3. Replacing Power Supply Units 

3-1. Removing the Front Panel 

Loosen the two screws on the front panel as shown below, then remove the panel. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

3-2. Removing a Power Supply Unit 

1) 

Loosen the two screws securing the power unit (with problem) as shown below.  

2) 

Grasp gently pull the  broken power supply unit, grasping the screws, straight out, until it is 
completely removed from the unit. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

3-3. Installing a Replacement Power Supply Unit 

1) 

Unpack the replacement power supply unit from its packing.  

2) 

Align and carefully insert the power supply unit into its slot. 

3) 

Make sure the unit is inserted completely and properly, then tighten the screws on both sides. 

 

Screw 

Screw 

POWER1 Screw 

POWER2 Screw 

Summary of Contents for HVS-49PSM

Page 1: ...HVS 49PSM Redundant Power Supply Unit for MU 1st Edition INSTALLATION GUIDE...

Page 2: ...operation manual thoroughly to ensure you understand the product Afterwards store this manual in a safe place for future reference Check your received items against the packing list below Packing List...

Page 3: ...oving the Power Supply Slot Blank Panel 4 2 3 Installing the Redundant Power Supply Unit 5 2 4 Reinstalling the Front Panel 5 3 Replacing Power Supply Units 6 3 1 Removing the Front Panel 6 3 2 Removi...

Page 4: ...requires accessing the unit interior by opening the panel should only be done by qualified technical personnel Power should be turned OFF and all power cords disconnected from the unit before perform...

Page 5: ...elow 2 4 Reinstalling the Front Panel 1 Return the front panel onto the front of the unit then tighten the two screws from Section 2 1 Removing the Front Panel above 2 Connect the AC cords then turn b...

Page 6: ...wn below 2 Grasp gently pull the broken power supply unit grasping the screws straight out until it is completely removed from the unit 3 3 Installing a Replacement Power Supply Unit 1 Unpack the repl...

Page 7: ...m Section 3 1 above 2 Connect the AC cords then turn both of the power supply switches on 3 Verify that the power indicator POWER LED is lit green while ALARM LED is unlit IMPORTANT Contact your sales...

Page 8: ...y Tel 39 039 916 4811 Fax 39 039 878 140 FOR A UK Limited Trident Court 1 Oakcroft Road Chessington KT9 1BD U K Tel 44 0 20 3044 2935 Fax 44 0 20 3044 2936 FOR A Italia S r l Via Volturno 37 20861 Bru...