FORCE America ONE
TM
Quick Start Manual
Switch Labels
4
Switch Labels
The 5 Switch Labels always run across the very top of the screen. Each label corresponds to the
switch directly above it. Active switch functions are indicated with a green color. If a switch is
currently not used the label is left blank. The switch label will appear red if the operator selected
the Disable option on the stuck switch error condition at startup. When in this state the affected
function will not be able to be activated.
Figure 5: Switch Labels
Switch
Function
Availability Requires
Momentarily activates the Hoist, running it at
max duty cycle until the switch or interlock is
released.
Pressing both the top switch and the interlock
(integrated into the back of the controller) at
the same time will move the hoist up.
Pressing both the bottom switch and the
interlock will move it down.
The Hoist & Plow option in
calibration must be set to
Hoist or Hoist & Plow.
Momentarily activates the Plow, running it at
max duty cycle until the switch is released.
The interlock switch is not required to run
these functions.
Pressing the top switch will move the plow up
and the bottom switch will move it down.
The Hoist & Plow option in
calibration must be set to
Plow or Hoist & Plow.
Momentarily activates the Plow, running it at
max duty cycle until the switch is released.
The interlock switch is not required to run
these functions.
Pressing the top switch will move the plow left
and the bottom switch will move it right.
The Hoist & Plow option in
calibration must be set to
Plow or Hoist & Plow.
Activates or deactivates the prewet output.
Pressing the top switch will turn on Prewet
and the bottom switch will turn it off.
See page 7.
Prewet must be enabled in
Calibration.