background image

4. Web GUI 

Status parameters of USF-111DDA-12G can be displayed on the Web display if the module is installed 
in  a  USF-212AS/USF-105AS  frame.    SNMP  monitoring  is  also  available.    Refer  to  the 
USF-212AS/USF-105AS Operation Manual for details on displaying the Web GUI window. 

 

NOTE 

USF-111DDA-12G  does  not  support  simultaneous  Web  GUI  access  from  multiple  PCs.  Use  the 
SNMP function to simultaneously monitor a USF-111DDA-12G from multiple PCs.  

 
 

4-1. WEB Display Information 

Start the Web GUI and click on a USF-111DDA-12G from slot 1 to 12 of USF-212AS/USF-105AS to 
open the window as shown below. 

 

Module Information 

 

 

Item 

Description 

Slot 

Slot no. of the USF-212AS/USF-105AS in which USF-111DDA-12G is 
installed. 

S/N 

Serial number of the USF-111DDA-12G. 

MAC Address 

MAC address of the USF-111DDA-12G. 

Firmware 

Firmware version of the USF-111DDA-12G. 

FPGA 

FPGA of the USF-111DDA-12G. 

IP Address 

IP address of the USF-111DDA-12G. 

CPU Temperature  Temperature of the CPU on the USF-111DDA-12G front card. 

Video Input 

Displays video input status. 

Detected

Normal video input. 

Not Detected

:  No video input, or input level is low. 

Input Status Trap 

Sets the SNMP trap setting when monitoring USF-111DDA-12G via SNMP 
Manager. 

Enable

:  Sends input status traps. 

Disable

:  Sends no traps. 

Input Signal 
(SD/HD/3G/12G) 

Displays the bit rate of SDI input: 

SD (270Mbit/sec), HD (1.5Gbit/sec),  

 

3G (3.0Gbit/sec), 12G (12.0Gbit/sec)

 

Not Detected

: No input signal 

Mode 

Displays the re-clock function mode. 

Output 1-11 Mute 

If not connecting video output signal via SDI OUT1-11, set 

Enable

 for 

unused ports. (Recommended use) 

Summary of Contents for USF-111DDA-12G

Page 1: ...USF 111DDA 12G Digital Distribution Amplifier 1st Edition OPERATION MANUAL ...

Page 2: ...ircuitry exposed could result in electric shock fire hazards or a unit malfunction Potential Hazards Caution If abnormal odors or noises are noticed coming from the unit immediately turn the power off and disconnect the power cord to avoid potentially hazardous conditions If problems similar to the above occur contact an authorized service representative before attempting to operate the unit again...

Page 3: ...e packing list below Check to ensure no damage has occurred during shipment If damage has occurred or items are missing inform your supplier immediately USF 111DDA 12G ITEM QTY REMARKS USF 111DDA 12G 1 USF 111DDA 12G Front Module USF 111DDA 12G Rear Module DVD ROM 1 Operation Manual PDF Screw for Rear Module Installation 4 This Product can be installed into the following frame USF 212AS USF 105AS ...

Page 4: ... 1 2 Features 5 2 Panel Descriptions 6 2 1 Front Panel 6 2 2 Rear Panel 6 3 Switch Settings 7 4 Web GUI 8 4 1 WEB Display Information 8 4 2 syslog Functions 9 5 About SNMP 10 6 Specifications and Dimensions 11 6 1 Specifications 11 6 2 External Dimensions 11 ...

Page 5: ... ASI and is capable of producing up to 11 outputs from 1 input 1 2 Features Installs into a USF 212AS USF 105AS frame 1 input 11 distribution outputs Supports SDI 12Gbps 3Gbps 1 5Gbps 270Mbps signals Automatic 12G 3G HD SD SDI equalizer and re clock functions Detection of input signal and identification of 12Gbps 3Gbps 1 5Gbps 270Mbps Supports DVB ASI 270Mbps signal SNMP monitoring and syslog supp...

Page 6: ...ED Lights green when input SDI signal is 1 5G b s 5 270Mb s LED Lights green when input SDI signal is 270M b s 6 DIP switch Sets Reclock settings 7 USB connector Used to upgrade USF 111DDA 12G software Do not connect USB devices 2 2 Rear Panel USF 111DDA 12G 6 1 2 3 SDI OUT SDI OUT 4 5 SDI IN 7 8 9 10 11 Name Description SDI IN SDI signal input Accepts an SD HD 3G 12G SDI signal SDI OUT 1 11 SDI s...

Page 7: ...g 4 OFF Do not change the setting 5 Reclock Reclock Bypass Reclock ON Normal use setting 6 ON Do not change the setting 7 OFF Do not change the setting 8 OFF Do not change the setting DS2 SW No Function Setting Factory Setting OFF ON 1 OFF Do not change the setting 2 OFF Do not change the setting 3 OFF Do not change the setting 4 OFF Do not change the setting 5 OFF Do not change the setting 6 OFF ...

Page 8: ...111DDA 12G is installed S N Serial number of the USF 111DDA 12G MAC Address MAC address of the USF 111DDA 12G Firmware Firmware version of the USF 111DDA 12G FPGA FPGA of the USF 111DDA 12G IP Address IP address of the USF 111DDA 12G CPU Temperature Temperature of the CPU on the USF 111DDA 12G front card Video Input Displays video input status Detected Normal video input Not Detected No video inpu...

Page 9: ...s to send syslog messages The IP address is the same as the SNMP trap address Refer to the USF 212AS USF 105AS Operation Manual for details on setting the SNMP trap address Facility Sets syslog logging facilities in Local 0 through Local 7 Header Message Sets syslog header messages up to a maximum of 63 alphanumeric characters Factory setting USF 111DDA 12G Input Video Detect Sets detection messag...

Page 10: ...ature degree Celsius 7 INTEGER Input Video Status usf111Dda12gInputStatus 1 cannotDetect 0 not Detected 1 detected 8 INTEGER Input SDI Bit Rate usf111Dda12gSdiRate 1 cannotDetect 0 not Detected 1 sdi SD 2 sdi HD 3 sdi 3G 4 sdi 6G 5 sdi 12G 9 INTEGER Reclock Bypass Setting usf111Dda12gReclockBypass 0 reclocking 1 reclock Bypass 10 INTEGER Output 1 11 Mute usf111Dda12gOutput1Mute 0 disable 1 enable ...

Page 11: ...I Max 100m 5C FB equivalent cable HD SDI Max 100m 5C FB equivalent cable SD SDI Max 200m 5C 2V equivalent cable SNMP SNMP Monitoring available SNMP version v2C Temperature 0 C to 40 C Humidity 30 to 90 no condensation Power 12V DC Supplied by a USF frame Power Consumption 12 7 VA 12 7W Dimensions Front module 106 W x 356 D mm Rear module 114 W x 40 7 H mm Weight 280 g Required Slots 2 Slots 6 2 Ex...

Reviews: