7
b)
Remove this plug by gently pulling.
c)
Fill the ICE Bank through the hole with 900mL of water using the Syringe
provided (requires 18 times filling).
d)
Place the plug back in to the hole at the top of the ICE Bank.
Caution:
Please
DO NOT
inject more than 900mL of tap water into the
ICE Bank
.
Overflowing the
ICE BANK
will cause damage to
Fontanella
.
3. Fill the Water Tank
Fill in the
Water Tank
with maximum 3 litres of the tap water (room temperature).
Please do not exceed the
MAX
line marked. Replace the
Water Tank
and its
Lid
onto
its original position. Please make sure that the
Water Tank Outlet Piston
is firmly
connected with the
Water Inlet Piston
.
Please open the left-hand side door, checking the
Control Box
. Make sure that the
Water Source Selection Switch
is turned down to “
Water Tank
” position. Therefore,
Fontanella
will only input water from the “
Water Tank
”.
Caution
: Please
DO NOT
fill more than 3 Litres of water into the
Water Tank
.
Overflow of water will damage
Fontanella
.
Caution:
To prevent the pump from working with no load and overheating, the Water
Tank should never be left without water. Otherwise, it will damage
Fontanella
.
Caution:
Although
Fontanella
can also be connected to mains water, it is
NOT
certified and therefore is
NOT
to be connected to a mains water supply in Australia.
Caution:
In places where the
Fontanella
is approved to be installed to a mains water
supply, always verify that the inlet water is of a controlled origin (drinkable). Installation
must be done strictly by a qualified technician.
Caution:
Verify that the mains pressure is between
2,0 and 3,5 bars
: in case the
mains pressure is higher than the maximum allowable value, the carbonation
procedure could be compromised (in such a case, install a pressure reducer). Should
the mains pressure be lower than the minimum value, the electrical appliance will
produce an alarm signal indicating insufficient pressure.
4. Insert CO2 Canister
Please open the left side door on the
Fontanella
and affix the
CO2 Canister.
Please
make sure the
CO2 Canister
is securely locked and firmed with the
CO2 Canister
Connector.