrumentation A final detection of sound pressure must be performed on the complete machine system Should the operator be located at a distance of less than 1 metre he will have to use appropriate...

Page 6: ...s cSt Viscosity Ambient temp C The used oil must be placed in a suitable container and disposed of in special centres It absolutely should not be discarded into the environment 8 PORTS AND CONNECTION...

Page 7: ...e RH SIDE anticlockwise Fig 5 9 3 Version change The pump version is defined as right when Observing the pump facing the head side the pump shaft must have a PTO shank on the right side The pump versi...

Page 8: ...suction 8 Provide for proper guards inside the tank to prevent that bentonite flow from the bypass and the tank supply line can create vortexes or turbulence near the pump supply pipe port 9 Make sur...

Page 9: ...exceed 7500 N value necessary for Layout definition The transmission is considered adequate if the load is applied to a maximum distance a 40 mm from the shaft shoulder P T O as shown in Fig 10 For di...

Page 10: ...164 6 144 195 7 167 226 8 190 257 9 213 288 10 236 319 11 259 350 12 282 381 Minimum pulley diameter must be respected Do not use laminated V belts Fig 9 b Use high performance belts for example XPB...

Page 11: ...s connected and pressurised see par 9 4 9 5 9 6 and the graphs in par 9 8 1 The suction line ensures a hermetic seal over time 2 Any shut off valves between the supply source and the pump are fully op...

Page 12: ...tee will in any case be invalidated if a The pump is used for purposes other than for those agreed upon b The pump is fitted with an electric or combustion motor with performance exceeding those indic...

Page 13: ...2016 01 Fordia All rights reserved EXPLODED DRAWING AND PART LIST...

Page 14: ...010 D 4 18 O ring 1 549 ID X 0 103 CS KF40 KF50M 31 101 007 B 3 19 Plug cap valve KF50M 31 112 012 3 20 Cover valve plate KF50M 31 112 023 1 21 Bolt M12 X 35 UNI 5737 KF50M 31 112 024 12 22 Piston sup...

Page 15: ...0M 31 101 077 1 47 Connecting rod screw KF40 KF50M 31 101 016 6 48 Connecting rod KF40 KF50M 31 101 021 3 49 Connecting rod bearing KF40 KF50M new s 31 101 060 E 3 49A Connecting rod bearing 0 25mm KF...

Page 16: ...fied above meets all the essential safety and health protection requirements as listed in section 1 of Annex I of the Machinery Directive and the relevant technical documentation has been compiled in...

Page 17: ...nur mit vorheriger schriftlicher Genehmigung des Copyright Inhabers elektronisch kopiert zur G nze oder teilweise reproduziert oder in jeglicher Form an Dritte weitergegeben werden d rfen Bei Verst e...