Precarbon Filter Flushing
l
Disconnect the outlet port tube of the precarbon filter.
l
Connect a separate ¼” blue tube to the outlet port and keep the
other end of the ¼” tube at the drain facility.
l
Open the diverter valve and flush the precarbon filter till the
manufacturing debris is fully driven out and outlet water
becomes clear.
l
Close the diverter valve, disconnect the blue tubing fixed for
flushing and connect back the interconnecting tubing as earlier.
UF Membrane Flushing
l
Connect a separate ¼” white tube to the outlet port connector of
ultra filter membrane cartridge and keep the other end of the
¼” tube at the drain facility.
l
Connect the flush tube (blue tube) to the flush valve outlet port and
open the flush valve which is connected from the flush port of the
ultra filter membrane cartridge.
l
Open the diverter valve and flush the ultra filter membrane for
15 minutes continuously.
l
Close the diverter valve and close the flush valve of the product.
Note: Please don’t consume the flush water.