FC-ONE-SETUPGUIDE-E-1.DOCX 

FC-ONE 

Quick Setup Guide 

 

1. Connection and System Configuration 

 

 

Installing the AC Cord Retaining 
Clip 

 
1) 

Insert the anchor into the hole next to the AC inlet. 

2) 

Plug in the AC cord. 

3) 

Adjust the strap length to fit. 

4) 

Wrap the AC cord clamp around the AC cord. 

5) 

Gently pull on the AC cord to ensure it has been securely  

 

plugged in. 

 
 
 
 
 
 

 

 
FC-ONE units accept 4 video inputs, select one of them for correction 
and distribute the corrected video signal to all 4 outputs (SDI OUT1-4). 
 
 

2. Setup Procedure 

 
The procedure is shown numbered in the above figure. 
 
1  Apply DC power to the FC-ONE using the supplied AC cord. Secure the cord with the supplied AC cord retaining clip. Ground the unit for your safety. 
2  Connect monitors and/or recorders to the SDI OUT connectors. 
3  Connect signal source devices such as video cameras and/or switchers, to the SDI IN connectors. 
4  Connect a PC to be used for remote control to the FC-ONE LAN connector using a LAN cable. 
5  Turn the power of the FC-ONE on. When the FC-ONE is powered on, all LEDs on the front panel, including Alarm indicators, light. Once startup is complete, 

current status will be indicated. 

 
After a setting change, do not turn the unit power off for at least 10 seconds. The setting data may otherwise not save properly. 
Complete connections before turning the power of the unit on. 
 
6  Change the PC network settings for the connection with the FC-ONE. Go to Local Area Connection > Properties > Internet Protocol (TCP/IP)> Properties, then 

set the IP address and Subnet mask to match that of the FC-ONE. 

 

 

PC IP address 

192.168.0.xxx

  (xxx is any number from 1 to 254 except for the number set for the FC-ONE unit and gateway number.) 

 

 

Subnet mask Set to   

255.255.255.0.

 

192.168.0.30 

is the default IP address. 

 
7  Install the software (FC-ONE Windows GUI).  

 
<To start up Windows GUI> 

Open the CD-ROM, and the FC-ONE GUI folder. Double-click the 

Setup

 icon to start the setup wizard. Once the GUI starts up and a GUI page opens, enter the 

FC-ONE IP address to register the unit. Click a number under Select to select a unit, then click 

Connect

 to establish a connection with the FC-ONE. 

3. Front Panel Indicators 

 

 

No 

Item 

Description 

Power switch 

Used to turn the unit ON / OFF. 

Unit status 
indicators 

DC POWER 
1/2 

Lit green 

Power supply is normal. 

Lit red 

A power failure has occurred. 

FAN 
ALARM 

Lit green 

All fans are operating normally. 

Lit red 

One or more fans have failed. 

GENLOCK 

Lit green 

Genlock signal input is present. 

Unlit 

No genlock signal input is present. 

SDI IN status 
indicators 

BY-PASS 

Lit green 

Input signal is being bypassed. 

Unlit 

No signal is being bypassed. 

VIDEO 

Lit green 

Video signal input is present. 

Unlit 

No video signal input is present. 

AUDIO 

Lit green 

Embedded audio signal is present. 

Unlit 

No embedded audio signal is present. 

INITIALIZATION  
button 

Used to reinitialize the unit. Read the WARNING below before proceeding.  
To reinitialize the unit, turn the unit on while holding down the INITIALIZATION 
button. Continue pressing the button until a short beep will sound. The 
initialization will take about 10 seconds. 

 

All setting data will be reset. Back up before executing a reinitialization. 

 

Precautions 

-  Operate the unit 

only

 at the specified supply voltage. 

Ensure

 the unit is properly grounded at all times. 

Ensure

 the power cord and connectors are firmly connected. 

Do not 

access circuitry with power applied to the unit. 

Unit 

should not

 be operated or stored with the cover, panels, and/or casing removed. 

Unit s

hould not

 be operated or stored in a humid, dusty, etc. environment. Doing so could result in 

fire or electrical shock. 

Do not

 allow fluids, metal fragments, or any other foreign objects to enter the unit. If foreign matter 

does enter the unit, turn the power off and disconnect the power cord immediately. Remove the 
material or contact your authorized service representative. 

If you notice any strange smells or noises coming from the unit, turn the power off immediately, 
disconnect the power cord, then contact your authorized service representative. 

 
 
 

 
 
 

https://www.for-a.com/ 

You can download manuals and other documents by registering your email address. 

FC-ONE:

,   Quick Setup Guide: 1,   CD-ROM: 1 (Windows GUI installation disc including Operation Manuals (PDF)),  

AC cord: 2,     AC cord retaining clip: 2,     Rack mount bracket set: 1,    Rubber foot

Packing list 

 

FC-ONE-PS (Redundant Power Supply) 

Standard supply 

Reviews: