Ford F10750E991 Operator'S Manual Download Page 18

OPERATION

Never exceed generator’s wattage / amperage capacity. This could damage the generator 
and / or connected electrical devices.

WARNING!

Check operating voltage and frequency requirements of all electrical devices prior to plugging them into the generator.

18

Bathroom

Rated Watts Surge Watts

Hair Dryer

1250

0

Curling Iron

1500

0

Family Room

Home Office

X-Box or Play Station

40

0

AM/FM Radio

100

100

VCR

100

100

Color TV (27”)

500

500

Fax Machine

65

0

Personal Computer (17” Monitor)

800

0

Laser Printer

950

0

Copy Machine

1600

0

Power Tools

1000W Quartz Halogen Work Light

1000

0

Airless Sprayer (

 HP)

600

1200

Reciprocating Saw

960

0

Circular Saw (7 ¼”)

1400

2300

Miter Saw (10”)

1800

1800

Table/Radial Arm Saw

2000

2000

Electric Drill (½ HP, 5.4 Amps)

600

900

Hammer Drill

1000

3000

Air Compressor

1600

4500

Other

Home Security System

500

500

Garage Door Opener (

 HP)

750

750

Essentials

Rated Watts Surge Watts

75W Light Bulbs

75 each

75 each

18 CU Ft Refrigerator / Freezer

800

2200

Furnace Fan (

 HP)

800

2350

Sump Pump (

 HP)

1000

2000

Water Pump (

 HP)

1000

3000

Heating/Cooling

650

800

Table Fan

Dehumidifier

800

2000

Window AC (10k BTU)

1200

3600

Central Air (10k BTU)

1500

6000

Electric Blanket

400

400

Space Heater

1800

1800

Kitchen

Blender

300

900

Toaster (2 slice)

1000

1600

Coffee Maker

1500

1500

Electric Range (1 element)

1500

1500

Dishwasher

1500

3000

Electric Oven

3410

3410

Electric Water Heater

4000

4000

Laundry Room

Iron

1200

1200

Washing Machine

1150

3400

Gas Clothes Dryer

700

2500

Electric Clothes Dryer

5400

6750

Wattage Reference Guide

(Wattages listed are just approximations. Check electronic device for actual wattage)

Power Management

Start engine without anything connected to generator.
When engine has stabilized, plug in and turn on first load. It is strongly recommended to plug in devices with the largest 
output first and the smallest output last to help prevent overloading the generator.
Allow generator output to stabilize (engine and attached devices run evenly) before plugging in the next load.

Hour Meter (See Fig 17)

The digital hour meter operates whenever the engine is running and keeps track of how many hours the unit has been used.
Use this meter along with the manual to determine when and what type of service on the unit is needed. The display will 
show the word “LUBE” at the first 25 hours of operation and again at every 100 hours of operation after.

Summary of Contents for F10750E991

Page 1: ...l FG9250E ITEM F10750E991 www fordpower cc OPERATOR S MANUAL Warning The Engine Exhaust from this product contains chemicals known to the State of California to cause cancer birth defects or other rep...

Page 2: ...ical System 13 Operation 14 How to Start Engine 14 Battery Charger for Electric Starter 15 Grounding the Generator 14 How to Stop Engine 16 Receptacles and Extension Cords 16 Don t Overload Generator...

Page 3: ...ces inquiries you can contact us by internet at www fordpower cc or write to us at The emissions control system for this generator is compliant with all standards set by the Environmental Protection A...

Page 4: ...serious injury avoid attempting to lift the generator alone WARNING Safety Instructions Using a generator indoors WILL KILL YOU IN MINUTES Carbon monoxide gas is a poisonous odorless gas that can cau...

Page 5: ...If unit has been running then the fuel cap is under pressure remove slowly To keep fuel from spilling secure unit so it cannot tip while operating or transporting When transporting unit disconnect the...

Page 6: ...nerator will supply the correct rated frequency and voltage WARNING Never modify this unit in any way or modify governed speed Never handle the generator electronic devices or any cord while standing...

Page 7: ...ON OFF Start Switch B Engine ON OFF Switch Must be ON to start engine C Hour Meter D Two 120V AC 20 Amp GFCI Duplex Receptacles E 120V 240V 30 Amp Twist Lock L14 30 F 12V DC Receptacle G Circuit Prot...

