Krystal Enterprises
57
Braun Under Vehicle Wheelchair Lift
In the event of an electrical system failure,
the UVL system provides for full manual
operation. Locate the manual release
cable, manual down valve, and the hand
pump on the power pack.
To move platform from STOW
, pull the
manual release cable. Twist the “T” handle
to lock in the released position. The plat-
form can now be pulled outward.
To raise the platform
, make sure the
manual down valve is turned fully clock-
wise. Pump the hand pump handle until
you reach the desired platform height.
To lower the platform
, turn the manual
down valve SLOWLY counter-clockwise
to lower the platform.
To lower the front
barrier
, remove the release pin at the
barrier actuator end. Lift will not continue
operating unless release pin is re-inserted
fully.
To move platform to STOW po-
sition
, fi rst be sure the platform is at
STOW height. Pull and lock the manual
release cable. Push the platform inward to
re-engage release cable mechanism.
Emergency Back-Up Operation
Note:
Refer to Service Manual for Maintenance, Adjustment, and Trouble Shooting Procedures
Lift Closed
Lift Extended
Lift Lowered
Lift Raised
Summary of Contents for Econline Super Duty Chassis 450 1998 Series
Page 2: ...ProCarManuals com ...
Page 39: ...Krystal Enterprises 39 THIS PAGE IS INTENTIONALLY BLANK ProCarManuals com RETURN TO MENU ...
Page 95: ...Krystal Enterprises 95 95 THIS PAGE IS INTENTIONALLY BLANK ProCarManuals com RETURN TO MENU ...
Page 107: ...Krystal Enterprises 107 107 F 550 Shuttle Bus Wiring Diagram ProCarManuals com RETURN TO MENU ...