![Fontana Showers FS9645 Installation Instructions Manual Download Page 10](http://html1.mh-extra.com/html/fontana-showers/fs9645/fs9645_installation-instructions-manual_2315948010.webp)
Installation Of The Control Panel
1. Build the control panel into the shower panel
Step 1: Open a hole (6.7" X 3.7") on the shower panel, putting some glass cement around
the back of the control panel and fit it in the hole of the shower panel as picture shown.
Step 2: Fasten the mounting bracket onto the back of the control panel by screws.
Step 3: Install the host box on the back of the shower panel, connect the cold water and
hot water pipe, hand shower, and head shower's pipes.
1. Connect the G1/2" hot and cold water inlet pipes to the host box, tighten it and make
sure connection is well sealed (as the picture showed).
2. Connect the G1/2" water inlet pipe of the faucet to the water outlet pipe of the host box,
tighten it and make sure connection is well seated (as the picture is shown). Caution:
When installation, the hot water pipe, and the cold water pipe cannot mix up.
Otherwise, the system cannot work.
When you tighten the connector nut, torque should not exceed 8N M, GB 2.5N M is OK,
otherwise, it will damage the connector of the mixing valve and lead to water leaking.
Step 4: Connect the host box control cable with the control cable of shower faucet as an
arrow mark on the picture.
Caution: When connecting the two control cables, you must follow the arrow mark which
is shown in the cable joint. II riot, it will damage the cable joirlt.
Step 5: Connect the power supply cable of the host box with the adapter.
FontanaShowers
©
FontanaShowers
©
FontanaShowers
FontanaShowers
Customer Service: 800-684-4489
fontanashowers.com
10