![FOR-A HVS-100PSM Installation Manual Download Page 10](http://html1.mh-extra.com/html/for-a/hvs-100psm/hvs-100psm_installation-manual_2316718010.webp)
10
3. Checking Operation
3-1. Power ON
(1) Connect two power cords to supply power to the switcher. Turn on both power switches.
(2) Verify that the power indicator on the front panel lights green and the alarm indicator is turned
off.
IMPORTANT
The alarm indicator blinks red when an alarm occurs. In such case, power off the
system and consult your FOR-A supplier.
3-2. Checking the Status Menu
Follow the procedure below to verify that the HVS-100PSM is properly installed.
(1) The MENU button on the control panel should blink when powered ON.
(2) Press MENU, then press SETUP.
(3) The SETUP menu top page appears in the menu display. Turn F1 to select STATUS and
then press F1.
SETUP :>SYSTEM >INPUT >OUTPUT >PANEL
MENU :>GPI/TLY >FUNCTION>EXT I/F >
STATUS
(4) The [SETUP - STATUS] menu as shown below appears. Turn F1 to select ALARM and then
press F1.
SETUP :>
ALARM
>VERSION >OPTION
STATUS :
(5) The [SETUP - STATUS - ALARM] will appear. Verify that "NOR" is displayed for MU PS2
(HVS-100PSM).
STATUS :FAN1: NOR FAN2: NOR : 1/3
MU ALARM: PS1: NOR
PS2: NOR
:
3-3. Affixing the Supplied Label
Affix the supplied label (with serial number) as shown below on the rear panel.
REF OUT
1
1
2
3
4
5
6
7
8
2
3
4
A
B
C
REF IN
1
2
2
AC100-240V 50/60Hz IN
AC100-240V 50/60Hz IN
1
TO OU
LAN
GENLOCK
SDI INPUT
RS-422
GPI IN/TALLY OUT
HDMI OUT
AUX
Label