Page 8: ...Q R P T I Fuel Tank Vapor Vent J Handle K Removeable Control Panel L Choke Lever M Recoil Starter Grip N Air Filter O Support Foot P Fuel Tank Q Fuel Valve ON OFF R No Flat Foam Filled Tires S Batter...

Page 9: ...of the box being careful to avoid hitting the generator 4 Leave generator on box to install wheel assembly Packing List Check all loose parts to the following list Contact your dealer if any loose par...

Page 10: ...screws Raise or tilt generator so you can slide the wheel axle pin into the wheel the washer the wheel mounting hole located on the side of the frame and the other washer Secure the wheel assembly by...

Page 11: ...hands after touching battery WARNING Battery posts terminals and accessories contain lead and lead compounds known to cause cancer and reproductive harm NON SPILLABLE SEALED BATTERY This is a ready f...

Page 12: ...versing the previous steps Make sure the generator is outdoors in a well ventilated area while using the panel in a remote location You are now able to start and stop the unit remotely with the Electr...

Page 13: ...nnecting generator to a building s electrical system for standby power you must use a qualified electrician to install a transfer switch Failure to isolate the generator from the power utility could r...

Page 14: ...the engine START ON OFF switch in the START position Do not hold the START ON OFF switch in the Start position for more than 15 seconds Allow 1 minute between starting attempts See fig 11 For manual s...

Page 15: ...T ON OFF 1 2 ON OFF START 2 ON OFF 1 3 CHOKE RUN CHOKE LEVER WAIT 5sec OPERATION Battery Charger for Electric Starter Keep the generator battery fully charged and ready to use to avoid the need to use...

Page 16: ...en LED ON indication lights 120 240 Volt AC 30 Amp twist lock receptacle NEMA L14 30 This receptacle has a 20 Amp push to reset circuit breaker to protect against overload Each socket is rated to oper...

Page 17: ...ft or carry generator by its handle CAUTION This product is heavy and requires several people to lift Lift and lower with your legs by bending at the knees not your back to avoid injury Don t Overload...

Page 18: ...ifier 800 2000 Window AC 10k BTU 1200 3600 Central Air 10k BTU 1500 6000 Electric Blanket 400 400 Space Heater 1800 1800 Kitchen Blender 300 900 Toaster 2 slice 1000 1600 Coffee Maker 1500 1500 Electr...

Page 19: ...nsidered fully charged when the gravity of its fluid is 1 260 or higher when measured by a hydrometer It is strongly recommended to use a hydrometer to test for battery charge and condition Be careful...

Page 20: ...Charger for Electric Starter pg 15 Store unit in a clean and dry area WARNING After First 5 Hours Change Oil After 8 Hours or Daily Clean Debris Check Engine Oil Level Annually 25 hr Use Check and Cl...

Page 21: ...inage plug and allow oil to drain completely Reinstall oil drainage plug tighten securely To clean remove the air filter cover Carefully pull the air filter out by lifting up along the edges Remove di...

Page 22: ...r shop Fuel tank must be empty before replacing fuel filter Run unit until tank is empty if needed or inspect filter prior to fill up CAUTION Spark Arrestor See Fig 22 Inspect the spark arrestor for b...

Page 23: ...fuel valve knob through the valve holder bracket allowing you to access the petcock When the fuel has drained from the tank close the fuel valve and reinstall fuel line securely on petcock Reinstall t...

Page 24: ...er in fuel 8 Fuel valve is in OFF position 9 Over choking 10 Low oil level 11 Rich fuel mixture 12 Intake valve stuck open or closed 13 Loss of engine compression 14 Dead battery 15 Engine has flooded...

Page 25: ...DIAGRAMS 25 FG9250E Wiring Diagram...

Page 26: ...components and labor for 90 days Proof of purchase and of maintenance must be provided Personal use means personal residential household use or recreational use by the retail consumer Commercial use m...

Page 27: ...e warranty the following services are provided to the consumer Guidance The service center will answer operational technical and maintenance questions for simple procedures that the customer feels the...

Reviews: