PUMP DRAIN PLUG
(CLEAN OUT PORT)
13
OPERATION
Draining Pump Chamber (See Fig
•
Remove Drain Plug and drain Pump Chamber.
•
Remove Filler Cap and flush Pump Chamber with clean, fresh water.
•
Let Pump Chamber drain again.
•
Reinstall Filler Cap.
•
Reinstall Drain Plug.
FIG 10
This section of the manual includes a maintenance schedule, routine inspection procedures, and basic maintenance
procedures using basic hand tools. Some complex service procedures require special tools and are best handled by a
qualified service technition. Regular maintenance will extend the life of this water pump and improve its performance.
The warranty does not cover items that result from operator negligence, misuse, or abuse. To receive full value from the
warranty, operator must maintain the water pump as instructed in this manual, including proper storage.
Before inspecting or servicing this machine, make sure the engine is off and no parts are
moving.
WARNING!
Pre-operation Steps
Before starting the engine, perform the following pre-operation steps:
•
Check engine oil level and the fuel tank level.
•
Make sure the air filter is clean. Remove any debris that has collected on the water pump.
•
Check all gaskets and hoses for kinks and damage. Make sure all hose connections are secure.
•
Provide any necessary maintenance.
•
Inspect the work area for hazards.
Remove Debris
•
Clean any debris that has collected around or behind the muffler, recoil starter, and controls.
•
Use a damp cloth to wipe exterior surfaces. If dirt is caked on, use a soft bristle brush.
After Each Use
Follow the following procedure after each use:
•
Shut off engine.
•
Drain Pump Chamber
•
Store unit in a clean and dry area.
13
Recommended Maintenance Schedule
Engine Oil
Air Filter
Fuel Filter
Oil Filter
Fuel Tank
Check Level
Replace
Check
Clean
Replace
Replace
Clean
Each Use
O
O
Every Month or
Each 20 Hrs
Every 3 Month or
Each 50 Hrs
Every 6 Month or
Each 100 Hrs
Every 12 Month or
Each 300 Hrs
O(First Use)
O
O
O
O
O
Verify Fuel Level