Ford FG7750PBE Operator'S Manual Download Page 6

6

Improper treatment of generator can damage the unit and shorten it’s life.

Always repair this unit as specified in this manual. If you have any questions contact your dealer or consult a qualified

Shut generator off if electrical output is missing, unit vibrates excessively or begins to smoke, spark or emit flames.

service center.

WARNING!

Do not bypass any safety device.  Moving parts are covered with guards. Make sure all protective covers are in place.

Never transport or make adjustments to this unit while it is running.

Never insert objects through cooling slots.

WARNING!

Never operate this unit if there are any broken or missing parts and only use Ford Power

Equipment replacement parts specifically designed for this unit.

Only use this unit as intended or serious injury or death could result.

SAFETY RULES

Increasing governing speed is dangerous which can result in personal injury and / or damaged equipment.

Decreasing governing speed adds an excessive load and can damage equipment.

Only when operating at the preset governing speed will this generator will supply the correct rated frequency and 

voltage.

WARNING!

Never modify this unit in any way or modify governed speed.

Only operate generator on a level surface.

Always connect the nut and ground terminal on the frame to an appropriate ground source.

WARNING!

Generator must be properly grounded to prevent electrocution.

Never handle the generator, electronic devices, or any cord while standing in water, while barefoot, or when hands 

or feet are wet.

Always keep the generator dry. Never operate generator in rain or under wet conditions.

Use a ground fault circuit interrupter (GFCI) in a damp or highly conductive area, such as metal decking or steel 

work.

Never plug electronic devices into generator having frayed, worn, or bare wires. Never touch bare wires or make 

Never permit a child or unqualified person to operate generator. Keep children a minimum of 10 feet away from the

contact with receptacles.

generator at all times.

If using the generator for back up power, notify the utility company.  

If connecting generator to a building’s electrical system for standby power, you must use a qualified electrician to 

install a transfer switch. Failure to isolate the generator from the power utility could result in serious injury or death to 

electric utility workers.

WARNING!

This generator produces a very high voltage which could result in burns or 

electrocution causing serious injury or death.

PROP 65 WARNING: 

This product contains chemicals known to the state of California to cause cancer and birth defects or 

other reproductive harm.

Summary of Contents for FG7750PBE

Page 1: ...ww fordpower cc OPERATOR S MANUAL MODEL FG7750P E B ITEM Warning The Engine Exhaust from this product contains chemicals known to the State of California to cause cancer birth defects or other reprodu...

Page 2: ...or to an Electrical System 13 Operation 14 How to Stop Engine 15 Grounding the Generator How to Start Engine 14 Receptacles and Extension Cords 15 Don t Overload Generator 16 Wattage Reference Guide 1...

Page 3: ...e warranty assistance or other services inquiries you can contact us by internet at www fordpower cc The emissions control system for this generator is compliant with all standards set by the U S Agen...

Page 4: ...serious injury avoid attempting to lift the generator alone WARNING Safety Instructions Using a generator indoors WILL KILL YOU IN MINUTES Carbon monoxide gas is a poisonous odorless gas that can cau...

Page 5: ...If unit has been running then the fuel cap is under pressure remove slowly To keep fuel from spilling secure unit so it cannot tip while operating or transporting When transporting unit disconnect the...

Page 6: ...nerator on a level surface Always connect the nut and ground terminal on the frame to an appropriate ground source WARNING Generator must be properly grounded to prevent electrocution Never handle the...

Page 7: ...Circuit Breaker C Hour Meter D Circuit Protectors E A B Two 120 V GFCI duplex Receptacles 120 240 Volt AC 30 Amp twist lock receptacle NEMA L14 30 120 Volt AC 30 Amp twist lock receptacle NEMA L5 30...

Page 8: ...ever L Air Filter M Handles Grips N Oil Drain Plug O Support Leg Foot P Fuel Tank Q Fuel Fill Cap R Fuel Valve ON OFF T Oil Fill Dipstick U Battery V No Flat Foam Filled Tires P Q S Recoil Starter Gri...

Page 9: ...or 4 Leave generator on box to install wheel assembly Packing List Check all loose parts to the following list Contact your dealer if any loose parts are not included Description Qty Generator 1 Quick...

Page 10: ...g screws Raise or tilt generator so you can slide the wheel axle pin into the wheel the washer the wheel mounting hole located on the side of the frame Secure the wheel assembly by reinserting a hair...

Page 11: ...hen removing the battery for replacement Remove the nut and bolt first from the negative Black post then from the positive Red post being careful not to short across the terminals Always abide by the...

Page 12: ...r If you get electrolyte contact with your eye rinse immediately with clean water and seek medical attention NOTICE If the Generator is stored for over six months the battery will need to be removed a...

Page 13: ...ath to electric utility workers WARNING This generator produces a very high voltage which could result in burn or electrocution causing serious injury or death Connecting Generator to an Electrical Sy...

Page 14: ...d to connect generator to a driven ground rod Connect the ground terminal to the driven ground rod with a No 8 AWG American Wire Gauge copper wire The wire connects to the terminal between the lock wa...

Page 15: ...is equipped with the following receptacles 120 Volt AC 20 Amp receptacle Two 120 V GFCI duplex Receptacles 120 240 Volt AC 30 Amp twist lock receptacle NEMA L14 30 This receptacle has a 20 Amp push to...

Page 16: ...nd surge watts for all electronic devices connected to the generator Rated watts refer to the power a generator must supply to keep a device running Surge watts refer to the power a generator must sup...

Page 17: ...0 2000 Electric Drill HP 5 4 Amps 600 900 Hammer Drill 1000 3000 Air Compressor 1600 4500 Other Home Security System 500 500 Garage Door Opener HP 750 750 Essentials Rated Watts Surge Watts 75W Light...

Page 18: ...o prevent icing take the following steps 1 Replace any old fuel with clean fresh fuel 2 Use synthetic 5W 30 or SAE 5W 30 engine oil Check oil daily or after every 8 hours of use 3 Turn fuel valve to t...

Page 19: ...Store unit in a clean and dry area WARNING After First 5 Hours Change Oil After 8 Hours or Daily Clean Debris Check Engine Oil Level Annually 25 hr Use Check and Clean Air Cleaner Change Engine Oil S...

Page 20: ...res determine the proper oil viscosity for the engine Use the chart to select the best viscosity for the outdoor temperature range expected Carefully add SAE 10W 30 to empty reservoir until the oil re...

Page 21: ...Equivalent To clean remove the air filter cover Carefully pull the air filter out by lifting up along the edges Remove dirt from filter by tapping on it or having it blown out Replace with new filter...

Page 22: ...empty if needed or inspect filter prior to fill up CAUTION Draining Fuel Tank and Carburetor To help prevent gum deposits in the fuel system drain the fuel from the tank and carburetor before storing...

Page 23: ...owly pull the recoil Starter until you feel the engine build compression When you feel resistance Leave the Engine in this state as this will prevent any corrosion on the cylinder walls if stored for...

Page 24: ...fuel 8 Fuel valve is in OFF position 9 Over choking 10 Low oil level 11 Rich fuel mixture 12 Intake valve stuck open or closed 13 Loss of engine compression 14 Dead battery 15 Engine has flooded 1 Tur...

Page 25: ...DIAGRAMS 25...

Page 26: ...coverage on generator engine and alternator components parts only 24 Month Limited coverage on generator engine components parts only Personal use means personal residential household use or recreati...

Page 27: ...the original receipt and product to the address found on the web site if purchased on line You can also locate your nearest Ford Power Equipment dealer for service or warranty questions by calling to...

Reviews: