Preparation 

 
The MFR standard system is composed of the following three hardware components. 

 

Main Unit 

(hereafter 

MU

):  MFR-4000R 

 

Remote Control Unit 

(hereafter 

RU

):

 

MFR-39RU/40RU/18RU/16RU/16RUD/16RUW/32RUW/64RUW/16RUTA/39RUA/18RUA/8RUA 

 

Computer (Web Browser)

:  The MFR system setting and operation via a web browser 

 
The MFR system is connected via LAN. Network settings for MFR units are properly set prior to shipment. Operation can be 
performed immediately upon completing the following network settings and connections. Prepare the following items in the table for 
the system in advance. 
 

Items to prepare 

Computer 

For Web-based Control.  
A LAN port is required. Refer to section 2-1. "System Requirements" in the MFR Series 
Web-based Control Operation Manual" for more details. 

LAN cables 
(Cat. 5e or higher) 
 
* The supplied LAN cable 
(straight) can also be used. 

For MU and PC direct connection 

One cross-over cable 

For MU and PC connection via a hub 

Two cross-over or straight cables (*2) 

For MU and RU direct connection (*1) 

One cross-over cable 

For MU and RU connection via a hub 

Two cross-over or straight cables (*3) 

  (*1) Not available when using a redundant CPU. 

(*2) When using a redundant CPU, one more cable is required. 

  (*3) When using a redundant CPU, one more cable is required. 

 

1. LAN Connection 

(1) Set the PC IP address and subnet mask as shown below. 

IP address 

192.168.0.XXX 

XXX must be from 1 to 254 except the following numbers. 
12 and 13 (Used for MU) 

Subnet mask 

255.255.255.0 

 

(2) Connect 

the MFR-LAN

 (CPU1) port on the 

MU

 rear panel and 

MFR-LAN

 port on the 

RU

 rear panel using a LAN cable. 

*  Connect the 

MFR-LAN (CPU1)

 and 

MFR-LAN (CPU2)

 ports to the LAN, respectively, when the redundant CPU is configured. 

(3) Connect 

the PC-LAN (CPU1) 

port on the 

MU

 rear panel and the PC 

LAN

 port using a prepared LAN cable. 

 

PC-LAN and MFR-LAN must be placed in separate LAN segments (using a bridge or switch) 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

   Refer to section 2-3. "PC Network Settings" in the "MFR Series Web-based Control Operation Manual" for more details.  

 

2. Power ON 

(1) Connect the power to the MU using the supplied power cord(s). 
(2) Connect the power to the RU using the supplied AC adaptor and cable. Be sure to secure the cable with the supplied cable clip. 
(3) Power on all devices in the system. 
 

3. Open the Web-based Control Screen 

(1) Launch your web browser on the PC, enter the MFR MU address as shown below and connect to the MFR MU. 

 

http://192.168.0.12 

 

(IP address of MU PC-LAN) 

(2) Enter the following user name and password to login to the MFR Web-based Control. 
 

User name:  

user 

 

Password:  

password

 

(3) The Web-based Control screen will appear. 
 

4. Display the MU or RU Setting Page 

(1) Connected MFR system unit is displayed in the upper left corner  

of Web-based control screen. 

Unit ID: 

The current MFR system devices are displayed in the tree  
such as [100] MFR-39RU, [101] MFR-18RU, etc. 
The number displayed in square bracket such as [100] is  

Unit ID

, which also indicates the 

fourth octet 

of 

IP address

The IP address of MFR-39RU is "192.168.1.

100

" in this example. 

(2) Clicking the unit name or 

ROUTER SYSTEM SETTINGS

 toggles 

show or hide sub-menu items. 
Clicking an item in the sub-menu displays the setting page on the  
right pane. 

 

   Refer to MFR Web-based Control Operation Manual and  

MFR-RU Series Operation Manual for details. 
 

 

 
 
 
 
 
 
 
 
 

Precautions 

-  Operate the unit 

only

 at the specified supply voltage. 

Ensure

 the unit is properly grounded at all times. 

Ensure

 the power cord and connectors are firmly connected. 

Do not 

access circuitry with power applied to the unit. 

-  Unit 

should not

 be operated or stored with the cover, panels, 

and/or casing removed. 

-  Unit s

hould not

 be operated or stored in a humid, dusty, etc. 

environment. Doing so could result in fire or electrical shock. 

 

Do not

 allow fluids, metal fragments, or any other foreign 

objects to enter the unit. If foreign matter does enter the unit, 
turn the power off and disconnect the power cord immediately. 
Remove the material or contact your authorized service 
representative. 

-  If you notice any strange smells or noises coming from the 

unit, turn the power off immediately, disconnect the power 
cord, then contact your authorized service representative. 

 

 

Packing list 
MFR-4000R: 1 
AC Cord: 1 set, CD-ROM: 1, 
Quick Setup Guide: 1 (This guide) 

https://www.for-a.com/ 

You can download manuals and other documents by registering your email address. 

 

MU (MFR-4000R) 

RU 

MFR-LAN (CPU1): 192.168.1.10/24 
MFR-LAN (CPU2): 192.168.1.11/24 

SDI OUT 

SDI IN 

Web browser 

LAN cable 

Button operation 

 

GUI Operation 

 

HUB 

HUB 

PC-LAN (CPU1): 192.168.0.12/24 
PC-LAN (CPU2): 192.168.0.13/24 

LAN cable 

MFR-LAN 

Click here to open 
the menu tree. 

Unit ID is indicated in 
square brackets [   ]. 
 

Click an item to open 
the setting page on 
the right pane. 