14
4. Operation
4-1. Power ON
After verifying that all wiring is correctly connected, apply power to the UFM frame. The
UFM-30MUX will start up and display "UFM30MUX" as shown below.
4-2. Operation and Menu Modes
4-2-1. Operation (Normal) Mode
After powering itself on, the UFM-30MUX will enter
Operation
mode and display the SDI
signal status.
If the SDI signal is normal, "
READY
" will be displayed.
If the SDI signal is abnormal, an error message will be displayed. (See the table below.)
R E A D Y
SDI status display
Description
READY
SDI signal is present.
NO SIG
No SDI signal is present.
CRC ERR
A CRC error is detected.
OP ERR
An incompatible option item is
installed.
IMPORTANT
"OP ERR" is displayed when an incompatible option module is connected to the
UFM-30MUX. Power off the frame, remove and disconnect the optional module.
To return to Operation mode