![Ford F2E425E891 Operator'S Manual Download Page 13](http://html1.mh-extra.com/html/ford/f2e425e891/f2e425e891_operators-manual_2318751013.webp)
START
OPERATION
13
•
Only operate generator on a level surface.
•
Always connect the nut and ground terminal on the frame to an appropriate ground source.
WARNING!
Generator must be properly grounded to prevent electrocution.
How to Start Engine (See fig 9-16)
Fig 10
Fig 13 Electric Start
Fig 16
Fig 12
SKIP THIS IF THE
ENGINE IS WARM OR HOT.
Fig 14 Recoil Start
Fig 9
Fig 11
START
Fig 15 Remote Start
START
2
1
CHOKE
RUN
CHOKE
RUN
•
Place generator on a level surface. All electrical loads MUST be disconnected from generator.
GAS
•
Turn fuel valve to the “ON” position. (See fig 10)
•
Turn the fuel selector to “GAS” position
(See fig 11)
•
Slide the choke lever to the “Choke” position. (See fig 12) SKIP THIS IF THE ENGINE IS WARM OR HOT.
•
For electric start, Push and hold the engine START/ON/OFF switch in the “START” position. Do not hold the START/
ON/OFF switch in the “Start” position for more than 15 seconds. Allow 1 minute between starting attempts. (See fig13)
•
For manual start, turn the engine START/ON/OFF switch to the “ON” position. Pull the recoil handle (starter
cord) slowly until resistance is felt, then pull rapidly. (See fig 14)
•
For remote start, press remote control to START position. (See fig 15)
•
Let engine run for several seconds and then gradually, as engine warms up, slide the choke lever towards the “RUN”
position until the choke is fully slid to the “RUN” position. (See fig 1
6
)
•
LPG
•
Connect the gas pipe to the intake nozzle of regulator ; Open the valve of LPG bottle
(See fig 9)
•
Turn the fuel selector to “LPG” position
(See fig 11)
•
Slide the choke lever to the “Choke” position. (See fig 12) SKIP THIS IF THE ENGINE IS WARM OR HOT.
•
For electric start, Push and hold the engine START/ON/OFF switch in the “START” position. Do not hold the START/
ON/OFF switch in the “Start” position for more than 15 seconds. Allow 1 minute between starting attempts. (See fig13)
•
For manual start, turn the engine START/ON/OFF switch to the “ON” position. Pull the recoil handle (starter
cord) slowly until resistance is felt, then pull rapidly. (See fig 14)
• For remote start, press remote control to START position. (See fig 15)
•
Let engine run for several seconds and then gradually, as engine warms up, slide the choke lever towards the “RUN”
position until the choke is fully slid to the “RUN” position. (See fig 16)
Summary of Contents for F2E425E891
Page 24: ...DIAGRAMS 24...